摘要
Oil-pressboard/paper insulation materials are essential in transformers for ensuring their safe and stable operation, primarily due to their roles in spatial electric field distribution and charge migration mechanisms. Current spatial distribution analyses rely on computational methods that lack empirical validation, particularly for oil-pressboard/paper composites. This study leverages the principles of the Kerr electro-optic effect to develop a rapid measurement platform for electric fields within oil-pressboard/paper insulation under impulse voltage conditions, which measures the spatial electric field characteristics using Cu-Cu and Al-Al electrodes under various scenarios: with asymmetric and symmetric pressboard coverage and different numbers of insulating paper layers. Findings indicated: (1) In asymmetric pressboard models, Cu-Cu electrodes exhibit a consistent peak electric field of approximately 16 kV/mm, while Al-Al electrodes show peak values of 18.13 kV/mm and -14.98 kV/mm. Charge density patterns are similar, with Cu-Cu at about 68 mu C/m2 and Al-Al at 11.2 mu C/m2 and -124.8 mu C/m2. (2) Symmetric models present consistent peak electric fields and charge densities for both polarities. (3) Increasing insulating paper layers elevates electric field strengths. Both electrodes show the similar peak field of about 17 kV/mm with differing paper layers due to higher charge injection from the Al electrode. (4) Utilizing the Schottky effect and field emission principles, the study clarifies charge generation and migration mechanisms. These insights could provide a theoretical foundation for designing and verifying oil-pressboard/paper insulation structures in transformers.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] PD Detection and Analysis of Oil-pressboard Insulation under Pulsed DC Voltage
    Li, Junhao
    Zhang, Liang
    Han, Xutao
    Yao, Xiu
    Li, Yanming
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 324 - 330
  • [22] Charge behavior in flowing charged oil/pressboard composite insulation system based on electric field measurement
    Wakamatsu, M
    Kato, K
    Koide, H
    Okubo, H
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 189 - 192
  • [23] Time and Space Dependent Characteristics of HVDC Electric Field Stress in Oil-pressboard Composite Insulation Systems
    Nakane, R.
    Kato, K.
    Okubo, H.
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 442 - 445
  • [24] PD Characteristics of Oil-pressboard Insulation under AC and DC Mixed Voltage
    Li, Junhao
    Han, Xutao
    Liu, Zehui
    Yao, Xiu
    Li, Yanming
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 444 - 450
  • [25] Effect of Voltage Waveform Steepness on Partial Discharge and Charge Distribution of Oil-Pressboard Insulation
    Zhu, Ran
    He, Dongxin
    Li, Shuqi
    Wang, Xuliang
    Gu, Yuanli
    Zhai, Yuhui
    Ma, Longfei
    Wang, Liangkai
    Liu, Hongshun
    Li, Qingquan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) : 1224 - 1232
  • [26] Time and space transition characteristics of DC electric field stress in oil-pressboard composite insulation systems
    Nakane, Ryuichi
    Kato, Katsumi
    Hayakawa, Naoki
    Okubo, Hitoshi
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2020, 103 (07) : 13 - 21
  • [27] Exploration on breakdown mechanism of oil-pressboard insulation under polarity reversal voltage
    Wang, Yonghong
    Gao, Ziwei
    Zhu, Xuecheng
    Nie, Hongyan
    Chi, Minghe
    Chen, Qingguo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (21): : 5656 - 5666
  • [28] Study on partial discharge and charge accumulation characteristics of oil-pressboard insulation under DC superimposed harmonic voltage
    Li, Shuqi
    Wang, Qiang
    He, Dongxin
    Wang, Liangkai
    Li, Qingquan
    Si, Wen
    HIGH VOLTAGE, 2023, 8 (06) : 1215 - 1224
  • [29] The Effect of the Non-uniformity in Dielectric Material on Spatial Distributions of Electric Field in a Parallel Plain Electrodes with Oil-pressboard Composite Insulation under DC Voltage
    Gao, Chunjia
    Qi, Bo
    Li, Chengrong
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 306 - 309
  • [30] Effect of Cellulose Impurities on Partial Discharges in Oil-pressboard Insulation under DC Voltage
    Li, Yuan
    Zhang, Qiaogen
    Ding, Yuqin
    Zhao, Yi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2271 - 2273