Study on magnetic resonance imaging of gaseous medium (1st report, imaging of pressurized gas and influence of molecular diffusion on imaging)

被引:0
|
作者
Tsushima, Shohji [1 ]
Hirai, Shuichiro [1 ]
Iriguchi, Norio [1 ]
Okamoto, Ikuo [1 ]
Suekane, Tetsuya [1 ]
机构
[1] Res. Ctr. Carbon Recycling Utiliz., Tokyo Institute of Technology, 2-12-1 Ohokayama, Meguro-ku, Tokyo 152-8552, Japan
关键词
Diffusion - Methane - Nuclear magnetic resonance - Porous materials;
D O I
10.1299/kikaib.68.556
中图分类号
学科分类号
摘要
In this article, application of magnetic resonance (MR) imaging to pressurized gas is described. A specially-designed non-magnetic test vessel offers cylindrical sample chamber with 12 mm i.d. and 114 mm in length, in which methane gas was supplied up to 10.0 MPa in order to investigate its feasibility of gas MR imaging. Experiments with glass beads were also conducted and it is shown that MR imaging technique successfully produces methane images with glass beads owing to high proton density at pressurized fields. Furthermore, hydrogen gas was used instead of methane in an effort to examine influence of gaseous properties on gas MR imaging. It is shown that signal intensity on MR images of hydrogen was much less than that of methane due to high diffusivity of hydrogen molecules, which was also confirmed by numerical calculation.
引用
收藏
页码:556 / 561
相关论文
共 50 条
  • [31] Magnetic Resonance Imaging and Diffusion Weighted Imaging appearance of cerebellar liponeurocytoma
    Guan, J. T.
    Guo, G.
    Geng, Y. Q.
    Xu, X. H.
    Yu, X. J.
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 123 - +
  • [32] Cerebellar imaging with diffusion magnetic resonance imaging: approaches, challenges, and potential
    Lundell, Henrik
    Steele, Christopher J.
    CURRENT OPINION IN BEHAVIORAL SCIENCES, 2024, 56
  • [33] Diffusion-weighted imaging in pediatric body magnetic resonance imaging
    Govind B. Chavhan
    Pablo Caro-Dominguez
    Pediatric Radiology, 2016, 46 : 847 - 857
  • [34] Interreader agreement in the assessment of magnetic resonance Imaging of the sacroiliac joints in spondyloarthropathy - The 1st MISS study.
    Marzo-Ortega, H
    ARTHRITIS AND RHEUMATISM, 2002, 46 (09): : S428 - S428
  • [35] WHOLE-BODY NUCLEAR MAGNETIC-RESONANCE IMAGING - THE 1ST REPORT OF ITS USE IN SURGICAL PRACTICE
    POLLET, JE
    SMITH, FW
    MALLARD, JR
    AHSEE, AK
    REID, A
    BRITISH JOURNAL OF SURGERY, 1981, 68 (07) : 493 - 494
  • [36] A Preliminary Study of the Geometric Distortion in Diffusion-Weighted Imaging of Magnetic Resonance Imaging Simulation
    Liu, X.
    Qiu, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E510 - E510
  • [37] Cortical Reorganization Following Neurotization: A Diffusion Tensor Imaging and Functional Magnetic Resonance Imaging Study
    Sokki, Anilkumar Masalavada
    Bhat, Dhananjaya Ishwar
    Devi, Bhagavatula Indira
    NEUROSURGERY, 2012, 70 (05) : 1305 - 1311
  • [38] Preliminary Study of Diffusion-Weighted Imaging and Magnetic Resonance Spectroscopy Imaging in Kimura Disease
    Wang, Jie
    Tang, Zuohua
    Feng, Xiaoyuan
    Zeng, Wenjiao
    Tang, Weijun
    Wu, Lingjie
    Jin, Lixin
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (06) : 2147 - 2151
  • [39] Magnetic resonance molecular imaging with nanoparticles
    Gregory M. Lanza
    Patrick M. Winter
    Shelton D. Caruthers
    Anne M. Morawski
    Anne H. Schmieder
    Katherine C. Crowder
    Samuel A. Wickline
    Journal of Nuclear Cardiology, 2004, 11 : 733 - 743
  • [40] Magnetic resonance molecular imaging with nanoparticles
    Lanza, GM
    Winter, PM
    Caruthers, SD
    Morawski, AM
    Schmieder, AH
    Crowder, KC
    Wickline, SA
    JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (06) : 733 - 743