An analysis on the velocity of dust particles in the plate-type electrostatic precipitators used in thermoelectric power plants

被引:0
|
作者
机构
[1] Popa, Gabriel Nicolae
[2] Şora, Ioan
[3] Diniş, Corina Maria
[4] Deaconu, Sorin Ioan
来源
Popa, Gabriel Nicolae (gabriel.popa@fih.upt.ro) | 1600年 / Wroclaw University of Science and Technology卷 / 40期
关键词
Collection efficiency - Dust particle - Gas velocity - Input and outputs - Input channels - Migration velocity - Output channels - Particle velocity distributions - Plate-Type - Traveling time;
D O I
10.37190/epe140107
中图分类号
学科分类号
摘要
Experimental data collected from different plate-type electrostatic precipitators used in a thermoelectric power plant has been analyzed. The following parameters were considered: the collection efficiency, average migration velocity of dust particles, velocity distribution of the gas in the input and output channels of precipitators. The average migration velocity of dust particles can be estimated using various mathematical models, and the gas velocity can be computed using the velocity distributions from the input channels of the precipitators. The traveling time of dust particles between the electrodes is smaller than the traveling time along the precipitator sections. © 2014, Technical University of Wroclaw. All rights reserved.
引用
收藏
相关论文
共 36 条
  • [11] Analysis of some solutions that improve performances of plate-type electrostatic precipitators
    Department of Electrical Engineering and Industrial Informatics, Politechnica University Timişoara, Str. Revoluţiei, no.5, Hunedoara, Romania
    不详
    不详
    WSEAS Trans. Circuits Syst., 2008, 8 (843-854):
  • [12] Electrostatic precipitators used in the ecological conversion of power in coal-fired thermoelectric power plants
    Artino, Alexandru
    Cardu, Mircea
    Energy Conversion and Management, 1994, 35 (06): : 477 - 481
  • [13] Analysis of mathematical models of current-voltage characteristics for plate-type electrostatic precipitators
    Popa, Gabriel Nicolae
    Sora, Ioan
    Vaida, Victor
    Popa, Iosif
    Deaconu, Sorin
    PROCEEDINGS OF THE 9TH WSEAS INTERNATIONAL CONFERENCE ON AUTOMATION AND INFORMATION, 2008, : 288 - +
  • [14] ELECTROSTATIC PRECIPITATORS USED IN THE ECOLOGICAL CONVERSION OF POWER IN COAL-FIRED THERMOELECTRIC-POWER PLANTS
    ARTINO, A
    CARDU, M
    ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (06) : 477 - 481
  • [15] A CONTRIBUTION TO THE MODELING OF DUST SEPARATION IN A PLATE-TYPE ELECTROSTATIC PRECIPITATOR
    PETROLL, J
    STAUB REINHALTUNG DER LUFT, 1987, 47 (1-2): : 1 - 3
  • [16] Simulations and Measurements of Some Parameters from Plate-Type Electrostatic Precipitators with Three Sections
    Popa, Gabriel Nicolae
    Vaida, Victor
    Iagar, Angela
    Dinis, Corina Maria
    PROCEEDINGS OF THE 2ND WSEAS/IASME INTERNATIONAL CONFERENCE ON ENERGY PLANNING, ENERGY SAVING, ENVIRONMENTAL EDUCATION, 2008, : 106 - 112
  • [17] Numerical Simulations of the Electric Parameters of the Plate-Type Electrostatic Precipitators Supplied with DC Voltage
    Popa, Gabriel Nicolae
    Dinis, Corina Maria
    Deaconu, Sorin Ioan
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2016), 2016, : 75 - 78
  • [18] The effect of oxidation temperature on the thermoelectric performance of a plate-type thermoelectric power generator
    Ogi, Naoto
    Tohmyoh, Hironori
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58 (SD)
  • [19] Numerical analysis of the electric field in plate-type electrostatic separators
    Vlad, S
    Mihailescu, M
    Rafiroiu, D
    Iuga, A
    Dascalescu, L
    CONFERENCE RECORD OF THE 1998 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3, 1998, : 1961 - 1966
  • [20] Numerical analysis of the electric field in plate-type electrostatic separators
    Vlad, S
    Mihailescu, M
    Rafiroiu, D
    Iuga, A
    Dascalescu, L
    JOURNAL OF ELECTROSTATICS, 2000, 48 (3-4) : 217 - 229