Thermo-hydraulic performance of concentric tube heat exchangers with turbulent flow: Predictive correlations and iterative methods for pumping power and heat transfer

被引:0
|
作者
Ali, Samer [1 ]
Nohra, Chadi [2 ]
Faraj, Jalal [3 ,4 ]
Dbouk, Talib [5 ]
Khaled, Mahmoud [4 ,6 ]
机构
[1] Univ. Lille, Institut Mines-Télécom, Univ. Artois, Junia, ULR 4515 – LGCgE, Laboratoire de Génie Civil et géo-Environnement, Lille,F-59000, France
[2] Beirut Arab University, BAU, Lebanon
[3] Energy and Thermo-Fluid Group, The International University of Beirut BIU, Beirut, Lebanon
[4] Energy and Thermo-Fluid Group, Lebanese International University LIU, Bekaa, Lebanon
[5] CORIA, UMR 6614, CNRS, Normandy Univ., UNIROUEN, Rouen,76000, France
[6] GUST Center for Sustainable Development, Gulf University for Science and Technology, Kuwait
来源
关键词
Air conditioning - Firedamp - Heat pump systems - Heat transfer performance - Newton-Raphson method - Synthesis gas - Turbulence - Turbulent flow;
D O I
10.1016/j.ijft.2024.100898
中图分类号
学科分类号
摘要
This research addresses the problem of predicting the thermo-hydraulic performance of concentric tube heat exchangers (CTHE) under turbulent flow conditions, a critical aspect in energy-efficient industrial systems such as HVAC, power generation, and chemical processing. Existing studies often lack accurate predictive methods for balancing heat transfer performance with pumping power requirements. To tackle this issue, novel correlations and an iterative Newton–Raphson method were developed for predicting pumping power and heat transfer rates. Three-dimensional CFD simulations of a water-to-water counter-flow CTHE were conducted, with Reynolds numbers ranging from 4000 to 8000 for both the hot and cold fluids. The simulations employed the Reynolds-Averaged Navier–Stokes (RANS) equations with the k−ω SST turbulence model. The results demonstrated that increasing the Reynolds number enhances both heat transfer rates and pumping power, with the cold fluid requiring consistently higher pumping power. New correlations were developed to predict pumping power, capturing the impact of both entry and fully developed flow regions. These correlations showed an average error of less than 2.33% when compared with the CFD data. The iterative Newton–Raphson method for predicting heat transfer rates demonstrated high accuracy, with an average error of 0.66% for heat transfer rate, 0.03% for hot fluid outlet temperature, and 0.01% for cold fluid outlet temperature. Additionally, we identified optimal operating conditions for efficient cooling and heating based on the heat capacity ratio (Cr). The novelty of this work lies in the development of new, highly accurate predictive correlations and iterative methods for optimizing CTHE performance, going beyond existing literature by providing comprehensive insights into the relationship between pumping power, heat transfer efficiency, and flow conditions. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [31] Thermo-hydraulic performance of a circular microchannel heat sink using swirl flow and nanofluid
    Ali, Abdullah Masoud
    Rona, Aldo
    Kadhim, Hakim T.
    Angelino, Matteo
    Gao, Shian
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [32] Performance analysis of baffle configuration effect on thermo-hydraulic behavior of shell and tube heat exchanger
    Dineshbabu, C.
    Shivasankaran, N.
    Raja, K. Venkatesh
    Venkatesh, R.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (12) : 6253 - 6264
  • [33] Thermo-hydraulic performance in heat exchanger tube with V-shaped winglet vortex generator
    Promvonge, Pongjet
    Skullong, Sompol
    APPLIED THERMAL ENGINEERING, 2020, 164 (164)
  • [34] Thermo-Hydraulic Performance Analysis on the Effects of Truncated Twisted Tape Inserts in a Tube Heat Exchanger
    Ghalambaz, Mehdi
    Mashayekhi, Ramin
    Arasteh, Hossein
    Ali, Hafiz Muhammad
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    SYMMETRY-BASEL, 2020, 12 (10): : 1 - 22
  • [35] Computational Fluid Dynamics and Optimization of Flow and Heat Transfer in Coiled Tube-in-Tube Heat Exchangers Under Turbulent Flow Conditions
    Aly, Wael I. A.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2014, 6 (03)
  • [36] Deteriorated turbulent heat transfer (DTHT) of gas up-flow in a circular tube: Heat transfer correlations
    Lee, J. I.
    Hejzlar, P.
    Saha, P.
    Kazimi, M. S.
    McEligot, D. M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (21-22) : 5318 - 5326
  • [37] Thermal performance modeling of turbulent flow in multi tube in tube helically coiled heat exchangers
    Fouda, A.
    Nada, S. A.
    Elattar, H. F.
    Refaey, H. A.
    Bin-Mahfouz, Abdullah S.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 135 : 621 - 638
  • [38] State of the art on flow and heat transfer performance of compact fin-and-tube heat exchangers
    A. Y. Adam
    A. N. Oumer
    G. Najafi
    M. Ishak
    M. Firdaus
    T. B. Aklilu
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 2739 - 2768
  • [39] State of the art on flow and heat transfer performance of compact fin-and-tube heat exchangers
    Adam, A. Y.
    Oumer, A. N.
    Najafi, G.
    Ishak, M.
    Firdaus, M.
    Aklilu, T. B.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (04) : 2739 - 2768
  • [40] Thermo-hydraulic performance prediction for offset-strip fin heat exchangers using artificial neural networks
    Kim, Sangmin
    Seo, Young Min
    Yoon, Sang Youl
    Kim, Seokho
    Pandey, Sudhanshu
    Ha, Man Yeong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (05) : 2623 - 2638