Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis

被引:0
|
作者
El-Said, Emad M. S. [1 ,2 ]
机构
[1] Damietta Univ, Fac Engn, Mech Power Engn Dept, Dumyat 34511, Egypt
[2] Future Higher Inst Engn & Technol, Mansoura, Egypt
关键词
Earth air heat exchanger; Geometric configurations; Thermal-hydraluic analysis; PERFORMANCE; SYSTEM; ENERGY;
D O I
10.1016/j.energy.2024.133766
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pipe layout design has a great effect on the thermal-hydraulic characteristics of earth air heat exchanger (EAHE) systems. So, in the current study proposed four new buried pipe design configurations; low to high to low, high to low to high, spiral, and circular, in addition to the straight or uniform for comparison. These five configurations are tested and analyzed experimentally depending on the thermo-hydraulic performance for summer cooling requirements with variation of Re in the range of 18041-40843. The results show that changing the uniform design of the EAHE with fixed pipe length enhances both the heat transfer process and pressure loss values. At the same operating conditions, the circular design has the best performance compared to the other ones. For all pipe shapes, the cooling effect increases with the increase of air Re. The thermal-hydraulic performance of the circular design pipe is higher than that of the other pipe designs. The highest coefficient of performance (COP) average values that can be obtained at Re = 18041 is 3.05 for circular shape and enhances by 48.08 % compared to uniform shape. The effectiveness of EAHE with circular shape is improved by about 3.52 % compared to uniform shape at Re = 18041. Spiral design is optimum design based on the Nu value which reaches about 48 with enhancement 12.56 % and 0.34 % compared to uniform and circular shapes respectively, at Re = 40843. The hydrothermal performance factor is highest in the case of circular shape with value about 21.9 at Re = 21257. By increasing Re, the drawbacks of the increasing in the total entropy generation are reflected negatively on the exergy efficiency. The specific cost of the circular shape at Re = 40843 is the optimum value by about 0.7 $/W. Spiral and circular shapes have a decrease of CO2 emissions less than uniform shape by percentage varied from 2.93 % to 13.84 % for decrease in the Re from 21257 to 40843. It is concluded that using EAHE with four new shapes is highly efficient in increasing cooling capacity and energy consumption in buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Thermal-hydraulic performance of a plate heat exchanger with grooved copper foam
    Nilpueng, Kitti
    Chomamuang, Tanachon
    Mesgarpour, Mehrdad
    Mahian, Omid
    Wongwises, Somchai
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [32] Thermal-Hydraulic Studies on the Shell-and-Tube Heat Exchanger with Minijets
    Wajs, Jan
    Bajor, Michal
    Mikielewicz, Dariusz
    ENERGIES, 2019, 12 (17)
  • [33] Thermal-hydraulic evaluation of a shell and tube heat exchanger for heating acetone
    Sanchez, A. P.
    Segura Silva, R. M.
    Montalvan Viart, J. R.
    Ranero Gonzalez, E.
    Perez Sanchez, E. J.
    NEXO REVISTA CIENTIFICA, 2021, 34 (04): : 1075 - 1097
  • [34] Parametric and experimental study on thermal performance of an earth-air heat exchanger
    Shukla, Ashish
    Tiwari, G. N.
    Sodha, M. S.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (06) : 365 - 379
  • [35] Thermal Performance of Earth–Air Heat Exchanger Using an Experimental Test Rig
    Saif Nawaz Ahmad
    Om Prakash
    Arabian Journal for Science and Engineering, 2023, 48 : 11665 - 11678
  • [36] Thermal Hydraulic Performance and Characteristics of a Microchannel Heat Exchanger: Experimental and Numerical Investigations
    Pandey, Vishwas Kumar
    Choudhary, Vishwjeet
    Ranganayakulu, Chennu
    Aneesh, A. M.
    ASME JOURNAL OF HEAT AND MASS TRANSFER, 2025, 147 (02):
  • [37] Thermal modeling of a greenhouse with an integrated earth to air heat exchanger: an experimental validation
    Ghosal, MK
    Tiwari, GN
    Srivastava, NSL
    ENERGY AND BUILDINGS, 2004, 36 (03) : 219 - 227
  • [38] THERMAL-HYDRAULIC CHARACTERISTICS OF A HEAT-EXCHANGER - THE VERTICAL RECTANGULAR FINS BEING ALIGNED PARALLEL TO THE MEAN AIR-FLOW IN THE DUCT
    NAIK, S
    PROBERT, SD
    WOOD, CI
    APPLIED ENERGY, 1988, 29 (03) : 217 - 252
  • [39] Experimental study on the thermal-hydraulic performance of modified chevron plate heat exchanger by electrochemical etching method
    Nguyen, Dong Ho
    Kim, Koung Moon
    Shim, Gyu Hyeon
    Kim, Ji Hoon
    Lee, Chang Hun
    Lim, Sun Taek
    Ahn, Ho Seon
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 155
  • [40] Experimental study on thermal-hydraulic performance of a wavy fin-and-flat tube aluminum heat exchanger
    Dong, Junqi
    Su, Lin
    Chen, Qian
    Xu, Weiwu
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 32 - 39