ETAAS determination of palladium in environmental samples with on-line preconcentration and matrix separation

被引:0
|
作者
Limbeck, Andreas [1 ]
Rendl, Josef [1 ]
Puxbaum, Hans [1 ]
机构
[1] Limbeck, Andreas
[2] Rendl, Josef
[3] Puxbaum, Hans
来源
Limbeck, A. (ALimbeck@afm02.iac.tuwien.ac.at) | 1600年 / Royal Society of Chemistry卷 / 18期
关键词
Catalysts - Distillation - Dust - Ethanol - Mass spectrometry - Neutron activation analysis - Particles (particulate matter);
D O I
暂无
中图分类号
学科分类号
摘要
A flow injection procedure with ETAAS detection for the on-line matrix separation and preconcentration of palladium in environmental samples such as airborne particulate matter and road dust was developed. The selective enrichment of palladium was performed on a C18 micro column which has been reversibly loaded with the complexing agent N,N-diethyl-N′-benzoylthiourea. The formed palladium complex was eluted with ethanol and directly introduced into the graphite furnace. With the use of a 1.57 ml sample loop a limit of detection of 23 ng l-1 and a limit of quantification of 39 ng l-1 were obtained for the determination of palladium, with a relative standard deviation being not more than 3.9%. The method including the developed digestion procedure has been evaluated using the certified reference material BCR-723 (road dust). Finally the procedure was applied for the analysis of aerosol samples from the urban site Vienna.
引用
收藏
相关论文
共 50 条
  • [21] Development of an on-line preconcentration system for zinc determination in biological samples
    Dutra, RL
    Maltez, HF
    Carasek, E
    TALANTA, 2006, 69 (02) : 488 - 493
  • [22] An on-line system for preconcentration and determination of lead in wine samples by FAAS
    Lemos, VA
    de la Guardia, M
    Ferreira, SLC
    TALANTA, 2002, 58 (03) : 475 - 480
  • [23] ETAAS determination of palladium in tunnel dust after flow injection separation and preconcentration using a cyclic polyether
    Dimitrova, B
    Benkhedda, K
    Ivanova, E
    Adams, F
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2004, 49 (06): : 346 - 352
  • [24] Flow injection on-line sorption separation and preconcentration with a knotted reactor for electrothermal atomic absorption spectrometric determination of lead in biological and environmental samples
    Yan, XP
    Adams, F
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 459 - 464
  • [25] Graphite furnace atomic absorption spectrometry determination and on-line preconcentration of palladium
    Levai, A
    Lasztity, A
    Zih-Perenyi, K
    Horvath, Z
    MICROCHEMICAL JOURNAL, 1998, 58 (03) : 272 - 280
  • [26] Preconcentration of Arsenic in Water Samples Using the Composition-Induced Phase Separation Method and Determination by ETAAS
    Gucoglu, M.
    Efecinar, M.
    Satiroglu, N.
    PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON HEAVY METALS IN THE ENVIRONMENT, 2013, 1
  • [27] Optimization of flow injection on-line microcolumn preconcentration of ultratrace elements in environmental samples prior to their spectrochemical determination
    Horvath, Z
    Lasztity, A
    ZihPerenyi, K
    Levai, A
    MICROCHEMICAL JOURNAL, 1996, 54 (04) : 391 - 401
  • [28] On-line preconcentration for the ion chromatographic determination of chlorophenolic and phenolic compounds in environmental samples using electrochemical detection
    Kubán, P
    Flowers, H
    ANALYTICA CHIMICA ACTA, 2001, 437 (01) : 115 - 122
  • [29] Application of multi-walled carbon nanotubes as substrate for the on-line preconcentration, speciation and determination of vanadium by ETAAS
    Gil, Raúl A.
    Goyanes, Silvia N.
    Polla, Griselda
    Smichowski, Patricia
    Olsina, Roberto A.
    Martinez, Luis D.
    Journal of Analytical Atomic Spectrometry, 2007, 22 (10): : 1290 - 1295
  • [30] On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry
    Ferrua, N.
    Cerutti, S.
    Salonia, J. A.
    Olsina, R. A.
    Martinez, L. D.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) : 693 - 699