The measuring and decoding capacities of digital X-ray image

被引:0
|
作者
Mishkinis, A.B. [1 ]
Chernij, A.N. [1 ]
Bagaeva, N.G. [1 ]
Il'icheva, E.Yu. [1 ]
机构
[1] Gellik, Moscow, Russia
来源
Meditsinskaya Tekhnika | 2002年 / 02期
关键词
Diagnosis - Digital signal processing - Image processing - Medical computing - Medical imaging - Pulmonary diseases;
D O I
暂无
中图分类号
学科分类号
摘要
The paper deals with the theory and practice of digital X-ray diagnosis. The adverse factors of formation of a digital X-ray film are considered. They included geometric and dynamic indistinctness, indistinctness of an image receiver, and the contrast and dynamic range of digital image. Analysis of a great deal of clinical data shows the capacities of digital X-ray study to diagnose different forms of pulmonary tuberculosis and other thoracic diseases.
引用
收藏
页码:20 / 24
相关论文
共 50 条
  • [31] Digital x-ray image processing algorithms for clinical parameters extraction
    D'Amico, M.
    D'Amico, G.
    Roncoletta, P.
    Studies in Health Technology and Informatics, 1997, 37 : 239 - 242
  • [32] Investigation of the Variability in the Assessment of Digital Chest X-ray Image Quality
    Whaley, Jacquelyn S.
    Pressman, Barry D.
    Wilson, Jonathan R.
    Bravo, Lionel
    Sehnert, William J.
    Foos, David H.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (02) : 217 - 226
  • [33] Comparison of analog and digital magnification in x-ray fluoroscopy image sequences
    Srinivas, Y
    Wilson, DL
    MEDICAL IMAGING 2002: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2002, 4686 : 129 - 138
  • [34] Investigation of the Variability in the Assessment of Digital Chest X-ray Image Quality
    Jacquelyn S. Whaley
    Barry D. Pressman
    Jonathan R. Wilson
    Lionel Bravo
    William J. Sehnert
    David H. Foos
    Journal of Digital Imaging, 2013, 26 : 217 - 226
  • [35] Microelectronic devices digital X-ray image processing method development
    Staroverov, N. E.
    Gryaznov, A. Yu
    Kholopova, E. D.
    Guk, K. K.
    4TH INTERNATIONAL CONFERENCE ON X-RAY AND ELECTROVACUUM TECHNIQUE, 2017, 2018, 967
  • [36] Analysis of frequency - Contrast characteristics of digital X-ray image detectors
    Zelikman M.I.
    Kabanov S.P.
    Kokuev A.N.
    Kruchinin S.A.
    Lobov D.P.
    Biomedical Engineering, 2006, 40 (5) : 237 - 240
  • [37] Research on tomato seed vigor based on X-ray digital image
    Zhao Xueguan
    Gao Yuanyuan
    Wang Xiu
    Li Cuiling
    Wang, Songlin
    Feng Qingcun
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY IV, 2016, 10020
  • [38] Digital X-ray image processing using biologically inspired methods
    Lindblad, T
    Lindsey, CS
    Padgett, ML
    Vanyachine, A
    Zanevsky, Y
    IEEE WORLD CONGRESS ON COMPUTATIONAL INTELLIGENCE, 1998, : 803 - 808
  • [39] Digital imaging with solid-state x-ray image intensifiers
    Damento, MA
    Radspinner, R
    Roehrig, H
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 122 - 133
  • [40] Development Of Image Acquisition Software for Digital Radiograph and X-Ray CT
    Suryaningsih, Fitri
    Handoyo, Demon
    Susanto, Andeka Tris
    SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018), 2019, 1198