High-glide refrigerant blends in high-temperature heat pumps: Part 2-Inline composition determination for binary mixtures

被引:0
|
作者
Brendel, Leon P. M. [1 ]
Bernal, Silvan N. [1 ]
Hemprich, Carl [2 ]
Rowane, Aaron J. [3 ]
Bell, Ian H. [3 ]
Roskosch, Dennis [2 ]
Arpagaus, Cordin [1 ]
Bardow, Andre [2 ]
Bertsch, Stefan S. [1 ]
机构
[1] Eastern Switzerland Univ Appl Sci, Inst Energy Syst, CH-9471 Buchs, Switzerland
[2] Swiss Fed Inst Technol, Energy & Proc Syst Engn, CH-8092 Zurich, Switzerland
[3] Natl Inst Stand & Technol, Appl Chem & Mat Div, Mat Measurement Lab, Boulder, CO 80305 USA
基金
瑞士国家科学基金会;
关键词
High-temperature heat pump; Composition determination; Refrigerants; Blends; Mixtures; Inline; Online; Pompe a` chaleur a` haute tempe<acute accent>rature; De<acute accent>termination de la composition; Frigorige`nes; Me<acute accent>langes; En ligne; TRANS-1-CHLORO-3,3,3-TRIFLUOROPROPENE R1233ZD(E); PRESSURE; EQUATION;
D O I
10.1016/j.ijrefrig.2024.05.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
Refrigerant mixtures are frequently used in air-conditioners and heat pumps. However, mixtures with high glides of 30 K and more during evaporation are rare, partially because there is an increased concern about composition shifts within the system. An easy and reliable inline composition measurement could alleviate these concerns and simplify the handling of systems with high-glide mixtures. This study investigates six composition determination methods, which are all non-invasive, five of which can be conducted during system operation. All methods were applied to all available mixtures in a dataset of 380 data points. The binary and ternary mixtures tested consist of the refrigerants R-1233zd(E), R-1336mzz(Z), R-1234yf, R-1224yd(Z), and R-32. Each method was applied to all datapoints collected with a certain refrigerant mixture at varying operating conditions. The average of the calculated mass fraction was then compared to the manually charged mass fraction. For the density method, this difference of the calculated and measured mass fraction was always less than 0.03 and usually smaller than 0.01 across all tested mixtures. Most other methods performed well with deviations typically less than 0.05. Some of the methods require only low-cost sensors like thermocouples and pressure transducers. Property data of ternary mixtures is also discussed in the study but a composition determination, theoretically possible combining any two of the six methods, is not attempted in this study.
引用
收藏
页码:45 / 57
页数:13
相关论文
共 37 条
  • [21] Study on heat-energy exchange media of Kalina cycle high-pressure and high-temperature vapor-liquid equilibria for the binary mixtures containing perfluorobenzene
    Nakamura, K
    Miyata, T
    Nakamura, K
    Yamada, K
    Katayama, H
    Nagano, Y
    Ohgaki, K
    KAGAKU KOGAKU RONBUNSHU, 2000, 26 (01) : 112 - 115
  • [22] HIGH-TEMPERATURE HEAT CONTENT + FUSION PROPERTIES FOR BINARY CARBONATE MIXTURES - LI2CO3 K2C03 + NA2CO3
    JANZ, GJ
    PERANO, JL
    TRANSACTIONS OF THE FARADAY SOCIETY, 1964, 60 (502P): : 1742 - &
  • [23] High-temperature matrix resins based on bispropargyl ethers (BPEs) - part 2: Curing kinetics of structurally diverse BPEs and their blends with bismaleimide
    Dhanalakshmi, Jeyaraj Pandiyan
    Pitchaimari, Gnanasekar
    Alam, Sarfaraz
    Vijayakumar, Chinnaswamy Thangavel
    HIGH PERFORMANCE POLYMERS, 2014, 26 (07) : 691 - 702
  • [24] Towards development of a prototype high-temperature latent heat storage unit as an element of a RES-based energy system (part 2)
    Karwacki, J.
    Bogucka-Bykuc, K.
    Wlosinski, W.
    Bykuc, S.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2016, 64 (02) : 400 - 408
  • [25] Thermodynamic analysis of cascade high-temperature heat pump using new natural zeotropic refrigerant mixtures: R744/R600 and R744/R601
    Ganesan, P.
    Eikevik, Trygve M.
    Hamid, Khalid
    Wang, Ruzhu
    Yan, Hongzhi
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 154 : 215 - 230
  • [26] HIGH-TEMPERATURE REACTION CALORIMETRY OF SOLID AND LIQUID-PHASES IN PART OF THE QUASI-BINARY SYSTEM CU2S-SB2S3
    BRYNDZIA, LT
    KLEPPA, OJ
    AMERICAN MINERALOGIST, 1988, 73 (7-8) : 707 - 713
  • [27] Influence of composition of magnetic properties and heat capacity of high-temperature superconducting RBa2Cu3O6, 5+δ
    Anshukova, N.V.
    Bugoslavskii, Yu.V.
    Veselago, V.G.
    Golovashkin, A.I.
    Ershov, O.V.
    Zaitsev, I.A.
    Ivanenko, O.M.
    Minakov, A.A.
    Mitsen, K.V.
    Soviet Physics - Lebedev Institute Reports (English Translation of Sbornik ″Kratkie Soobshcheniya po Fizike″. AN SSSR. Fizicheskii Institut im. P.N. Lebedeva), 1988, (10): : 34 - 37
  • [28] DETERMINATION OF THE CHEMICAL-COMPOSITION OF FILMS OF HIGH-TEMPERATURE SUPERCONDUCTORS OF THE TYPE YBA2CU3O7-X (EXCHANGE OF EXPERIENCE)
    KOTELYANSKII, IM
    KRAVCHENKO, VB
    LEBEDEVA, ZM
    LUZANOV, VA
    SOBOLEV, AT
    SHEMET, VV
    INDUSTRIAL LABORATORY, 1990, 56 (05): : 535 - 536
  • [29] Structural Features of Cast Refractory Alloy HP40NbTi High-Temperature Oxidation. Part 2. Microstructure and Phase Composition Evolution
    S. Yu. Kondrat’ev
    S. N. Petrov
    G. P. Anastasiadi
    A. V. Tsemenko
    Metal Science and Heat Treatment, 2020, 62 : 46 - 54
  • [30] Structural Features of Cast Refractory Alloy HP40NbTi High-Temperature Oxidation. Part 2. Microstructure and Phase Composition Evolution
    Kondrat'ev, S. Yu.
    Petrov, S. N.
    Anastasiadi, G. P.
    Tsemenko, A. V.