Performance of a BeO-based dosimetry system for proton and electron beam dose measurements

被引:0
|
作者
Bossin, Lily [1 ]
Dal Bello, Riccardo [2 ,3 ]
Christensen, Jeppe Brage [1 ]
Schischke, Stefan [4 ]
Motta, Silvia [1 ]
Togno, Michele [5 ]
Yukihara, Eduardo Gardenali [1 ]
机构
[1] Paul Scherrer Inst, Dept Radiat Safety & Secur, Villigen, Switzerland
[2] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[3] Univ Zurich, Zurich, Switzerland
[4] Radpro, Remscheid, Germany
[5] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
关键词
OSL dosimetry; Proton dosimetry; Electron dosimetry; Ultra-high dose rate; Dosimetry system; BeO; OPTICALLY STIMULATED LUMINESCENCE; BERYLLIUM-OXIDE; RATE DEPENDENCE; OSL; THERMOLUMINESCENCE;
D O I
10.1016/j.radmeas.2024.107310
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study aims to evaluate the performance of the BeO-based myOSLchip system (RadPro International GmbH, Remscheid, Germany) for dosimetry of proton and electron radiotherapy beams. Although beryllium oxide (BeO) has been recognised as a promising material for luminescence dosimetry in radiotherapy, this research extends beyond material properties and examines the entire BeO-based dosimetry system, including the detector, holder, and readout components. Packages of myOSLchip dosimeters were irradiated either in a ( 70-230 ) MeV proton beam or in a 16 MeV electron beam. The readouts were carried out using the portable myOSLchip reader. In the electron beam, tests on the precision, dose response up to 100 Gy and dose-rate effects of the system were carried out. In the proton beam, the system was tested for its dose response (up to 10 Gy), fading, and linear energy transfer (LET) response. For proton irradiations, the myOSLchip BeO OSLDs exhibited stability within 2% over 135 days, as well as a linear dose response in the tested range, (0.1 - 10) Gy. The efficiency showed a reduction for proton beams with LET values (for water) above 0.6 keV/mu m, with up to 40% loss inefficiency at 4 keV/mu m. For the electron irradiations, they showed a linear dose-response up to 20 Gy and dose-rate independence, with a constant response at least up to 2.99 x 105 Gy s-1. Using individual dosimeter sensitivity correction, the precision fora single dosimeter was around 3.5% (standard deviation of the data of all dosimeters) and fora package comprising four dosimeters was 1.7% (standard deviation of the mean of the four dosimeters). These findings suggest the myOSLchip system's potential as a reliable alternative to existing dosimetry systems in clinical applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Prototype system for proton beam range measurement based on gamma electron vertex imaging
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Jung, Won Gyun
    Lim, Hansang
    Kim, Chan Hyeong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 82 - 97
  • [42] Dose error analysis for a scanned proton beam delivery system
    Coutrakon, G.
    Wang, N.
    Miller, D. W.
    Yang, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 7081 - 7096
  • [43] Measurements and analysis of beam current and beam diameter of an electron beam lithography system
    Lu, W
    Ng, GI
    Yoon, SF
    Shen, HY
    MICROLITHOGRAPHIC TECHNIQUES IN IC FABRICATION, 1997, 3183 : 161 - 168
  • [44] First application of total skin electron beam irradiation in Greece: Setup, measurements and dosimetry
    Platoni, K.
    Diamantopoulos, S.
    Panayiotakis, G.
    Kouloulias, V.
    Pantelakos, P.
    Kelekis, N.
    Efstathopoulos, E.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 174 - 182
  • [45] Dose Perturbation Caused by MOSFET Dosimeter during in Vivo Dosimetry of Photon and Electron Beam Radiotherapy - a Film Dosimetry Study
    Manigandan, D.
    Ganesan, S.
    Aruna, P.
    Bharandharani, G.
    Subramani, V.
    Sharma, S.
    Rath, G.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [46] Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy
    Santos, Alexandre M. Caraca
    Mohammadi, Mohammad
    Afshar, Shahraam, V
    MEDICAL PHYSICS, 2015, 42 (11) : 6349 - 6356
  • [47] Use of BANG® polymer gel for dose measurements in a 68 MeV proton beam
    Heufelder, J
    Stiefel, S
    Pfaender, M
    Lüdemann, L
    Grebe, G
    Heese, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1235 - 1240
  • [48] Measurements and simulations of in-phantom neutron dose from a proton pencil beam
    Ytre-Hauge, K. S.
    Velure, A.
    Stokkevag, C. H.
    Odland, O. H.
    Rohrich, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S116 - S117
  • [49] Reference dosimetry of proton pencil beams based on dose-area product
    Goma, C.
    Safai, S.
    Voros, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S28 - S29
  • [50] A Feasibility Study of a Monte Carlo Based Dose Verification for a Therapeutic Proton Beam Delivery System
    Shin, Jungwook
    Kwak, Jungwon
    Kim, Dong Wook
    Shin, Dongho
    Yoon, Myongguen
    Park, Soah
    Lim, Young Kyung
    Kim, Jin Sung
    Park, Sung Yong
    Cho, Kwan Ho
    Lee, Se Byeong
    MEDICAL PHYSICS, 2008, 35 (06)