Fabrication of tartrazine sensor using zinc oxide/graphitic carbon nitride modified glassy carbon electrode

被引:0
|
作者
Ahmad, Khursheed [1 ]
Khan, Mohd Quasim [2 ]
Khan, Rais Ahmad [3 ]
Dhakad, Iti [4 ]
机构
[1] Yeungnam Univ, Sch Mat Sci & Engn, Gyongsan 38541, South Korea
[2] MJP Rohilkhand Univ, Dept Chem, MMDC Moradabad, Bareilly 244001, UP, India
[3] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11451, Saudi Arabia
[4] Medi Caps Univ, Dept Chem, Indore 453331, Madhya Pradesh, India
关键词
VOLTAMMETRIC DETERMINATION; SUNSET-YELLOW; ELECTROCHEMICAL SENSOR; SYNTHETIC COLORANTS; GRAPHENE; NANOPARTICLES;
D O I
10.1007/s10854-024-13725-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tartrazine (Tz) is well-known synthetic dye and widely used in food industry. Despite its potential applications, Tz has some negative impacts on human beings due to the presence of toxicity and pathogenicity. Thus, it becomes essential to determine and keep an eye on the precise quantification of Tz. Electrochemical method-based sensors have received enormous attention because of their fast processing and response. In this work, we have synthesized ZnO rods under a simple synthesis approach. Graphitic carbon nitride (g-C3N4) was synthesized using melamine precursor whereas the composite of ZnO@g-C3N4 was obtained by a simple room temperature stirring of ZnO and g-C3N4. The as fabricated ZnO, g-C3N4, and composite of ZnO@g-C3N4 were carefully identified by various sophisticated instrumentation techniques viz., powder X-ray diffraction (PXRD), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy. These synthesized g-C3N4, ZnO, and ZnO@g-C3N4 composite have been used for the modification of glassy carbon electrode (GCE) and designated as MGE-2, MGE-3, and MGE-4, respectively, whereas bare GC electrode has been designated as MGE-1. For evaluating the electrochemical sensing performance of the modified electrodes MGE-2, MGE-3, and MGE-4, differential pulse voltammetry (DPV) method has been used. The MGE-4 exhibited the reasonably good detection limit of 0.03 mu M and sensitivity of 1.57 mu A mu M-1 cm-2.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Fabrication of CaTiO3 modified glassy carbon electrode-based hydrogen peroxide sensor
    Ahmad, Khursheed
    Niyitanga, Theophile
    Pathak, Aarti
    Khan, Rais Ahmad
    Khan, Mohd Quasim
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (08) : 2147 - 2157
  • [42] Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode
    WANG Juan~1
    2. Department of Environmental Engineer
    Wuhan University Journal of Natural Sciences, 2005, (05) : 913 - 918
  • [43] Cost Effective Electrochemical Sensor for L-Methionine Based on Graphitic Carbon Nitride Sheets Modified Electrode
    Ajith, Ajay
    John, S. Abraham
    ELECTROANALYSIS, 2023, 35 (02)
  • [44] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [45] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [46] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [47] Voltammetric analysis of As3+and sulfamethoxazole on an electrode modified with a composite of carbon dots and graphitic carbon nitride
    Moundzounga, Theo H. G.
    Peleyeju, Moses G.
    Orimolade, Benjamin O.
    Olatunde, Abimbola M.
    Maboya, Winny K.
    Akpotu, Samson O.
    Chili, Muntuwenkosi M.
    Klink, Michael J.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2025, 20 (03):
  • [48] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547
  • [49] Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode
    Alagarsamy, Periyalagan
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Hong, In-Seok
    Rao, Mettu Mallikarjuna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7930 - 7938
  • [50] Cost-Effective Electrochemical Activation of Graphitic Carbon Nitride on the Glassy Carbon Electrode Surface for Selective Determination of Serotonin
    Kathiresan, Vijayaraj
    Rajarathinam, Thenmozhi
    Lee, Seulah
    Kim, Suhkmann
    Lee, Jaewon
    Thirumalai, Dinakaran
    Chang, Seung-Cheol
    SENSORS, 2020, 20 (21) : 1 - 10