Microchannel plate gated X-ray nanosecond framing camera

被引:0
|
作者
Niu, Lihong [1 ]
Liu, Jinyuan [1 ]
Peng, Wenda [1 ]
Niu, Hanben [1 ]
Yang, Qinlao [1 ]
Liao, Hua [1 ]
Zhou, Junlan [1 ]
Zhang, Jinsong [1 ]
机构
[1] Institute of Optoelectronics, Shenzhen University, Shenzhen 518060, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2008年 / 28卷 / 07期
关键词
Light emission - Phosphors - Pinch effect - CCD cameras - Microchannels - Pinhole cameras - Image storage tubes;
D O I
10.3788/AOS20082807.1274
中图分类号
学科分类号
摘要
A novel microchannel plate (MCP) gated X-ray nanosecond framing camera is developed. The camera system consists of a proximity-focused framing image-converted tube with traveling-wave gated micro-stripe optoelectric cathode, an electronic control unit, a mechanical system for pinholes mounting, adjusting and a high vacuum system. The electronic control unit provides all the power supply of the camera system including voltage to phosphor screen, gating pulses to MCP, bias and static checking voltage of MCP. The images are recorded with a scientific CCD camera coupled to the fiber optic phosphor screen. The photocathode of image-converted tube consists of Au of 50 nm thickness. Eight framing images can be abstained. The energy spectrum response of the camera ranges from 0.1 keV to 10 keV. The exposure time of the camera can be changed is 1 ns, 2 ns and 5 ns in three scales and time interval between frames from 2 ns, 5 ns and 10 ns in three scales. The dynamic spatial resolution is better than 18 lp/mm. The triggering jitter is down to 100 ps with exposure time shifting less than 5%. The fiber remote transmission and control are incorporated in the nanosecond framing camera system. The achieval experimental results on the static, dynamic characteristics and Z-pinch application show that the camera can run in a strong electromagnetic environment. In this case, the camera has little geometric distortion and wide dynamic range and provides good control and high capturing rate. Such a camera system can be utilized in the investigation of Z-pinch for recording X-ray.
引用
收藏
页码:1274 / 1278
相关论文
共 50 条
  • [31] Angular sensitivity of gated microchannel plate framing cameras
    Landen, OL
    Lobban, A
    Tutt, T
    Bell, PM
    Costa, R
    Hargrove, DR
    Ze, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 709 - 712
  • [32] GATED X-RAY IMAGER GAIN CORRECTION USING A TAPERED MICROCHANNEL-PLATE STRIPLINE
    WATT, RG
    OERTEL, J
    ARCHELUTA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (08): : 2585 - 2586
  • [33] Microchannel plate X-ray optics on the Mercury Imaging X-ray Spectrometer
    Martindale, Adrian
    Pearson, James F.
    Feldman, Charly H.
    Butcher, Gillian I.
    Willingale, Richard
    Fairbend, Ray
    Schyns, Emile
    Bunce, Emma J.
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [34] Monte Carlo simulation for microchannel plate framing camera
    Cai, Houzhi
    Liu, Jinyuan
    Niu, Lihong
    Peng, Wenda
    Zhou, Junlan
    Gu, Li
    Niu, Hanben
    Long, Jinghua
    OPTICAL ENGINEERING, 2010, 49 (08)
  • [35] PICOSECOND FRAMING CAMERA USING A PASSIVE MICROCHANNEL PLATE
    LIEBER, AJ
    SUTPHIN, HD
    APPLIED OPTICS, 1979, 18 (06): : 745 - 746
  • [36] Application of an x-ray framing camera in ICF diagnostic
    Wen, SH
    Cheng, JX
    Yang, CB
    Wen, TS
    Tang, DY
    Zheng, ZJ
    Chao, LF
    Chen, HS
    ECLIM 2000: 26TH EUROPEAN CONFERENCE ON LASER INTERACTION WITH MATTER, 2001, 4424 : 187 - 189
  • [37] X-RAY FRAMING CAMERA FOR DENSE-PLASMAS
    SCHNEIDER, R
    GILMAN, C
    GENUARIO, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 880 - 880
  • [38] Numerical Model Calculation of X-ray Framing Camera
    Koga, M.
    Shiraga, H.
    SELECTED PAPERS FROM THE 31ST INTERNATIONAL CONGRESS ON HIGH-SPEED IMAGING AND PHOTONICS, 2017, 10328
  • [39] X-RAY FRAMING CAMERA IMAGES OF IMPLODING TARGETS
    KATAYAMA, M
    TANAKA, KA
    YAMANAKA, T
    IZAWA, Y
    NAKAI, S
    NAKAI, M
    YAMANAKA, C
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 406 - 410
  • [40] A MICROCHANNEL PLATE INTENSIFIED, SUBNANOSECOND, X-RAY-IMAGING CAMERA
    CARTER, MR
    MCKINLEY, BJ
    TIRSELL, KG
    PHYSICA SCRIPTA, 1990, 41 (04) : 390 - 395