Microdroplet pull-out testing: Significance of fiber fracture results

被引:0
|
作者
Lee, Donghyen [1 ,2 ]
Kim, Jong-Hyun [2 ]
Lee, Seung Jun [3 ]
Kim, Mantae [4 ]
Kwon, Dong-Jun [1 ,2 ]
机构
[1] Gyeongsang Natl Univ, Dept Mat Engn & Convergence Technol, Jinju 52828, South Korea
[2] Gyeongsang Natl Univ, Res Inst Green Energy Convergence Technol, Jinju 52828, South Korea
[3] Korea Natl Univ Transportat, Dept IT Energy Convergence FOUR BK21, Chungju 27469, South Korea
[4] Korea Inst Ceram Engn & Technol, Aerosp Convergence Mat Ctr, Jinju 52851, South Korea
基金
新加坡国家研究基金会;
关键词
Microdroplet pull-out test; Interface; Interfacial shear strength; Matrix; Fiber fractured trendline; INTERFACIAL PROPERTIES; CHEMICAL INTERACTION; CARBON-FIBERS; COMPOSITES; STRENGTH; SURFACES;
D O I
10.1016/j.polymertesting.2024.108631
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fiber reinforced composites are used in structural materials that required light weight and stiffness. The properties of the fibers or matrix are important, but the interfacial properties have a significant impact on the properties of fiber reinforced composite. In this study, the interfacial shear strength (IFSS) was measured using acrylic resin and epoxy resin as base materials. The chemical composition of acrylic and epoxy matrix materials was analyzed to predict the effects on IFSS. Additionally, IFSS was measured through a microdroplet pull-out test. The reliability of the experimental results was enhanced by applying a statistical analysis to IFSS results. In the case of epoxy, GF/epoxy exhibited higher IFSS to twice and half times than CF/epoxy specimens. It means that the surface treatment of the fibers has a significant impact on the interface. In the case of acrylic, IFSS could be measured for GF. But in the case of CF, IFSS was too low to get accurate results of IFSS. Through this research, methods to improve the accuracy of composite interfacial strength measurement experiments were examined, and the study suggested the need for standardized criteria to evaluate composite interfacial adhesion.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Effect of specimen size for fiber pull-out test
    Peng, Xi-Rong
    Yang, Qing-Sheng
    2002, Beijing University of Aeronautics and Astronautics (BUAA) (19):
  • [42] INSTABILITY OF INTERFACIAL DEBONDING DURING FIBER PULL-OUT
    KIM, JK
    BAILLIE, C
    MAI, YW
    SCRIPTA METALLURGICA ET MATERIALIA, 1991, 25 (02): : 315 - 320
  • [43] ON THE ELASTIC FIBER PULL-OUT FROM A FIXED AND FLAT SURFACE - ASYMPTOTIC AND NUMERICAL RESULTS
    PHANTHIEN, N
    PANTELIS, G
    BUSH, MB
    APPLIED MATHEMATICAL MODELLING, 1982, 6 (04) : 257 - 261
  • [44] AN ADVANCED EQUIPMENT FOR SINGLE-FIBER PULL-OUT TEST DESIGNED TO MONITOR THE FRACTURE PROCESS
    HAMPE, A
    KALINKA, G
    MERETZ, S
    SCHULZ, E
    COMPOSITES, 1995, 26 (01): : 40 - 46
  • [45] Advanced interfacial properties of glass fiber/dopamine-epoxy composites using a microdroplet pull-out test and acoustic emission
    Shin, Pyeong-Su
    Kim, Jong-Hyun
    Park, Ha-Seung
    Baek, Yeong-Min
    Kwon, Dong-Jun
    DeVries, K. Lawrence
    Park, Joung-Man
    JOURNAL OF ADHESION, 2021, 97 (05): : 438 - 455
  • [46] PULL-OUT PROGRAMS
    BELLAFIORE, G
    JOURNAL OF LEARNING DISABILITIES, 1990, 23 (09) : 524 - 525
  • [47] Impact pull-out fracture of steel plates jointed by bolt
    Uemura, Yoshiaki
    Aihara, Yasuhiro
    Daimaruya, Masashi
    Fujiki, Hiroyuki
    Kobayashi, Hidetoshi
    Nagai, Katsumi
    Zairyo/Journal of the Society of Materials Science, Japan, 2011, 60 (07) : 662 - 667
  • [48] Fracture mechanics of single-fibre pull-out test
    Wang, C
    JOURNAL OF MATERIALS SCIENCE, 1997, 32 (02) : 483 - 490
  • [49] Monitoring of the fracture mechanisms induced by pull-out and compression in concrete
    Mpalaskas, A. C.
    Vasilakos, I.
    Matikas, T. E.
    Chai, H. K.
    Aggelis, D. G.
    ENGINEERING FRACTURE MECHANICS, 2014, 128 : 219 - 230
  • [50] Fracture mechanics of single-fibre pull-out test
    CHI WANG
    Journal of Materials Science, 1997, 32 : 483 - 490