A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS

被引:0
|
作者
Feng, Lanping [1 ]
Wang, Chen [1 ]
Han, Yan [1 ]
Zhang, Wen [1 ]
Guo, Jing-Liang [1 ]
Zhou, Lian [1 ]
Hu, Zhaochu [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
TODGA RESIN COLUMN; RATIO MEASUREMENTS; SEPARATION; ND; CA; FRACTIONATION; LU; HF;
D O I
10.1039/d4ja00332b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in studying zirconium (Zr) stable isotopic fractionation in both low and high-temperature environments has increased significantly in recent years. Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is the preferred technique for stable Zr isotope analysis due to its low sample consumption and high precision. However, the multi-column separation steps required to remove interferences and meet the stringent matrix requirements for Zr isotopes during MC-ICP-MS testing typically make the sample preparation process time-consuming. Here, we present a new, simple, and efficient single-pass chromatographic exchange technique for the chemical isolation of Zr from complex sample matrices. This new separation protocol is based on DGA resin and consists of only three elution steps and two types of acid eluents (15 mL 7 mol L-1 HNO3 and 5 mL 3 mol L-1 HNO3 + 0.1 mol L-1 HF), which afford straightforward separation of Zr with high yield, good purity, and low blank levels. Zr isotope ratios were measured using Neptune Plus MC-ICP-MS with the 91Zr-96Zr double spike in combination with standard-sample bracketing for mass bias correction. The validity of the proposed method is demonstrated by analyzing eight geological reference materials (including BCR-2, which has an extremely high Mo content of similar to 248 mu g g-1) with satisfactory results that are in good agreement with published values. Based on repeated analyses of pure standard solutions and geological reference materials, the long-term measurement reproducibility is better than +/- 0.048 parts per thousand for delta 94Zr. Therefore, the proposed method can be used for the rapid and efficient determination of stable Zr isotope ratios in geological samples.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 50 条
  • [21] Accurate Measurement of Chromium Isotopic Compositions in Geological Reference Materials by Double-Spike MC-ICP-MS
    Shi, Kai
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    ATOMIC SPECTROSCOPY, 2021, 42 (03) : 128 - 133
  • [22] Precise analysis of antimony isotopic composition in geochemical materials by MC-ICP-MS
    Sun, Guangyi
    Wu, Yunjie
    Feng, Xinbin
    Wu, Xian
    Li, Xinyu
    Deng, Qianwen
    Wang, Feiyue
    Fu, Xuewu
    CHEMICAL GEOLOGY, 2021, 582
  • [23] Precise determination of the lithium isotope ratio in geological samples using MC-ICP-MS with cool plasma
    Choi, Min Seok
    Ryu, Jong-Sik
    Park, Ha Yan
    Lee, Kwang-Sik
    Kil, Youngwoo
    Shin, Hyung Seon
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 505 - 509
  • [24] High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
    Tan, Decan
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Lu, Zhuo
    Xu, Wenpo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 713 - 727
  • [25] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [26] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [27] A Rapid and Simple Method for Lithium Purification and Isotopic Analysis of Geological Reference Materials by MC-ICP-MS
    Zhu, Guanhong
    Ma, Jinlong
    Wei, Gangjian
    Zhang, Le
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [28] Effects of different cone combinations on accurate and precise determination of Li isotopic composition by MC-ICP-MS
    Gou, Long-Fei
    Jin, Zhang-Dong
    Deng, Li
    He, Mao-Yong
    Liu, Chun-Yao
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 146 : 1 - 8
  • [29] Determination of the zirconium isotopic composition of the new isotopic standard NRC ZIRC-1 using MC-ICP-MS
    Tian, Shengyu
    Moynier, Frederic
    Inglis, Edward C.
    Jensen, Ninna K.
    Deng, Zhengbin
    Schiller, Martin
    Bizzarro, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (03) : 656 - 662
  • [30] Measurement of the Isotopic Composition of Molybdenum in Geological Samples by MC-ICP-MS using a Novel Chromatographic Extraction Technique
    Li, Jie
    Liang, Xi-Rong
    Zhong, Li-Feng
    Wang, Xuan-Ce
    Ren, Zhong-Yuan
    Sun, Sheng-Ling
    Zhang, Zhao-Feng
    Xu, Ji-Feng
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 345 - 354