A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS

被引:0
|
作者
Feng, Lanping [1 ]
Wang, Chen [1 ]
Han, Yan [1 ]
Zhang, Wen [1 ]
Guo, Jing-Liang [1 ]
Zhou, Lian [1 ]
Hu, Zhaochu [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
TODGA RESIN COLUMN; RATIO MEASUREMENTS; SEPARATION; ND; CA; FRACTIONATION; LU; HF;
D O I
10.1039/d4ja00332b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in studying zirconium (Zr) stable isotopic fractionation in both low and high-temperature environments has increased significantly in recent years. Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is the preferred technique for stable Zr isotope analysis due to its low sample consumption and high precision. However, the multi-column separation steps required to remove interferences and meet the stringent matrix requirements for Zr isotopes during MC-ICP-MS testing typically make the sample preparation process time-consuming. Here, we present a new, simple, and efficient single-pass chromatographic exchange technique for the chemical isolation of Zr from complex sample matrices. This new separation protocol is based on DGA resin and consists of only three elution steps and two types of acid eluents (15 mL 7 mol L-1 HNO3 and 5 mL 3 mol L-1 HNO3 + 0.1 mol L-1 HF), which afford straightforward separation of Zr with high yield, good purity, and low blank levels. Zr isotope ratios were measured using Neptune Plus MC-ICP-MS with the 91Zr-96Zr double spike in combination with standard-sample bracketing for mass bias correction. The validity of the proposed method is demonstrated by analyzing eight geological reference materials (including BCR-2, which has an extremely high Mo content of similar to 248 mu g g-1) with satisfactory results that are in good agreement with published values. Based on repeated analyses of pure standard solutions and geological reference materials, the long-term measurement reproducibility is better than +/- 0.048 parts per thousand for delta 94Zr. Therefore, the proposed method can be used for the rapid and efficient determination of stable Zr isotope ratios in geological samples.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 50 条
  • [1] A simple single-stage extraction method for Mo separation from geological samples for isotopic analysis by MC-ICP-MS
    Feng, Lanping
    Zhou, Lian
    Hu, Wenfeng
    Zhang, Wen
    Li, Baichan
    Liu, Yongsheng
    Hu, Zhaochu
    Yang, Lu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (01) : 145 - 154
  • [2] A single-stage anion exchange separation method for Cd isotopic analysis in geological and environmental samples by MC-ICP-MS
    Zhong, Qiao-Hui
    Yin, Lu
    Li, Jie
    Feng, Yue-Xing
    Shen, Neng-Ping
    Peng, Bing-Yu
    Wang, Zhao-Yang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (11) : 2291 - 2301
  • [4] A rapid and simple single-stage method for Ca separation from geological and biological samples for isotopic analysis by MC-ICP-MS
    Feng Lanping
    Zhou, Lian
    Yang, Lu
    Zhang, Wen
    Wang, Qian
    Tong Shuoyun
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (03) : 413 - 421
  • [5] Determination of the Isotopic Composition of an Enriched Lutetium Spike by MC-ICP-MS
    Lin, Ran
    Zong, Keqing
    Lin, Jie
    Yang, Ao
    Chen, Kang
    Hu, Zhaochu
    Liu, Yongsheng
    ATOMIC SPECTROSCOPY, 2022, 43 (05) : 396 - 402
  • [6] Precise determination of the isotopic composition of Sn using MC-ICP-MS
    Clayton, R
    Andersson, P
    Gale, NH
    Gillis, C
    Whitehouse, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1248 - 1256
  • [7] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [8] A single-step purification method for the precise determination of the antimony isotopic composition of environmental, geological and biological samples by HG-MC-ICP-MS
    Colin, Ferrari
    Eleonore, Resongles
    Remi, Freydier
    Corinne, Casiot
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (04) : 776 - 785
  • [9] Precise and accurate determination of Sm, Nd concentrations and Nd isotopic compositions in geological samples by MC-ICP-MS
    Yang, Yue-Heng
    Chu, Zhu-Yin
    Wu, Fu-Yuan
    Xie, Lie-Wen
    Yang, Jin-Hui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (06) : 1237 - 1244
  • [10] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828