Optimization design and shaking table test of tuned mass damper for enhancing seismic performance in thermal power plants

被引:0
|
作者
Shi, Luwei [1 ]
Peng, Lingyun [1 ]
Zhang, Ruhan [1 ]
Kang, Yingjie [2 ]
Guan, Yaxi [1 ]
Li, Wenzhi [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[2] Shijiazhuang Tiedao Univ, Key Lab Rd & Railway Engn Safety Control, Minist Educ, Shijiazhuang 050043, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal power plant; Tuned mass damper; Optimized design; Equivalence model; Adjustable damping; Shaking table test; VIBRATION CONTROL;
D O I
10.1016/j.istruc.2024.107405
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to improve the seismic performance of traditional thermal power plant structures. Taking a certain thermal power plant as the research object, a simplified three-floor equivalent model was designed, aiming to achieve similar fundamental periods and considering the floor height and mass distribution. A coal bunker was used as the mass unit in the tuned mass damper (TMD) design. The optimal TMD design parameters for the two orthogonal directions of the structure were determined using the steady-state complex modal decomposition method and fixed-point theory. Moreover, a velocity-dependent and adjustable damping electromagnetic damping device were designed as the damping unit in the TMD. Shaking table tests were conducted in two orthogonal directions to investigate the control effects in the interstory drift angle, floor acceleration, and top-floor displacement response, thus verifying the effectiveness and feasibility of the TMD scheme. The effectiveness of the vibration control under the abovementioned optimal TMD design scheme was further validated through finite element simulations of the original thermal power plant structure. This study demonstrates that due to the process requirements of thermal power plant structures, the coal hunker has a massive weight and is positioned at a high location. Based on this characteristic, directly using coal bunkers as mass units for the TMD with the optimal parameter design can significantly reduce the various seismic responses, achieving a 25 % to 45 % seismic reduction rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Stochastic design of multiple tuned mass damper system under seismic excitation
    Kamalesh Bhowmik
    Nirmalendu Debnath
    Archive of Applied Mechanics, 2022, 92 : 383 - 404
  • [42] Optimal design of friction tuned mass damper for seismic control of an integral bridge
    Labbafi, S. Fatemeh
    Shooshtari, Ahmad
    Mohtashami, Ehsan
    STRUCTURES, 2023, 58
  • [43] Seismic performance of tuned mass damper on Shazand Railway Bridge induced by train
    Latifi, R.
    Razani, R.
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2015, 3 (03) : 55 - 62
  • [44] Tuned viscous mass damper (TVMD) coupled wall system for enhancing seismic performance of high-rise buildings
    Ji, Xiaodong
    Zhang, Junshan
    Ikago, Kohju
    Chakraborty, Sanjukta
    Kanno, Hideto
    ENGINEERING STRUCTURES, 2021, 240
  • [45] Performance of a gas-spring tuned mass damper under seismic excitation
    Rong, Kunjie
    Lu, Zheng
    STRUCTURAL ENGINEERING AND MECHANICS, 2021, 80 (02) : 157 - 168
  • [46] Vibration Control Performance Analysis and Shake-Table Test of a Pounding Tuned Rotary Mass Damper under the Earthquake
    Li, Shujin
    Sun, Lei
    Kong, Fan
    SHOCK AND VIBRATION, 2019, 2019
  • [47] Shaking table test study on seismic performance of RC frame structure with NES
    Yang, Haixu
    Li, Zhuo
    Wang, Haibiao
    Zhang, Maohua
    Ni, Songyuan
    STRUCTURES, 2023, 47 : 153 - 164
  • [48] Optimization of mix design of micro-concrete for shaking table test
    Zhou, Ji
    Gao, Xin
    Liu, Chaofeng
    ADVANCES IN CONCRETE CONSTRUCTION, 2022, 13 (03) : 215 - 221
  • [49] Shaking Table Test on Seismic Performance of Combined High Voltage Circuit Breaker
    Li Hongbo
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING (ICAESEE 2019), 2020, 446
  • [50] Shaking Table Test Investigation on Seismic Performance of Joint Model of Immersed Tunnel
    Zhang, Xueming
    Song, Linlin
    Chen, Hongjuan
    Chen, Shicai
    Hu, Zhinan
    Li, Yong
    SHOCK AND VIBRATION, 2022, 2022