Automated identification of the modal parameters of a cable-stayed bridge: Influence of the wind conditions

被引:0
|
作者
Magalhães F. [1 ]
Cunha Á. [1 ]
机构
[1] CONSTRUCT - ViBest, Faculty of Engineering, University of Porto (FEUP), Rua Dr. Roberto Frias, Porto
来源
Magalhães, Filipe (filipema@fe.up.pt) | 1600年 / Techno-Press卷 / 17期
关键词
Automated operational modal analysis; Benchmark study; Cable-stayed bridge;
D O I
10.12989/sss.2016.17.3.431
中图分类号
学科分类号
摘要
This paper was written in the context of a benchmark study promoted by The Hong Kong Polytechnic University using data samples collected in an instrumented cable-stayed bridge. The main goal of the benchmark test was to study the identification of the bridge modes of vibration under different wind conditions. In this contribution, the tools developed at ViBest/FEUP for automated data processing of setups collected by dynamic monitoring systems are presented and applied to the data made available in the context of the benchmark study The applied tools are based on parametric output only modal identification methods combined with clustering algorithms. The obtained results demonstrate that the proposed algorithms succeeded to automatically identify the modes with relevant contribution for the bridge response under different wind conditions. © Copyright 2016 Techno-Press, Ltd.
引用
收藏
页码:431 / 444
页数:13
相关论文
共 50 条
  • [21] Experimental modal analysis of the Garigliano cable-stayed bridge
    Clemente, P
    Marulo, F
    Lecce, L
    Bifulco, A
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 1998, 17 (7-8) : 485 - 493
  • [22] Modal flexibility analysis of cable-stayed Ting Kau bridge for damage identification
    Ni, Y. Q.
    Zhou, H. F.
    Chan, K. C.
    Ko, J. M.
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2008, 23 (03) : 223 - 236
  • [23] Based modal analysis evaluation of a cable-stayed bridge
    Escobar, JA
    Gómez, R
    Murià-Vila, D
    Sánchez-Ramírez, R
    IMAC-XVIII: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, PROCEEDINGS, 2000, 4062 : 821 - 826
  • [24] Based modal analysis evaluation of a cable-stayed bridge
    Escobar, J.Alberto
    Gomez, Roberto
    Muria-Vila, David
    Sanchez-Ramirez, Roberto
    Proceedings of the International Modal Analysis Conference - IMAC, 2000, 1 : 821 - 826
  • [25] Modal interaction in cable-stayed Ting Kau Bridge
    Ni, YQ
    Wang, JY
    Ko, JM
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 537 - 544
  • [26] Modal analysis of a partially constructed cable-stayed bridge
    Macdonald, JHG
    Dobinson, NS
    Macnamara, HJ
    Taylor, CA
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 1367 - 1373
  • [27] Finite Element Modal Analysis of the Cable-stayed Bridge
    Wu, Jilin
    Song, Chuncao
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 883 - 885
  • [28] Technology and Application for Modal testing of Cable-stayed Bridge
    Zou, Yi Song
    Chang, Quan Hui
    Peng, Wei
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 396 - +
  • [29] Damage identification in cable-stayed bridge based on modal analysis and neural networks
    Zhang, Xiedong
    Zhang, Zhiguo
    Li, Xiaofan
    Zhan, Hao
    Review of Progress in Quantitative Nondestructive Evaluation, Vols 26A and 26B, 2007, 894 : 1435 - 1442
  • [30] Modal parameters identification of cable-stayed bridges with close-spaced modes
    Cherng, Rwey-Hua
    Chaung, Chun-Shu
    Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2007, 19 (04): : 557 - 566