Robust load frequency control in interval power systems via reduced-order generalized active disturbance rejection control

被引:1
|
作者
Safiullah [1 ]
Hote, Yogesh V. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Elect Engn, Roorkee 247667, India
关键词
Active disturbance rejection control; Interval system; Worst-case model identification; Reduced-order modeling; Load frequency control; CONTROL SCHEME; REDUCTION;
D O I
10.1016/j.compeleceng.2024.109788
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Abrupt load changes, structural discrepancies, and parametric uncertainties cause degraded performance of the high-order power systems. This situation creates a problematic endeavor while analyzing the performance of such high-order systems. Hence, a simple and efficient lower-order control methodology can be deployed to sort out the issues related to load frequency control (LFC) in such systems. This study resolves the LFC problem in parametric bounded power systems by developing a worst-case reduced-order generalized active disturbance rejection control (WRGADRC) method. The core concept of the proposed technique entails that a controller will perform well in nominal scenarios if it performs satisfactorily in worst-case conditions. Therefore, an interval system's worst-case reduced-order model is first obtained from its different uncertain models; the reduced order controller is then designed using the GADRC technique. The proposed scheme is rigorously validated on various parametric bounded minimum and non-minimum phase single-area and multi-area power systems, instilling confidence in its ability to achieve minimum frequency deviation in multiple scenarios. The supremacy of the proposed scheme is highlighted over some well-established control techniques in the literature related to the LFC problem.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Design of a robust guidance law via active disturbance rejection control
    Yuan, Yanbo
    Zhang, Ke
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2015, 26 (02) : 353 - 358
  • [42] Design of a robust guidance law via active disturbance rejection control
    Yanbo Yuan
    Ke Zhang
    JournalofSystemsEngineeringandElectronics, 2015, 26 (02) : 353 - 358
  • [43] Active disturbance rejection control based on a cascade estimator composed of reduced-order and full-order extended state observers
    Rojas, Harvey David
    Cortes-Romero, John
    Rojas, Herbert Enrique
    ISA TRANSACTIONS, 2024, 151 : 296 - 311
  • [44] Interval-oriented reduced-order model for uncertain control systems
    Fan, Ziyao
    Yang, Chen
    APPLIED MATHEMATICS AND COMPUTATION, 2025, 495
  • [45] Tracking Control of Chaotic Systems via Optimized Active Disturbance Rejection Control
    Abu Khadra, Fayiz
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [46] Linear active disturbance rejection control approach for load frequency control of two-area interconnected power system
    Huang, Congzhi
    Li, Jing
    Mu, Shicai
    Yan, Huaicheng
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (06) : 1562 - 1570
  • [47] Reduced-order model for robust aeroelastic control
    Brüderlin M.
    Hosters N.
    Behr M.
    CEAS Aeronautical Journal, 2019, 10 (02): : 367 - 384
  • [48] Robust reduced-order control of combustion instabilities
    Haddad, WM
    Leonessa, A
    Corrado, JR
    Kapila, V
    PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 1997, : 253 - 258
  • [49] Reduced-order model based active disturbance rejection control of hydraulic servo system with singular value perturbation theory
    Wang, Chengwen
    Quan, Long
    Zhang, Shijie
    Meng, Hongjun
    Lan, Yuan
    ISA TRANSACTIONS, 2017, 67 : 455 - 465
  • [50] Reduced-order Active Disturbance Rejection Control of DC-Link Voltage of Photovoltaic Grid-connected Inverters
    Zhou, Xuesong
    Liu, Qian
    Ma, Youjie
    Xie, Bingjie
    2021 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2021), 2021, : 565 - 569