Temperature distribution of room fire and window spill flame with a slope constrain

被引:0
|
作者
Tang, Fei [1 ]
Hu, Long-Hua [1 ]
Zhu, Wei [2 ]
Lu, Kai-Hua [1 ]
Ao, Da-Cheng [1 ]
机构
[1] State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China
[2] Beijing Research Center of Urban System Engineering, Beijing 100089, China
关键词
Fire protection - Hazardous materials spills - Fires - Combustion;
D O I
暂无
中图分类号
学科分类号
摘要
A reduced model is developed to study room fire window spill flame behavior, and square gasoline pool fires with the lengths of 15 cm, 25 cm and 35 cm are used as fire sources. The room fire and window spill flame temperature distributions are investigated under the constrain slopes of 0°, 45°, 60° and 75°. Results shows that, with the increase of slope angle, for the small fire(15 cm), the combustion within the room remains relatively complete so that temperature distributions of room fire and window spill plume change little; for the large fire(35 cm), the combustion within the room is relatively incomplete, a large amount of flame is observed to spill out through the opening, and spill flame temperature is high and also changes little; however, for the medium fire(25 cm), the influence of slope is remarkable, the combustion within the room transfers from relatively complete to incomplete, the room temperature both along the center line and in the corner near the window decreases, while that in the inner corner increases, and spill flame temperature and height are shown to increase greatly. When flame is observed to spill out directly, there exists a special low temperature domain for the vertical temperature distribution near the wall.
引用
收藏
页码:243 / 249
相关论文
共 50 条
  • [41] Experimental study on the ceiling jet characteristics caused by carriage fire in an inclined tunnel: Temperature distribution and flame extension
    Xu, Tong
    Tang, Fei
    Zhang, Jianping
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [42] Effect of Room Temperature in Storage On Outward Bowing of Phantom Window
    Kinoshita, N.
    Oguchi, H.
    Nishimoto, Y.
    Adachi, T.
    Shioura, H.
    Kimura, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 2932 - 2933
  • [43] Temperature distribution of trapezoidal sheeting in fire
    Cábová, Kamila
    Lišková, Nikola
    Arha, Tesfamariam
    Malaska, Mikko
    Alanen, Mika
    Mela, Kristo
    Pajunen, Sami
    Wald, František
    ce/papers, 2019, 3 (3-4): : 665 - 670
  • [44] Flame spread and smoke temperature of full-scale fire test of car fire
    Li, Dayan
    Zhu, Guoqing
    Zhu, Hui
    Yu, Zhichao
    Gao, Yunji
    Jiang, Xiaohui
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 315 - 324
  • [45] Study on the flame behavior of ethanol spill fire on base plate with different width in longitudinal ventilation environment
    Zhang, Peihong
    Ye, Chenghao
    Jiang, Xue
    Hu, Xuejing
    Xia, Meiqing
    Li, Jiaxing
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2025, 155
  • [46] An experimental study on flame characteristic of spill fire plumes for atypical openings under external sideward wind
    Zhang, Xiaochun
    Cheng, Zhangkun
    Ren, Fei
    Chen, Linjie
    Zhou, Geyao
    Lyu, Baien
    Zhang, Zijian
    Zhao, Zhe
    JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [47] Phenomenological characteristics and flame radiation of dynamically evolving oil spill fires in a sealed ship engine room
    Liu, Jiahao
    Wang, Zhe
    Lu, Kaifei
    Zhang, Ruiqing
    Li, Haihang
    Zhang, Shaogang
    Wang, Jinhui
    OCEAN ENGINEERING, 2023, 267
  • [48] Effects of surface flame spread of block board lining on enclosure fire in ISO room corner fire test
    Yang, Y
    Zhang, HP
    Xu, L
    Wang, W
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1201 - 1207
  • [49] Spread law and temperature distribution of spill fires in confined space
    Jiao W.
    Chen C.
    Du W.
    Shi L.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2024, 64 (06): : 1016 - 1023
  • [50] A study on window plume from a room fire to the cavity of a double-skin facade
    Miao, Lei
    Chow, Cheuk Lun
    APPLIED THERMAL ENGINEERING, 2018, 129 : 230 - 241