Odor biosensor system based on image lock-in measurement for odorant discrimination

被引:0
|
作者
Sukekawa Y. [1 ]
Nakamoto T. [1 ]
机构
[1] Laboratory for Future Interdisciplinary Research of Science and Technology (FIRST), Institute of Innovative Research (IIR), Tokyo Institute of Technology, R2-5, 4259, Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa
基金
日本学术振兴会;
关键词
FPGA; Image processing; Lock-in measurement; Odor sensor; Principal component analysis;
D O I
10.1541/ieejsmas.138.477
中图分类号
学科分类号
摘要
There has been so far few odor sensors with an array of the biosensor elements. However, an odor sensor constructed in this fashion is expected to have high performance in terms of the ability to discriminate between odorants. In this study, a parallel lock-in measurement circuit was developed to acquire the fluorescent image of the cells even under an ambient light. Since that circuit can extract only the responses of the cells from the fluorescent image, its output represents a specific pattern corresponding to the odorant. Therefore, principal component analysis was applied to that output in order to confirm the availability of the odorant discrimination by using a fluorescent image. It was found that the output pattern from the developed circuit included information enough to discriminate between at least two types of odorants. © 2018 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:477 / 484
页数:7
相关论文
共 50 条
  • [21] Electrochemical Impedance Spectroscopy Measurement of Lithium Battery Based on Lock-in amplifier
    Xu, Guanghao
    Duan, Ran
    Dong, Ming
    Ren, Ming
    Xie, Jiacheng
    Hu, Yizhuo
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 678 - 681
  • [22] Measurement on carbon lock-in of China based on RAGA-PP model
    Niu, Honglei
    Liu, Zhiyong
    CARBON MANAGEMENT, 2021, 12 (05) : 451 - 463
  • [23] Research on measurement of thickness and damage degree of coatings based on lock-in thermography
    Zhang, Jin-Yu
    Wu, Lan-Jie
    1ST INTERNATIONAL GLOBAL ON RENEWABLE ENERGY AND DEVELOPMENT (IGRED 2017), 2017, 100
  • [24] A new highly sensitive broadband ferromagnetic resonance measurement system with lock-in detection
    Beguhn, S.
    Zhou, Ziyao
    Rand, S.
    Yang, X.
    Lou, J.
    Sun, N. X.
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (07)
  • [25] Direct measurement of electrocaloric effect based on multi-harmonic lock-in thermography
    Iguchi, Ryo
    Fukuda, Daisuke
    Kano, Jun
    Teranishi, Takashi
    Uchida, Ken-ichi
    APPLIED PHYSICS LETTERS, 2023, 122 (08)
  • [26] Complex impedance measurement front-end based on an on/off lock-in amplifier
    Serrano-Finetti, Ernesto
    Hornero, Gemma
    Casas, Oscar
    PROCEEDINGS OF 2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0&IOT), 2022, : 419 - 423
  • [27] An Analog Lock-In Amplifier Based on Synchronous I/Q Demodulation for Capacitance Measurement
    Liang, Te
    Sun, Jiangtao
    Bai, Xu
    Shen, Mengxian
    Xu, Lijun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [28] Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices
    Barnard, Arthur W.
    Mikheev, Evgeny
    Finney, Joe
    Hiller, Han S.
    Goldhaber-Gordon, David
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (01):
  • [29] A NEW METHOD OF DYNAMIC ELECTRIC BIREFRINGENCE MEASUREMENT USING A SINUSOIDAL DIGITAL LOCK-IN SYSTEM
    OOKUBO, N
    MORI, Y
    HAYAKAWA, R
    WADA, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1980, 19 (11) : 2271 - 2278
  • [30] Portable Weak Magnetic Signal Detection System Based on Lock-in Amplifier
    Song, Junlei
    Tang, Xinda
    Dong, Kaifeng
    Wu, Tongyue
    Cui, Haozhe
    Jin, Fang
    Mo, Wenqin
    2020 12TH INTERNATIONAL CONFERENCE ON COMMUNICATION SOFTWARE AND NETWORKS (ICCSN 2020), 2020, : 276 - 279