Misoperation of high impedance differential protection for main transformer

被引:0
|
作者
Yuan, Cheng [1 ,2 ]
Tai, Nengling [1 ]
机构
[1] Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
[2] Shanghai Electric High Voltage Industry, Shanghai 200063, China
关键词
Electric currents - Transformer protection - Electric power system protection;
D O I
暂无
中图分类号
学科分类号
摘要
The misoperation of the high impedance differential protection for main transformer No.3 in a substation is analyzed based on its principle and main features. Research result shows that, under the nearby large current fault, the differential current induced by the big difference of U-I characteristics between the current transformer of common winding and that of 500 kV or 220 kV presents big value, which will cause the protection misoperation. The counter-measure is to increase the protective settings by adjusting the variable resistors in RADHA differential circuit, which avoids the misoperation caused by the unbalanced currents and voltages generated in RADHA by the through currents during external fault. Field operation shows its effectiveness.
引用
收藏
页码:121 / 123
相关论文
共 50 条
  • [41] Power Transformer Differential Protection Through Gradient of the Differential Current
    de Alencar, Raidson Jenner N.
    Bezerra, Ubiratan Holanda
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2013, 24 (1-2) : 162 - 173
  • [42] Modeling Transformer Differential Protection with Harmonic Restraint
    Lopez, Omar
    Guardado, J. L.
    2015 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2015,
  • [43] The multi-differential relaying for transformer protection
    Li, XH
    Yin, XG
    Chen, DS
    Zhang, Z
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1723 - 1726
  • [44] A new approach for transformer ground differential protection
    Sezi, T
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 394 - 399
  • [45] A wavelet-based differential transformer protection
    Gómez-Morante, M
    Nicoletti, DW
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (04) : 1351 - 1358
  • [46] Transformer differential protection using wavelet transform
    Ozgonenel, Okan
    Karagol, Serap
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 114 : 60 - 67
  • [47] A Countermeasure for the Restraint of the Differential Protection in Converter Transformer
    Wan Danhui
    Chen Yu
    Zheng Junchao
    Wen Minghao
    PROCEEDINGS OF 2018 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, ELECTRONICS AND ELECTRICAL ENGINEERING (AUTEEE), 2018, : 97 - 101
  • [48] Application of transformer ground differential protection relays
    Sutherland, PE
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (01) : 16 - 21
  • [49] Self-adaptive transformer differential protection
    Zhang, Wenkui
    Tan, Qian
    Miao, Shihong
    Zhou, Liangsong
    Liu, Pei
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (01) : 61 - 68
  • [50] Influence of a TCSC in the behaviour of a transformer differential protection
    Arrieta, MAZ
    Argüelles, JFM
    Benito, MS
    Jaurrieta, BL
    Otamendi, PI
    ELECTRIC POWER SYSTEMS RESEARCH, 2005, 74 (01) : 139 - 145