Effect of different implant configurations on biomechanical behavior of full-arch implant-supported mandibular monolithic zirconia fixed prostheses

被引:0
|
作者
Zhong, Jingxiao [1 ]
Guazzato, Massimiliano [2 ]
Chen, Junning [1 ,3 ]
Zhang, Zhongpu [4 ]
Sun, Guangyong [1 ,5 ]
Huo, Xintao [5 ]
Liu, Xinglong [5 ]
Ahmad, Rohana [6 ]
Li, Qing [1 ]
机构
[1] School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Australia
[2] Discipline of Prosthodontics, Faculty of Dentistry, Westmead Centre for Oral Health, Westmead Hospital, Australia
[3] College of Engineering, Mathematics and Physical Sciences, University of Exeter, United Kingdom
[4] School of Computing, Engineering and Mathematics, Western Sydney University, Penrith,NSW,2751, Australia
[5] State Key Laboratory of Advanced Design and Manufacture for Vehicle Body, Hunan University, Changsha,410082, China
[6] Unit of Prosthodontics, Faculty of Dentistry, Universiti Teknologi MARA, Sg Buloh,47000, Malaysia
基金
澳大利亚研究理事会;
关键词
Clinical research - Dental prostheses - Zirconia - Failure (mechanical) - Stress analysis - Biomechanics - Stress concentration - Finite element method;
D O I
暂无
中图分类号
学科分类号
摘要
Mechanical failure of zirconia-based full-arch implant-supported fixed dental prostheses (FAFDPs) remains a critical issue in prosthetic dentistry. The option of full-arch implant treatment and the biomechanical behaviour within a sophisticated screw-retained prosthetic structure have stimulated considerable interest in fundamental and clinical research. This study aimed to analyse the biomechanical responses of zirconia-based FAFDPs with different implant configurations (numbers and distributions), thereby predicting the possible failure sites and the optimum configuration from biomechanical aspect by using finite element method (FEM). Five 3D finite element (FE) models were constructed with patient-specific heterogeneous material properties of mandibular bone. The results were reported using volume-averaged von-Mises stresses (σVMVA) to eliminate numerical singularities. It was found that wider placement of multi-unit copings was preferred as it reduces the cantilever effect on denture. Within the limited areas of implant insertion, the adoption of angled multi-unit abutments allowed the insertion of oblique implants in the bone and wider distribution of the multi-unit copings in the prosthesis, leading to lower stress concentration on both mandibular bone and prosthetic components. Increasing the number of supporting implants in a FAFDPs reduced loading on each implant, although it may not necessarily reduce the stress concentration in the most posterior locations significantly. Overall, the 6-implant configuration was a preferable configuration as it provided the most balanced mechanical performance in this patient-specific case. © 2019
引用
收藏
相关论文
共 50 条
  • [21] Fixed Full-Arch Implant-Supported Prostheses in a Patient with Epidermolysis Bullosa: A Clinical Case History Report
    Agustin-Panadero, Ruben
    Gomar-Vercher, Sonia
    Penarrocha-Oltra, David
    Guzman-Letelier, Marcelo
    Penarrocha-Diago, Miguel
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (01) : 33 - 36
  • [22] Full-arch implant-supported rehabilitations: A prospective study comparing porcelain-veneered zirconia frameworks to monolithic zirconia
    Carames, Joao
    Marques, Duarte
    Barbosa, Joao Malta
    Moreira, Andre
    Crispim, Pedro
    Chen, Andre
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (01) : 68 - 78
  • [23] Implant-supported full-arch zirconia-based mandibular fixed dental prostheses. Eight-year results from a clinical pilot study
    Larsson, Christel
    Von Steyern, Per Vult
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1118 - 1122
  • [24] A Prospective Study of Implant-Supported Full-Arch Yttria-Stabilized Tetragonal Zirconia Polycrystal Mandibular Fixed Dental Prostheses: Three-Year Results
    Larsson, Christel
    von Steyern, Per Vult
    Nilner, Krister
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 364 - 369
  • [25] Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques
    Zaparolli, Danilo
    Peixoto, Raniel Fernandes
    Pupim, Denise
    Macedo, Ana Paula
    Toniollo, Marcelo Bighetti
    Chiarello de Mattos, Maria da Gloria
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 81 : 144 - 147
  • [26] Assessment of the efficacy of posterior extra-short implant support for an interforaminal implant-supported fixed full-arch mandibular prosthesis
    Tukel, H. Can
    Kucukkurt, S.
    JOURNAL OF OSSEOINTEGRATION, 2020, 12 (02) : 181 - 188
  • [27] Retrieval Technique for Full-Arch Implant-Supported Fixed Prosthesis: A Clinical Report
    Simamoto-Junior, Paulo Cesar
    Fernandes-Neto, Alfredo Julio
    Neves, Flavio Domingues
    Dantas, Talita Souza
    Naves, Lucas Zago
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02): : 168 - 171
  • [28] Fixed Full-Arch Implant-Supported Restorations: Techniques Review and Proposal for Improvement
    Froimovici, Florin-Octavian
    Butnarasu, Cristian Corneliu
    Montanari, Marco
    Sandulescu, Mihai
    DENTISTRY JOURNAL, 2024, 12 (12)
  • [29] Fixed Implant-Supported Full-Arch Prosthesis in Epidermolysis Bullosa With Severe Symptoms
    Guzman Letelier, Marcelo
    Crisosto Jara, Claudia
    Penarrocha-Oltra, Sonia
    Gomar-Vercher, Sonia
    Penarrocha Diago, Miguel
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (06) : 499 - 504
  • [30] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):