Experimental study on Start-Up and heat transfer characteristics in loop heat pipes with dual heat sources for battery thermal management system

被引:2
|
作者
Hendrayanto, Priska A. [1 ,2 ]
Fathoni, Andhy M. [1 ,3 ]
Aliefiansyah, M. Soultan [1 ]
Putra, Nandy [1 ]
机构
[1] Univ Indonesia, Fac Engn, Dept Mech Engn, Appl Heat Transfer Res Grp, Depok 16424, West Java, Indonesia
[2] Natl Res & Innovat Agcy BRIN, Res Ctr Environm & Clean Technol, Serpong, Banten, Indonesia
[3] Natl Res & Innovat Agcy BRIN, Res Ctr Energy Convers & Conservat, Serpong, Banten, Indonesia
关键词
Electric vehicle; Battery; Loop heat pipe; Thermal management; Start-up characteristics; Heat transfer; PERFORMANCE; WICKS; FOAMS;
D O I
10.1016/j.tsep.2024.102980
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electric vehicles represent a breakthrough in sustainable transportation, significantly diminishing global emissions. The efficacy of lithium-ion batteries is significantly influenced by the operating temperature, with elevated temperatures potentially resulting in thermal runaway. A proficient battery thermal management system (TMS) must resolve this concern and uphold safe temperatures. Loop heat pipes (LHPs) offer passive cooling technology and have garnered the attention of researchers. Nonetheless, research on LHPs for battery thermal management systems is scarce, and prior investigations have concentrated on a singular heat source. A liquid heat pipe with a dual heat source evaporator has been engineered to simulate the battery arrangement of electric vehicles, which typically comprises multiple battery cells. This study seeks to examine the starting and heat transmission characteristics of LHP. Two battery simulators are fabricated from steel blocks equipped with cartridge heaters. A copper evaporator (121 x 56 x 20 mm) is equipped with a stainless-steel screen mesh capillary wick, and thermocouples are linked to a National Instruments data acquisition (NI DAQ) system for the LHP. Ethanol serves as the working fluid at a filling ratio of 60 %. The startup characteristics of the LHP are examined by altering the heat load, coolant flow rate, and coolant temperature. The experimental findings indicate that the LHP effectively initiates operation at heat loads ranging from 20 to 100 W. The LHP with multiple heat sources demonstrates reduced temperatures compared to a single heat source. The best performance of coolant flow rate and temperature for the quickest startup times are 1.5 L/min and 25 degrees C, respectively. The lowest thermal resistance achieved is 0.17 degrees C/W.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] FROZEN START-UP BEHAVIOR OF LOW-TEMPERATURE HEAT PIPES
    FAGHRI, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (07) : 1681 - 1694
  • [42] Effects of evaporator wettability on the start-up and heat transfer performance of an oscillating heat pipe
    Chinchedu, Raghuvaran
    Kupireddi, Kiran Kumar
    Chandramohan, V. P.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (01) : 453 - 463
  • [43] The start-up characteristics of a novel loop heat pipe with stainless steel capillary wick
    Tian, Tao
    Li, Haoyang
    Zhang, Wen
    Lai, Qingzhi
    Xie, Yinmo
    Tan, Jianyu
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [44] Testing and Modeling of the Dynamic Response Characteristics of Pulsating Heat Pipes during the Start-up Process
    Xu Rongji
    Chen Hao
    Wu Qingping
    Xu Shuhui
    Wang Ruixiang
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (01) : 72 - 81
  • [45] Loop Heat Pipes for Thermal Management of Electric Vehicles
    Singh, Randeep
    Nguyen, Tien
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (06)
  • [46] Testing and Modeling of the Dynamic Response Characteristics of Pulsating Heat Pipes during the Start-up Process
    XU Rongji
    CHEN Hao
    WU Qingping
    XU Shuhui
    WANG Ruixiang
    Journal of Thermal Science, 2019, 28 (01) : 72 - 81
  • [47] Testing and Modeling of the Dynamic Response Characteristics of Pulsating Heat Pipes during the Start-up Process
    Rongji Xu
    Hao Chen
    Qingping Wu
    Shuhui Xu
    Ruixiang Wang
    Journal of Thermal Science, 2019, 28 : 72 - 81
  • [48] Experimental study on the influence of surface modification methods of carbon fiber felt on the operation and heat transfer characteristics of loop heat pipes
    Zhang, Yixue
    Liu, Junyu
    Cheng, He
    Luan, Tao
    Yang, Tongqing
    Xue, Hongyao
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [49] Heat transfer in loop heat pipes capillary wick: Effect effective thermal conductivity
    Ren, Chuan
    Wu, Qing-Song
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2007, 21 (01) : 134 - 140
  • [50] Heat transfer modeling of a novel battery thermal management system
    Al-Zareer, Maan
    Dincer, Ibrahim
    Rosen, Marc A.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2018, 73 (05) : 277 - 290