Review on the characteristic of new cellulose insulation paper used in the converter transformer

被引:0
|
作者
Liao, Ruijin [1 ]
Wang, Jiyu [1 ]
Yuan, Yuan [1 ]
Gao, Fei [2 ]
Li, Jian [1 ]
机构
[1] State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing,400044, China
[2] China Electric Power Research Institute, Beijing,100192, China
关键词
Outages - Winding - Cellulose - Thermal aging - Thermal insulation - Rectifying circuits - Fault detection - Oil filled transformers;
D O I
暂无
中图分类号
学科分类号
摘要
Converter transformer is one of the most critical and strategic components in HVDC transmission, and its insulation system of the valve-side winding generally has high failure rate because of complex operation conditions. Although the traditional methods can improve the equipment reliability through on-line monitoring and fault diagnosis techniques, yet it is hard to guarantee the efficiency and economy when the maintenance cost and power transmission loss cost during the outages are taken into account. As the major insulation system in the valve-side winding, oil-paper insulation plays a vital role in the reliability and safety of converter transformer. Wherein, the insulation paper of the insulation system is not only deteriorated by the long-term impact of thermal stress, but also subjected to complex operating conditions such as AC-DC hybrid voltage and polarity reversal. Besides, the insulation paper is considered to be irreversible after degradation. Therefore, it is essential to improve the performance of insulation paper. This paper overviews the overseas and domestic research status combined with the studies of our group, aiming at improving the anti-thermal aging performance, breakdown performance and space charge characteristics of cellulose insulation paper. All the mentioned methods will be analyzed in this paper, and a new cellulose insulation paper used in the converter transformer is investigated. © 2016, The editorial office of Transaction of China Electrotechnical Society. All right reserved.
引用
收藏
页码:1 / 15
相关论文
共 50 条
  • [21] Study on Characteristic Parameters of a New Converter Transformer for HVDC Systems
    Li, Yong
    Luo, Longfu
    Rehtanz, Christian
    Nakamura, Kazuo
    Xu, Jiazhu
    Liu, Fusheng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 2125 - 2131
  • [22] A STUDY OF DEGRADATION OF CELLULOSIC INSULATION MATERIALS IN A POWER TRANSFORMER .2. TENSILE-STRENGTH OF CELLULOSE INSULATION PAPER
    HILL, DJT
    LE, TT
    DARVENIZA, M
    SAHA, T
    POLYMER DEGRADATION AND STABILITY, 1995, 49 (03) : 429 - 435
  • [23] Study of the degradation of cellulosic insulation materials in a power transformer. Part III: degradation products of cellulose insulation paper
    Univ of Queensland, Brisbane
    Polym Degradation Stab, 2 (211-218):
  • [24] Investigation on Heating Aging Mechanism of Cellulose Paper for Oil-Immersed Transformer Main Insulation
    Liu, Daosheng
    Deng, Christopher Garang
    Xu, Xiangdong
    Jing, Ye
    Li, Xiaofan
    Noubissi, Romaric Kammeugue
    Li, Xiaolong
    2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
  • [25] Effect of melamine modified cellulose nanocrystals on the performance of oil-immersed transformer insulation paper
    Chen, QiJie
    Kang, MeiCun
    Xie, QiongHua
    Wang, JianHui
    CELLULOSE, 2020, 27 (13) : 7621 - 7636
  • [26] Effect of melamine modified cellulose nanocrystals on the performance of oil-immersed transformer insulation paper
    QiJie Chen
    MeiCun Kang
    QiongHua Xie
    JianHui Wang
    Cellulose, 2020, 27 : 7621 - 7636
  • [27] THERMAL AGING OF CELLULOSE PAPER INSULATION
    LAWSON, WG
    SIMMONS, MA
    GALE, PS
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1977, 12 (01): : 61 - 66
  • [28] Major Insulation Design Consideration of Converter Transformer
    Shuai Yuanming
    Han Xiaodong
    Zhang Liangxian
    Yang Chun
    Hu Xiaobo
    Wu Hao
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 1004 - 1007
  • [29] The effect of moisture and temperature on the oil-immersed-paper used in EHV converter transformer
    Wu, Hao
    Liu, Lilan
    Liu, Teqing
    Peng, Zongren
    Lv, Xiaolu
    Liao, Jintao
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 577 - 580
  • [30] A STUDY OF DEGRADATION OF CELLULOSIC INSULATION MATERIALS IN A POWER TRANSFORMER .1. MOLECULAR-WEIGHT STUDY OF CELLULOSE INSULATION PAPER
    HILL, DJT
    LE, TT
    DARVENIZA, M
    SAHA, T
    POLYMER DEGRADATION AND STABILITY, 1995, 48 (01) : 79 - 87