Simulation of hybrid air-cooled and liquid-cooled systems for optimal lithium-ion battery performance and condensation prevention in high-humidity environments

被引:5
|
作者
Zhang, Bixiao [1 ]
Yuan, Nenglin [1 ]
Kong, Benben [2 ]
Zou, Yitao [2 ]
Shi, Hong [1 ]
机构
[1] Jiangsu Univ Sci & Technol, Coll Energy & Power Engn, 2 Mengxi, Zhenjiang 212003, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Key Lab Aircraft Environm Control & Life Support, MIIT, 29 Yudao St, Nanjing 210016, Peoples R China
关键词
Condensation prevention; Battery thermal management; Hybrid cooling system; Computational fluid dynamics (CFD); Entropy weight-TOPSIS method; PHASE-CHANGE MATERIALS; THERMAL MANAGEMENT; PACK; OPTIMIZATION;
D O I
10.1016/j.applthermaleng.2024.124455
中图分类号
O414.1 [热力学];
学科分类号
摘要
As demand for higher discharge rates surges, the trend towards colder liquid cooling in high-humidity environments poses condensation risks in lithium-ion battery thermal management systems, potentially leading to electrical safety hazards. This study introduces an innovative hybrid air-cooled and liquid-cooled system designed to mitigate condensation in lithium-ion battery thermal management systems (BTMS) operating in high-humidity environments. The proposed system features a unique return air structure that enhances the thermal stability and safety of the batteries by recirculating air through the battery box, thereby utilizing residual heat to prevent condensation. Computational Fluid Dynamics (CFD) simulations were employed to analyze and optimize the system's thermal management performance under various airflow velocities and temperature conditions. The study results show that compared to traditional liquid cooling systems, the proposed hybrid system reduces the condensation area by approximately 39.68 % at a wind speed of 0.5 m/s, and the temperature difference decreases by 0.35 K. The integration of flow deflectors further improves the anti-condensation effect, achieving a phase change rate greater than 0 in the cooling area, thereby enabling condensation-free operation throughout the entire cooling zone. A comprehensive evaluation using the entropy weight-TOPSIS method and nonlinear surface fitting was conducted to assess multiple schemes regarding heat dissipation, anti-condensation measures, and energy consumption. The optimal operating conditions were identified as an airflow velocity of 1.29 m/s and a liquid flow velocity of 0.22 m/s, resulting in a maximum temperature difference of 3.98 K, a maximum temperature of 302.36 K, and energy consumption of air cooling and liquid cooling is 0.158 J and 0.192 J. The proposed composite cooling system with a recirculation structure not only addresses the thermal management challenges of lithium-ion batteries but also effectively ensures the insulation safety of electronic components in high-humidity environments.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] A compact and optimized liquid-cooled thermal management system for high power lithium-ion capacitors
    Karimi, Danial
    Behi, Hamidreza
    Hosen, Md Sazzad
    Jaguemont, Joris
    Berecibar, Maitane
    Van Mierlo, Joeri
    APPLIED THERMAL ENGINEERING, 2021, 185
  • [22] Temperature Uniformity Improvement of an Air-Cooled High-Power Lithium-Ion Battery Using Metal and Nonmetal Foams
    Mohammadian, Shahabeddin K.
    Zhang, Yuwen
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (11):
  • [23] Design optimization of forced air-cooled lithium-ion battery module based on multi-vents
    Zhang, Furen
    Wang, Pengwei
    Yi, Mengfei
    JOURNAL OF ENERGY STORAGE, 2021, 40 (40):
  • [24] Analytical methods for determining the effects of lithium-ion cell size in aligned air-cooled battery packs
    Erb, D. C.
    Kumar, S.
    Carlson, E.
    Ehrenberg, I. M.
    Sarma, S. E.
    JOURNAL OF ENERGY STORAGE, 2017, 10 : 39 - 47
  • [25] Maximizing efficiency: exploring the crucial role of ducts in air-cooled lithium-ion battery thermal management
    Gogoi, Bonashree
    Deka, Hiranya
    Sharma, Prabhakar
    Barik, Debabrata
    Medhi, Bhaskar Jyoti
    Bora, Bhaskor Jyoti
    Paramasivam, Prabhu
    Agbulut, Umit
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [26] STUDY ON COOLING OF BIONIC LEAF-VEIN CHANNEL LIQUID-COOLED PLATE FOR LITHIUM-ION BATTERY PACK
    Sun, Guangqiang
    Li, Zhiqiang
    Wang, Fang
    Liu, Xianfei
    Ba, Yichun
    THERMAL SCIENCE, 2024, 28 (5A): : 3907 - 3919
  • [27] Electric-controlled pressure relief valve for enhanced safety in liquid-cooled lithium-ion battery packs
    Song, Yuhang
    Hou, Jidong
    Lyu, Nawei
    Luo, Xinyuan
    Ma, Jingxuan
    Chen, Shuwen
    Wu, Peihao
    Jiang, Xin
    Jin, Yang
    JOURNAL OF ENERGY CHEMISTRY, 2024, 90 : 98 - 109
  • [28] STUDY ON COOLING OF BIONIC LEAF-VEIN CHANNEL LIQUID-COOLED PLATE FOR LITHIUM-ION BATTERY PACK
    SUN, Guangqiang
    LI, Zhiqiang
    WANG, Fang
    LIU, Xianfei
    BA, Yichun
    Thermal Science, 2024, 28 (05): : 3907 - 3919
  • [29] Impact of Aerogel Barrier on Liquid-Cooled Lithium-Ion Battery Thermal Management System's Cooling Efficiency
    Zeng, Keyi
    Zhang, Ying
    Tian, Liyu
    Lai, Zengyan
    Zhu, Liang
    Ma, Chuyuan
    ENERGY TECHNOLOGY, 2024, 12 (11)
  • [30] Electric-controlled pressure relief valve for enhanced safety in liquid-cooled lithium-ion battery packs
    Yuhang Song
    Jidong Hou
    Nawei Lyu
    Xinyuan Luo
    Jingxuan Ma
    Shuwen Chen
    Peihao Wu
    Xin Jiang
    Yang Jin
    Journal of Energy Chemistry, 2024, 90 (03) : 98 - 109