Validity of Wearable Gait Analysis System for Measuring Lower-Limb Kinematics during Timed Up and Go Test

被引:0
|
作者
Kataoka, Yoshiaki [1 ,2 ]
Ishida, Tomoya [1 ]
Osuka, Satoshi [1 ]
Takeda, Ryo [3 ]
Tadano, Shigeru [1 ]
Yamada, Satoshi [3 ]
Tohyama, Harukazu [1 ]
机构
[1] Hokkaido Univ, Fac Hlth Sci, Sapporo 0600812, Japan
[2] Hlth Sci Univ, Dept Rehabil, Hokkaido Hosp, Sapporo 0028072, Japan
[3] Hokkaido Univ, Fac Engn, Sapporo 0608628, Japan
关键词
timed up and go test; wearable sensor; kinematics; motion analysis; validation; UP-AND-GO; ACCELERATION; PARAMETERS; STROKE; ADULTS; FALLS;
D O I
10.3390/s24196296
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Few studies have reported on the validity of a sensor-based lower-limb kinematics evaluation during the timed up and go (TUG) test. This study aimed to determine the validity of a wearable gait sensor system for measuring lower-limb kinematics during the TUG test. Ten young healthy participants were enrolled, and lower-limb kinematics during the TUG test were assessed using a wearable gait sensor system and a standard optical motion analysis system. The angular velocities of the hip, knee, and ankle joints in sit-to-stand and turn-to-sit phases were significantly correlated between the two motion analysis systems (R = 0.612-0.937). The peak angles and ranges of motion of hip, knee, and ankle joints in the walking-out and walking-in phases were also correlated in both systems (R = 0.528-0.924). These results indicate that the wearable gait sensor system is useful for evaluating lower-limb kinematics not only during gait, but also during the TUG test.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Validity of AI-Based Gait Analysis for Simultaneous Measurement of Bilateral Lower Limb Kinematics Using a Single Video Camera
    Ino, Takumi
    Samukawa, Mina
    Ishida, Tomoya
    Wada, Naofumi
    Koshino, Yuta
    Kasahara, Satoshi
    Tohyama, Harukazu
    SENSORS, 2023, 23 (24)
  • [42] Target setting for lower limb joint surgery using the Timed Up and Go test in patients with rheumatoid arthritis: A prospective cohort study
    Kojima, Toshihisa
    Ishikawa, Hajime
    Tanaka, Sakae
    Haga, Nobuhiko
    Nishida, Keiichiro
    Yukioka, Masao
    Hashimoto, Jun
    Miyahara, Hisaaki
    Niki, Yasuo
    Kimura, Tomoatsu
    Oda, Hiromi
    Asai, Shuji
    Funahashi, Koji
    Kojima, Masayo
    Ishiguro, Naoki
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2018, 21 (10) : 1801 - 1808
  • [43] Effect of Dual-Task Conditions on Gait Performance during Timed Up and Go Test in Children with Traumatic Brain Injury
    Rahman, Rabiatul Adawiah Abdul
    Rafi, Fazira
    Hanapiah, Fazah Akhtar
    Nikmat, Azlina Wati
    Ismail, Nor Azira
    Manaf, Haidzir
    REHABILITATION RESEARCH AND PRACTICE, 2018, 2018
  • [44] The use of the 6-min walk test as a proxy for the assessment of energy expenditure during gait in individuals with lower-limb amputation
    Kark, Lauren
    McIntosh, Andrew S.
    Simmons, Anne
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (03) : 227 - 234
  • [45] Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model
    Aimad El Habachi
    Florent Moissenet
    Sonia Duprey
    Laurence Cheze
    Raphaël Dumas
    Medical & Biological Engineering & Computing, 2015, 53 : 655 - 667
  • [46] Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model
    El Habachi, Aimad
    Moissenet, Florent
    Duprey, Sonia
    Cheze, Laurence
    Dumas, Raphael
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (07) : 655 - 667
  • [47] Correlation between the Scores of "Timed up and go" Test and Registered Joint Moments of Lower Limb During the Sit-to-Stand Transfer in Elderly with Antecedents of Frequent Falls
    Guzman, R. A.
    Salazar, H. A.
    Cea, A.
    Melian, H. P.
    Cordier, B.
    Silvestre, R. A.
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2011, 29 (02): : 521 - 525
  • [48] Quantifying Steps During a Timed Up and Go Test Using a Wearable Sensor System: A Laboratory-Based Validation Study in Healthy Young and Older Volunteers
    Vavasour, Grainne
    Giggins, Oonagh M.
    Moran, Orla
    Doyle, Julie
    Kelly, Daniel
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6945 - 6948
  • [49] The Timed Up and Go and Two-Minute Walk Test: Exploration of a method for establishing normative values for established lower limb prosthetic users
    Newton, Kate L.
    Evans, Craig
    Osmotherly, Peter G.
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2016, 18 (03) : 161 - 166
  • [50] The effect of a single treatment of the Protonics™ system on lower extremity kinematics during gait and the lateral step up exercise
    McCrory, Jean L.
    Quick, Nancy E.
    Shapiro, Robert
    Ballantyne, Bryon T.
    Davis, Irene
    GAIT & POSTURE, 2007, 25 (04) : 544 - 548