Comparison of soft X-ray spectro-ptychography and scanning transmission X-ray microscopy

被引:0
|
作者
Hitchcock, Adam P. [1 ]
Zhang, Chunyang [1 ,2 ]
Eraky, Haytham [1 ]
Higgins, Drew [2 ]
Belkhou, Rachid [3 ]
Millle, Nicolas [3 ]
Swaraj, Sufal [3 ]
Stanescu, Stefan [3 ]
Sun, Tianxiao [4 ,5 ]
Wang, Jian [4 ]
机构
[1] McMaster Univ, Chem & Chem Biol, Hamilton, ON L8S4M1, Canada
[2] McMaster Univ, Chem Engn, Hamilton, ON L8S4M, Canada
[3] LOrme Merisiers, Synchrotron SOLEIL, partementale 128, F-91190 St aubin, France
[4] Canadian Light Source, 44 Innovat Blvd, Saskatoon, SK S7N 2V3, Canada
[5] Univ Texas Austin, Walker Dept Mech Engn, Austin, TX 78712 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Spectro-ptychography; Cu nanoparticles; Cu 2p X-ray absorption; Scanning transmission X-ray microscopy; STXM; IN-SITU; RESOLUTION; SPECTROMICROSCOPY; ELECTRON; RECONSTRUCTION; BEAMLINE; CARBON;
D O I
10.1016/j.elspec.2024.147487
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Over the past decade advances in instrumentation and software have enabled development of spectro-ptychography (SP) as a higher spatial resolution extension of scanning transmission X-ray microscopy (STXM). Direct comparisons are made of same-area chemical state imaging of Cu nanoparticles using STXM and SP in order to compare and contrast the two approaches. We show that SP gives very similar chemical state information as STXM with significantly better spatial resolution and much higher quality images and chemical maps, on account of finer pixels in the reconstructed images. When defocused spot sizes are used (i.e., 1-3 mu m, as opposed to full-focus 30-50 nm) SP data acquisition is faster and the radiation dose delivered to the sample is smaller than the corresponding STXM measurement. The limitations of SP are primarily related to the time and complexity of the ptychographic reconstruction. We argue that these documented advantages mean that SP rather than STXM should be used for more complex studies such as tomography and in situ studies, especially when radiation damage is a concern. The main point of this manuscript is to illustrate, with scientifically relevant samples, the significant advantages of SP relative to conventional STXM, with the goal of encouraging greater use of SP.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A bidirectional scanning method for scanning transmission X-ray microscopy
    Sun, Tianxiao
    Zhang, Xiangzhi
    Xu, Zijian
    Wang, Yong
    Guo, Zhi
    Wang, Jian
    Tai, Renzhong
    Journal of Synchrotron Radiation, 2021, 28 : 512 - 517
  • [32] Analysis of Cr(VI) Bioremediation by Citrobacter freundii Using Synchrotron Soft X-ray Scanning Transmission X-ray Microscopy
    Anil, Amith G.
    Swaraj, Sufal
    Subramanian, Sankaran
    Ramamurthy, Praveen C.
    QUANTUM BEAM SCIENCE, 2021, 5 (04)
  • [33] Scanning transmission X-ray microscopy with a segmented detector
    Feser, M
    Jacobsen, C
    Rehak, P
    DeGeronimo, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 529 - 534
  • [34] Scanning transmission x-ray microscopy with a configurable detector
    Gianoncelli, A.
    Morrison, G. R.
    Kaulich, B.
    Bacescu, D.
    Kovac, J.
    APPLIED PHYSICS LETTERS, 2006, 89 (25)
  • [35] Contrast mechanisms in scanning transmission x-ray microscopy
    Thibault, Pierre
    Dierolf, Martin
    Kewish, Cameron M.
    Menzel, Andreas
    Bunk, Oliver
    Pfeiffer, Franz
    PHYSICAL REVIEW A, 2009, 80 (04):
  • [36] The scanning X-ray microprobe at the ESRF "x-ray microscopy" beamline
    Susini, J
    Salomé, M
    Fayard, B
    Ortega, R
    Kaulich, B
    SURFACE REVIEW AND LETTERS, 2002, 9 (01) : 203 - 211
  • [37] HESSIAN SPLINES FOR SCANNING TRANSMISSION X-RAY MICROSCOPY
    Debarre, Thomas
    Watts, Benjamin
    Roesner, Benedikt
    Unser, Michael
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 199 - 202
  • [38] Quantitative analysis of mammalian chromosome by scanning transmission soft X-ray microscopy
    Shinohara, K.
    Ohigashi, T.
    Tone, S.
    Kado, M.
    Ito, A.
    ULTRAMICROSCOPY, 2018, 194 : 1 - 6
  • [39] Quantitative study of mammalian cells by scanning transmission soft X-ray microscopy
    Shinohara, K.
    Ohigashi, T.
    Tone, S.
    Kado, M.
    Ito, A.
    X-RAY MICROSCOPY CONFERENCE 2016 (XRM 2016), 2017, 849
  • [40] HERMES: a soft X-ray beamline dedicated to X-ray microscopy
    Belkhou, Rachid
    Stanescu, Stefan
    Swaraj, Sufal
    Besson, Adrien
    Ledoux, Milena
    Hajlaoui, Mahdi
    Dalle, Didier
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 968 - 979