Cross-Calibration of RGB and Thermal Cameras with a LIDAR for RGB-Depth-Thermal Mapping

被引:14
|
作者
Krishnan A.K. [1 ]
Saripalli S. [2 ]
机构
[1] School of Earth and Space Exploration, Arizona State University, Tempe, AZ
[2] Department of Mechanical Engineering, Texas AandM University, College Station, TX
关键词
Cross-calibration; RGB thermal mapping; thermal cameras;
D O I
10.1142/S2301385017500054
中图分类号
学科分类号
摘要
We present a method for calibrating the extrinsic parameters between a RGB camera, a thermal camera, and a LIDAR. The calibration procedure we use is common to both the RGB and thermal cameras. The extrinsic calibration procedure assumes that the cameras are geometrically calibrated. To aid the geometric calibration of the thermal camera, we use a calibration target made of black-and-white melamine that looks like a checkerboard pattern in the thermal and RGB images. For the extrinsic calibration, we place a circular calibration target in the common field of view of the cameras and the LIDAR and compute the extrinsic parameters by minimizing an objective function that aligns the edges of the circular target in the LIDAR to its corresponding edges in the RGB and thermal images. We illustrate the convexity of the objective function and discuss the convergence of the algorithm. We then identify the various sources of coloring errors (after cross-calibration) as (a) noise in the LIDAR points, (b) error in the intrinsic parameters of the camera, (c) error in the translation parameters between the LIDAR and the camera and (d) error in the rotation parameters between the LIDAR and the camera. We analyze the contribution of these errors with respect to the coloring of a 3D point. We illustrate that these errors are related to the depth of the 3D point considered - with errors (a), (b), and (c) being inversely proportional to the depth, and error (d) being directly proportional to the depth. © 2017 World Scientific Publishing Company.
引用
收藏
页码:59 / 78
页数:19
相关论文
共 50 条
  • [41] Nonlinear RGB-to-XYZ mapping for device calibration
    Xiong, WH
    Funt, B
    THIRTEENTH COLOR IMAGING CONFERENCE, FINAL PROGRAM AND PROCEEDINGS: COLOR SCIENCE AND ENGINEERING SYSTEMS, TECHNOLOGIES, AND APPLICATIONS, 2005, : 200 - 204
  • [42] Enhanced Depth Map Estimation in Low Light Conditions for RGB Cameras
    Chang, Joseph
    Nguyen, Truong Q.
    18TH INTERNATIONAL SOC DESIGN CONFERENCE 2021 (ISOCC 2021), 2021, : 21 - 22
  • [43] RGBDTCalibNet: End-to-end Online Extrinsic Calibration between a 3D LiDAR, an RGB Camera and a Thermal Camera
    Mharolkar, Sanat
    Zhang, Jun
    Peng, Guohao
    Liu, Yiyao
    Wang, Danwei
    2022 IEEE 25TH INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION SYSTEMS (ITSC), 2022, : 3577 - 3582
  • [44] 3D Thermal Mapping of Building Interiors using an RGB-D and Thermal Camera
    Vidas, Stephen
    Moghadam, Peyman
    Bosse, Michael
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 2311 - 2318
  • [45] HJ-1A THERMAL INFRARED BAND CROSS-CALIBRATION AND VALIDATION
    Li, Jiaguo
    Gu, Xingfa
    Zhu, Li
    Yu, Tao
    Li, Xiaoying
    Zhang, Yuxiang
    Gao, Hailiang
    Gong, Hui
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 2167 - +
  • [46] Multimodal Emotion Recognition with Thermal and RGB-D Cameras for Human-Robot Interaction
    Yu, Chuang
    Tapus, Adriana
    HRI'20: COMPANION OF THE 2020 ACM/IEEE INTERNATIONAL CONFERENCE ON HUMAN-ROBOT INTERACTION, 2020, : 532 - 534
  • [47] Radiometric cross-calibration of CBERS-02 IRMSS thermal channel
    National Satellite Meteorology Center, China Meteorological Administration, Beijing 100081, China
    不详
    不详
    不详
    不详
    Hongwai Yu Haomibo Xuebao, 2006, 4 (261-266):
  • [48] Radiometric cross-calibration of CBERS-02 IRMSS thermal channel
    Zhang Yong
    Gu Xing-Fa
    Yu Tao
    Zhang Yu-Xiang
    Qi Rui-Li
    Li Xiao-Wen
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 25 (04) : 261 - 266
  • [49] A Fast Visual Odometry and Mapping System for RGB-D Cameras
    Silva, Bruno M. F.
    Goncalves, Luiz M. G.
    2014 2ND BRAZILIAN ROBOTICS SYMPOSIUM (SBR) / 11TH LATIN AMERICAN ROBOTICS SYMPOSIUM (LARS) / 6TH ROBOCONTROL WORKSHOP ON APPLIED ROBOTICS AND AUTOMATION, 2014, : 55 - 60
  • [50] A Method of Simultaneous Location and Mapping Based on RGB-D Cameras
    Liu, Xin
    Guo, Baiwei
    Meng, Chao
    2016 14TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION (ICARCV), 2016,