Heat transfer of mid-deep ground source heat pump for crude oil gathering and transportation

被引:0
|
作者
Yang, Qianru [1 ]
Zhang, Chenghu [1 ]
Jiang, Wenlong [1 ]
Lu, Weijun [1 ]
You, Shijie [2 ]
机构
[1] Harbin Inst Technol, Sch Architecture & Design, Key Lab Cold Reg Urban & Rural Human Settlement En, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Sch Environm, State Key Lab Urban Water Resources & Environm, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Wax precipitation; Crude oil gathering and transportation; Geothermal energy; Mid-deep ground source heat pump; Heat transfer; Numerical models; ABANDONED OIL; EXCHANGER; MODELS; WELLS;
D O I
10.1016/j.icheatmasstransfer.2024.108237
中图分类号
O414.1 [热力学];
学科分类号
摘要
Wax precipitation in crude oil gathering and transportation (COG&T) causes substantial decrease in oil flowability and thus blockages of pipelines, presenting high safety risks and dramatic economic loss. Conventional oil/gas blending and low-temperature transport are inefficient and energy-intensive. Geothermal energy released from abandoned oil wells may be used as renewable heat source, but remains unexplored. This study focused on feasibility of utilizing geothermal energy from abandoned oil wells by mid-deep ground source heat pump (MDGSHP), so as to alleviate wax precipitation for short-distance COG&T. Numerical models of ground heat exchanger (GHE) were established by using finite difference method (FDM) based on validation of engineered examples. The results demonstrated that, to enhance geothermal extraction, it was essential to increase fluid flow rate, lower inlet temperature, use materials with high thermal resistance, and optimize the pipe dimensions. Additionally, the impacts of operational parameters of GHE and COG&T subsystems on MD-GSHP system performances were also analyzed. Increasing inlet temperature by 8 degrees C resulted in 39.5 % reduction in system load and 89.4 % increase in coefficient of performance (COP). This study provides a proof-in-concept demonstration for extracting geothermal energy from abandoned wells by MD-GSHP to mitigate wax precipitation in COG&T project.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ontology of ground source heat pump
    Zhang, Kenan
    Liao, Pin-Chao
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 49 : 51 - 59
  • [22] Heat source performance for solar-ground source heat pump
    Bi, Y
    Chen, L
    Wu, C
    JOURNAL OF THE ENERGY INSTITUTE, 2005, 78 (04) : 185 - 189
  • [23] Influence of heat storage on performance of multi-borehole mid-deep borehole heat exchangers
    Fu, Haiyu
    Yu, Mingzhi
    Liu, Jie
    Cui, Ping
    Zhang, Wenke
    Mao, Yudong
    Zhuang, Zhaoyi
    JOURNAL OF ENERGY STORAGE, 2024, 90
  • [24] DOMESTIC HEAT-PUMP WITH DEEP HOLE GROUND SOURCE EVAPORATOR
    GOULBURN, JR
    FEARON, J
    APPLIED ENERGY, 1983, 14 (02) : 99 - 113
  • [25] Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system
    Pei, Guihong
    Zhang, Liyin
    SPRINGERPLUS, 2016, 5
  • [26] Heat transfer characteristics and Loading Performance of ground-source heat pump system pile
    Zhang, Mengyu
    Zhou, Wanqing
    Gao, Fengqi
    RESEARCH ON MECHANICAL ENGINEERING, CIVIL ENGINEERING AND MATERIAL ENGINEERING, 2014, 454 : 190 - 193
  • [27] Experimental study of heat transfer of buried finned pipe for ground source heat pump applications
    Koyun, Ahmet
    Demir, Hakan
    Torun, Zakir
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (07) : 739 - 743
  • [28] Ground Source Heat Pump with Passive Heat Compensation Tower
    Song Yanli
    Du Tao
    Ren Dong
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 684 - 687
  • [29] Performance study of heat pipe heat exchanger for ground source heat pump
    Hsieh, Jui Ching
    Lin, David T.W.
    Shin, Long Der
    1600, Chinese Mechanical Engineering Society (35): : 165 - 170
  • [30] INFLUENCE FACTORS ANALYSIS ON HEAT TRANSFER PERFORMANCE OF UNDERGROUND HEAT EXCHANGER IN GROUND-SOURCE HEAT PUMP SYSTEM
    Wu, X. Y.
    Dai, X. L.
    Yang, J. C.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 811 - 817