Research on the bond performance between glass fiber reinforced polymer (GFRP) bars and Ultra-high performance concrete(UHPC)

被引:2
|
作者
Xiao, Jie [1 ]
Liu, Lingfei [2 ]
Zeng, Hehui [1 ]
Zhai, Keyi [3 ]
Fu, Jundong [4 ]
Jiang, Haibo [1 ]
Pang, Lei [5 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
[2] Foshan Univ, Sch Transportat Civil Engn & Architecture, Foshan 528225, Peoples R China
[3] Guangxi Pingna Expressway Co Ltd, Nanning 530022, Peoples R China
[4] Southeast Univ, Sch Transportat, Nanjing, Peoples R China
[5] Changan Univ, Sch Civil Engn, Xian 710061, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Ultra-high performance concrete(UHPC); Glass fiber reinforced polymer (GFRP) bar; Pull-out tests; Surface treatment type; Fiber content; BEHAVIOR; STRENGTH; REBARS; UHPC;
D O I
10.1016/j.jobe.2024.111340
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, in order to overcome the problems that steel bars are prone to rust and the ductility of GFRP and ordinary concrete is insufficient, a new type of reinforced concrete structure with good durability and high ductility has been developed by combining glass fiber reinforced polymer (GFRP) bars with ultra-high performance concrete (UHPC). The bond performance between GFRP and UHPC is the guarantee for them to work together and achieve optimal performance, which is worthy of further research. In this paper, pull-out tests were performed on 75 center pull-out samples with a side length of 150 mm, taking into account factors such as GFRP bar diameter, surface treatment type, bond length, and fiber content. The failure modes and bond performance of GFRP bars and UHPC pull-out specimens were investigated. The results indicate that the bond-slip curves of GFRP bars in UHPC and ordinary concrete show similar bond-slip characteristics. Compared with ordinary concrete, UHPC pull-out specimens demonstrate superior mechanical properties, including better bond strength and ductility. The UHPC-GFRP bars and UHPC-steel bars (8 mm and 10 mm) underwent pull-out failure. However, the 12 mm steel bar in UHPC reached its ultimate tensile strength, causing pull-off failure. The bond strength of GFRP bars decreases with the increase of diameter. In addition, with the increase of bond anchorage length, the bond strength decreases. When GFRP bars of the same diameter are anchored in ultra-high-performance concrete, the GFRP bars with ribbed surfaces display superior bond performance compared to those with sandblasted surfaces. Based on the models proposed by previous researchers, this paper proposes a suitable formula for estimating the bond strength between GFRP bars and UHPC. The calculated results are in good agreement with the measured results.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Bond Behavior Between Ultra-High Performance Concrete (UHPC) and Steel Bar with Different Strengths
    Yu, X. M.
    Liu, Z. W.
    Ruan, Y. M.
    Qin, C. C.
    Wang, D. H.
    Ju, Y. Z.
    STRENGTH OF MATERIALS, 2022, 54 (06) : 1138 - 1144
  • [32] Bond performance between BFRP bars and fiber reinforced concrete exposed to high temperature
    Li C.
    Wei F.
    Liu C.
    Zhao J.
    Journal of Railway Science and Engineering, 2023, 20 (08) : 3014 - 3025
  • [33] The bond between glass-fibre-reinforced polymer bars and ultra-high-strength concrete
    Hossain, Khandaker Muhammed Anwar
    Ametrano, David
    Lachemi, Mohamed
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CONSTRUCTION MATERIALS, 2018, 171 (04) : 161 - 176
  • [34] Tension stiffening and cracking of concrete reinforced with glass fiber reinforced polymer (GFRP) bars
    Bischoff, PH
    Paixao, R
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2004, 31 (04) : 579 - 588
  • [35] Bond Performance of GFRP Bars in Glass and Basalt Fiber-Reinforced Geopolymer Concrete Under Hinged Beam Tests
    Erturkmen, Duygu
    Urunveren, Husamettin
    Beycioglu, Ahmet
    Ibadov, Nabi
    Aruntas, Hueseyin Yilmaz
    Garbacz, Andrzej
    MATERIALS, 2025, 18 (03)
  • [36] Bond properties between smooth carbon fibre-reinforced polymer bars and ultra-high performance concrete modified with polymeric latexes and fibres
    Khalil, Nariman
    Assaad, Joseph J.
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2022, 26 (13) : 6211 - 6228
  • [37] Bond strength of GFRP bars to high strength and ultra-high strength fiber reinforced seawater sea-sand concrete (SSC)
    Liao, Jinjing
    Zeng, Jun-Jie
    Bai, Yu-Lei
    Zhang, Lihai
    COMPOSITE STRUCTURES, 2022, 281
  • [38] Bond performance of fiber reinforced polymer bars in normal- and high-strength concrete
    El-Nemr, Amr
    Ahmed, Ehab A.
    Barris, Cristina
    Joyklad, Panuwat
    Hussain, Qudeer
    Benmokrane, Brahim
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 393
  • [39] Experimental study on bond performance of staggered lap rebars in ultra-high performance concrete (UHPC)
    Xie, Yupeng
    Xiong, Ergang
    Gong, Zhongwen
    Zhang, Junce
    Gao, Yuan
    Taciroglu, Ertugrul
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 433
  • [40] Functional microfibre reinforced ultra-high performance concrete (FMF-UHPC)
    Schleiting, Maximilian
    Wetzel, Alexander
    Krooss, Philipp
    Thiemicke, Jenny
    Niendorf, Thomas
    Middendorf, Bernhard
    Fehling, Ekkehard
    CEMENT AND CONCRETE RESEARCH, 2020, 130