Fatigue performance of perfobond shear connector in steel-concrete composite structure

被引:0
|
作者
机构
[1] Wei, Xing
[2] Xiao, Lin
[3] Shao, Ke-Fu
[4] Jiang, Su
来源
Wei, X. (we_star@swjtu.cn) | 1600年 / Chang'an University卷 / 26期
关键词
Orthotropic plates - Structure (composition) - Fatigue testing - Bridges - Concretes;
D O I
暂无
中图分类号
学科分类号
摘要
In order to investigate the fatigue performance of perfobond shear connectors in steel-concrete composite structure, according to the structure characteristics of perfobond shear connectors used in steel-concrete composite structure for different bridges, with opening of steel plate, diameter of steel bar and depth of steel plate as influence parameters, 24 push-out specimens in 6 groups were designed and orthotropic tests with 3 parameters in 2 levels were carried out. Based on the ultimate bearing capacity obtained by static push-out test, cycle numbers of different specimens suffering different loads were determined. Relation curves of cycle numbers and residual relative slip between steel and concrete were founded and fatigue damage evolution of perfobond shear connectors was divided into three stages. The results show that fatigue damage evolution of perfobond shear connectors can be described by residual relative slip, and fatigue damage and fatigue lifetime of perfobond shear connectors are determined by residual relative slip under different loads.
引用
收藏
相关论文
共 50 条
  • [41] Study on uplift performance of stud connector in steel-concrete composite structures
    Ju, Xiaochen
    Zeng, Zhibin
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (05): : 1279 - 1290
  • [42] Performance of headed stud on steel-concrete composite bridge deck as shear connector subjected to normal force
    Hoshina, Hiroto
    Fujiyama, Chikako
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 1294 - 1300
  • [43] Mechanical Properties Research of Steel-Concrete Composite Structure's connector
    Si, XiuYong
    Zhao, JianBo
    Bai, XiangZhong
    ADVANCED RESEARCH ON AUTOMATION, COMMUNICATION, ARCHITECTONICS AND MATERIALS, III, 2013, 738 : 128 - 132
  • [44] Shear behavior and design of an innovative embedded connector with flange for steel-concrete composite girder
    Zhang, Zhe
    Zhang, Sheng-Nan
    Deng, En-Feng
    Yu, Chen-Yang
    Tang, Yi
    Wang, Yan
    Sun, Dong-Sheng
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2022, 22 (04)
  • [45] Shear behavior of perfobond connectors in the steel-concrete joints of hybrid bridges
    Zou, Yang
    Di, Jin
    Zhou, Jianting
    Zhang, Zhongya
    Li, Xiujun
    Zhang, Hong
    Qin, Fengjiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
  • [46] Effect of Shear Connector Layout on the Behavior of Steel-Concrete Composite Beams with Interface Slip
    Zeng, Xinggui
    Jiang, Shao-Fei
    Zhou, Donghua
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [47] Random shear resistance of a headed-stud connector in composite steel-concrete beam
    Domanski, Tomasz
    Maslak, Mariusz
    ARCHIVES OF CIVIL ENGINEERING, 2024, 70 (04) : 425 - 439
  • [48] Mechanical behaviors of PBL shear connector group at steel-concrete composite truss joints
    Wang H.
    Du Y.
    1600, Chinese Academy of Railway Sciences (37): : 33 - 40
  • [49] Study on fatigue cracks in steel-concrete shear connection with composite dowels
    Dudzinski, W.
    Pekalski, G.
    Harnatkiewicz, P.
    Kopczynski, A.
    Lorenc, W.
    Kozuch, M.
    Rowinski, S.
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2011, 11 (04) : 839 - 858
  • [50] Study of Innovative Connector for Steel-Concrete Composite Structures
    Derlatka, Anna
    Lacki, Piotr
    Kania, Pawel
    Gao, Shan
    APPLIED SCIENCES-BASEL, 2024, 14 (07):