Performance of microsphere-assisted imaging in bright-field and dark-field microscopy

被引:2
|
作者
Guo, Hongmei [1 ]
Wang, Dong [1 ]
Liu, Yong [1 ]
Jang, Rui [1 ]
Huang, Rong [1 ]
Cao, Yurong [1 ]
Ye, Yong-Hong [1 ]
机构
[1] Nanjing Normal Univ, Sch Comp & Elect Informat, Nanjing 210023, Peoples R China
来源
OPTICS EXPRESS | 2024年 / 32卷 / 22期
基金
中国国家自然科学基金;
关键词
D O I
10.1364/OE.537184
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, we study the imaging performance of microsphere-assisted microscopy (MAM) using microspheres with different refractive indices and immersion conditions under both bright-field illumination (BFI) and dark-field illumination (DFI). The experimental results show that the position of the photonic nanojet of the microsphere plays an important role in MAM imaging. The contrast in imaging is affected by the reflection from the microsphere, the background signal without the microsphere, and the electric field on the substrate surface. In MAM, BaTiO3 glass microspheres achieve better imaging results under BFI when immersed in a polydimethylsiloxane (PDMS) film but are challenging to image under DFI. However, SiO2 and polystyrene microspheres exhibit improved imaging performance under both BFI and DFI with PDMS-covered semi-immersion, and the imaging contrast in DFI is superior to that in BFI under the same conditions. Besides, the Talbot effect is observed by MAM under DFI when imaging 300-nm-diameter hexagonally close-packed nanoparticle arrays. This work reveals the advantage of MAM under DFI in improving the contrast. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:38910 / 38919
页数:10
相关论文
共 50 条
  • [41] Dark-field ghost imaging
    Dou, Ling-Yu
    Cao, De-Zhong
    Gao, Lu
    Song, Xin-Bing
    OPTICS EXPRESS, 2020, 28 (25) : 37167 - 37176
  • [43] DARK-FIELD MICROSCOPY AND PATIENT EDUCATION
    COLE, AM
    NEWCOMB, GM
    NIXON, KC
    AUSTRALIAN DENTAL JOURNAL, 1984, 29 (06) : 394 - 397
  • [44] DARK-FIELD SCANNING OPTICAL MICROSCOPY
    WILSON, T
    HAMILTON, DK
    OPTIK, 1985, 71 (01): : 23 - 26
  • [45] Dark-field optical coherence microscopy
    Villiger, Martin
    Pache, Christophe
    Lasser, Theo
    OPTICS LETTERS, 2010, 35 (20) : 3489 - 3491
  • [46] DARK-FIELD MICROSCOPY OF DENTAL PLAQUE
    NEWMAN, HH
    BRITISH DENTAL JOURNAL, 1985, 159 (09) : 276 - 276
  • [47] Dark-field differential dynamic microscopy
    Bayles, Alexandra V.
    Squires, Todd M.
    Helgeson, Matthew E.
    SOFT MATTER, 2016, 12 (08) : 2440 - 2452
  • [48] SIMULTANEOUS OBSERVATION OF BRIGHT-FIELD AND DARK-FIELD LARGE-ANGLE CONVERGENT-BEAM ELECTRON-DIFFRACTION PATTERNS
    TERAUCHI, M
    TANAKA, M
    JOURNAL OF ELECTRON MICROSCOPY, 1985, 34 (02): : 128 - 135
  • [49] Monte Carlo electron-trajectory simulations in bright-field and dark-field STEM: Implications for tomography of thick biological sections
    Sousa, A. A.
    Hohmann-Marriott, M. F.
    Zhang, G.
    Leapman, R. D.
    ULTRAMICROSCOPY, 2009, 109 (03) : 213 - 221
  • [50] Dark-field optical coherence microscopy
    Pache, C.
    Villiger, M. L.
    Lasser, T.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554