Experimental study on slip performance of corroded bolted connections

被引:0
|
作者
Chen, Xiaowan [1 ]
Zhang, Fuyi [1 ]
Zhu, Zhiwen [1 ]
Gao, Jundong [2 ]
机构
[1] Shantou Univ, Dept Civil Engn & Smart Cities, Shantou 515063, Peoples R China
[2] Zhengzhou Univ, Sch Civil Engn, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
Slip resistance; Preload loss; Corrosion; Bolted connections; HIGH-STRENGTH BOLTS; CLAMPING FORCE; DAMAGE; RESISTANCE; BEHAVIOR;
D O I
10.1016/j.jcsr.2024.109049
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents a comprehensive experimental investigation into the slip performance of corroded bolted connections. A total of fifteen double-lap connection specimens were assembled and sixty fabricated load cells were employed to monitor the real-time preload of each high-strength bolt. Electrochemical accelerated corrosion tests were carried out to obtain connection specimens with five corrosion levels. The preload variations under indoor environment and during the corrosion tests were recorded, and shear tests were then performed on the connection specimens. It was found that the individual components in a connection specimen experienced different degrees of corrosion, with the bolt heads and nuts exhibiting the heaviest damage. The preload loss of high-strength bolts was maintained at a constant level with an average loss of 8.9 % after 45 days under indoor natural environment, while the preload loss induced by corrosion damage increased approximately linearly with the corrosion weight loss ratios. The slip loads and peak loads of connections with corrosion weight loss ratios of bolt set lower than 10 % displayed low sensitivity to corrosion damage, while the higher level of corrosion led to considerable declines in these characteristic loads. The experimentally determined slip coefficients were found to increase linearly with the development of corrosion weight loss ratios. Based on the experimental results, a predicted model for preload loss of high-strength bolts, calculation formulae for slip coefficients of faying surface, and consequently estimated methods for the slip resistances, were developed for corroded bolted connections.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental and numerical investigations of seismic performance of hybrid joints with bolted connections
    Pan, Zhihong
    Si, Qi
    Zhou, Zhibin
    Zhang, Yibao
    Zhu, Yanzhang
    Chen, Xudong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 138 : 867 - 876
  • [22] Experimental behaviour of bolted connections with stiffeners
    Maali, Mahyar
    Kilic, Mahmut
    Aydin, Abdulkadir Cuneyt
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2019, 12 (02): : 105 - 113
  • [23] Experimental studies on bolted glubam connections
    Yang, R. Z.
    Xiao, Y.
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (13) : 3010 - 3020
  • [24] Effect of contact surface type on the slip resistance in bolted connections
    Mahmoudi, M.
    Kosari, M.
    Lorestani, M.
    Abad, M. Jalili Sadr
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166
  • [25] PERFORMANCE OF NAILED-BOLTED CONNECTIONS
    MCLAIN, TE
    FOREST PRODUCTS JOURNAL, 1992, 42 (7-8) : 70 - 72
  • [26] Experimental study on fatigue performance of Q460 and Q690 steel bolted connections
    Guo, Hongchao
    Mao, Kuanhong
    Liu, Yunhe
    Liang, Gang
    THIN-WALLED STRUCTURES, 2019, 138 : 243 - 251
  • [27] Experimental study on low-cycle fatigue performance of high-strength bolted shear connections
    Zhang, Wenyuan
    Xie, Jingyi
    Construction and Building Materials, 2024, 447
  • [28] Slip-resistant performance and design method of novel steel one-sided bolted slip-resistant connections
    Xu, Kelong
    Yang, Lu
    Mi, Shoudu
    Han, Yawei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 222
  • [29] Study on Bond-slip Performance of Corroded Reinforced Concrete Members
    Liang, Yan
    Luo, Xiaoyong
    Ou, Ya
    Wan, Aozhou
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 1164 - 1169
  • [30] Experimental and numerical study of undersized shear panel dampers with bolted connections
    Zhao, Huatian
    Shi, Gang
    Li, Shuailing
    Zhang, Naizhou
    Zhuang, Shanxiang
    Zhu, Bin
    ENGINEERING STRUCTURES, 2023, 280