NIR-Ⅱ fluorescence lateral flow immunosensor based on efficient energy transfer probe for point-of-care testing of tumor biomarkers

被引:0
|
作者
Zhaorui Song [1 ]
Qiulian Hao [1 ]
Bing Li [2 ]
Yuwei Yuan [3 ]
Shanshan Zhang [1 ]
Yongkuan Suo [1 ,4 ,5 ]
HaiHao Han [1 ,4 ,3 ,5 ]
Zhen Cheng [1 ,4 ,2 ,5 ]
机构
[1] Shandong Laboratory of Yantai Drug Discovery,Bohai Rim Advanced Research Institute for Drug Discovery
[2] Institute of Molecular Medicine Joint Laboratory for Molecular Medicine Northeastern University
[3] Pharmacy College,Shandong First Medical University&Shandong Academy of Medical Sciences
[4] State Key Laboratory of Drug Research,Molecular Imaging Center,Shanghai Institute of Materia Medica
[5] University of Chinese Academy of
关键词
D O I
暂无
中图分类号
R730.4 [肿瘤诊断学]; O657.3 [光化学分析法(光谱分析法)]; TP212.3 [生物传感器、医学传感器];
学科分类号
摘要
Fluorescence lateral flow immunoassay(LFA) has emerged as a powerful tool for rapid screening of various biomarkers owing to its simplicity, sensitivity and flexibility. It is noteworthy that fluorescent probe mainly determines the analytical performance of LFA. Due to the emission and excitation wavelengths are located in the visible region, most fluorophores are inevitably subject to light scattering and background autofluorescence. Herein, we reported a novel LFA sensor based on the second near-infrared(NIR-Ⅱ) fluorescent probe with excellent anti-interference capability. The designed NIR-Ⅱ probe was the Nd3+and Yb3+doped rare earth nanoparticles(RENPs) by employing Nd3+as energy donor and Yb3+as energy acceptor, which of the donor-acceptor energy transfer(ET) efficiency reached up to 80.7%. Meanwhile,relying on the convenient and effective encapsulation strategy of poly(lactic-co-glycolic acid)(PLGA) microspheres to RENPs, the surface functionalized NIR-Ⅱ probe(RE@PLGA) was obtained for subsequent bioconjugation. Benefiting from the optical advantages of NIR-Ⅱ probe, this proposed NIR-Ⅱ LFA displayed a good linear relationship ranging from 7 ng/mL to 200 ng/mL for the detection of α-fetoprotein(AFP), an important biomarker of hepatocellular carcinoma(HCC). The limit of detection(LOD) was determined as low as 3.0 ng/m L, which was of 8.3 times lower than clinical cutoff value. It is promising that LFA sensor based on this efficient RENPs probe provides new opportunities for high sensitive detection of various biomarkers in biological samples.
引用
收藏
页码:498 / 502
页数:5
相关论文
共 50 条
  • [21] Flexible Biosensors Based on Colorimetry, Fluorescence, and Electrochemistry for Point-of-Care Testing
    Yan, Tingyi
    Zhang, Guangyao
    Chai, Huining
    Qu, Lijun
    Zhang, Xueji
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [22] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [23] A portable and universal upconversion nanoparticle-based lateral flow assay platform for point-of-care testing
    Gong, Yan
    Zheng, Yamin
    Jin, Birui
    You, Minli
    Wang, Jiayu
    Li, XiuJun
    Lin, Min
    Xu, Feng
    Li, Fei
    TALANTA, 2019, 201 : 126 - 133
  • [24] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    Biosensors and Bioelectronics, 2021, 168
  • [25] DEVELOPMENT AND EVALUATION OF A QUANTITATIVE LATERAL FLOW IMMUNOASSAY FOR THE DETECTION OF FERRITIN AS POINT-OF-CARE TESTING
    Kimura, Fumiaki
    Miyoshi, Sanami
    Mishima, Yasuo
    Shigeto, Nobuyuki
    Fukuda, Tomoko
    Yamahara, Shigehiro
    Matsumura, Tadashi
    Fujii, Shinji
    Tanimoto, Mitsune
    AMERICAN JOURNAL OF HEMATOLOGY, 2013, 88 (05) : E173 - E173
  • [26] Recent advancements in structural improvements of lateral flow assays towards point-of-care testing
    Mahmoudi, Tohid
    de la Guardia, Miguel
    Shirdel, Behnaz
    Mokhtarzadeh, Ahad
    Baradaran, Behzad
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 116 : 13 - 30
  • [27] Ratiometric Fluorescent Lateral Flow Immunoassay for Point-of-Care Testing of Acute Myocardial Infarction
    Wang, Jing
    Jiang, Chenxing
    Jin, Jiening
    Huang, Liang
    Yu, Wenbo
    Su, Bin
    Hu, Jun
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2021, 60 (23) : 13042 - 13049
  • [28] Optical Nanobiosensor-Based Point-of-Care Testing for Cardiovascular Disease Biomarkers
    Vairaperumal, Tharmaraj
    Huang, Chih-Chia
    Liu, Ping-Yen
    ACS APPLIED BIO MATERIALS, 2023, 6 (07) : 2591 - 2613
  • [29] Plasmon-Enhanced Fluorescence Paper Lateral Flow Strip for Point-of-Care Testing of SARS-CoV-2 Antigens
    Hang, Yingjie
    Wang, Anyang
    Tan, Weirui
    Bess, Kimberly
    Eaton, Ashley
    Wu, Nianqiang
    ANALYTICAL CHEMISTRY, 2024, 97 (02) : 1221 - 1228
  • [30] An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers
    Shen, Minjie
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    LAB ON A CHIP, 2020, 20 (15) : 2626 - 2634