Investigation of the performance of oil-free linear compressor with magnetic resonance spring for pulse tube cryocooler

被引:1
|
作者
Tang, Mingsheng [1 ,3 ]
Hu, Zhouhang [1 ,2 ,3 ]
Chen, Liubiao [1 ,3 ]
Wu, Yongheng [4 ]
Xiao, Jianhua [4 ]
Yuan, Qingqing [4 ]
Zou, Huiming [1 ,3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Key Lab Cryogen Sci & Technol, Beijing 100190, Peoples R China
[4] Huangshi Donper Compressor CO LTD, Huangshi 435000, Hubei, Peoples R China
关键词
Pulse tube cryocooler; Linear compressor; Magnetic spring; Gas spring; Frequency characteristic; DRIVEN;
D O I
10.1016/j.cryogenics.2024.103982
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study proposes a new type of oil-free linear compressor with a magnetic resonance spring, which uses a magnetic resonance spring to provide restoring force and adopts gas-lubricated bearings to provide support force for the piston. The frequency characteristics of the compressor, including magnetic spring stiffness, gas spring stiffness, and resonance frequency, are studied through experiments and theoretical analysis. The magnetic spring stiffness is 31403.31 N/m of the design compressor. Hooke's law and Fourier decomposition are employed for the gas spring stiffness measuring the compression pressure gauged. Meanwhile, the gas spring stiffness is also obtained from the amplitude-frequency characteristic of the compressor by the back stepping technique with an electric parameter frequency scan. The experimental results demonstrate that the three measurement methods have good consistency in measuring the gas spring stiffness. The equivalent gas spring stiffness measured using the three methods and theoretical model are 72600.92 N/m, 71275.84 N/m, 71967.15 N/m, and 71929.25 N/m at 3 MPa charged pressure measured respectively. In addition, the refrigeration performance of the pulse tube cryocooler driven by the compressor is tested and the lowest temperature obtained in the cold end is 46.3 K under different charge pressure. Furthermore, an optimal frequency exists that enhances the refrigeration performance of the pulse tube cryocooler, and this optimal frequency remains constant regardless of changes in the charge pressure.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental Analysis of the Discharge Valve Movement of the Oil-Free Linear Compressor in the Refrigeration System
    Li, Chengzhan
    Sun, Jian
    Zou, Huiming
    Cai, Jinghui
    Zhu, Tingting
    SUSTAINABILITY, 2023, 15 (07)
  • [32] Scrutinizing the sources of inefficiencies in the piston-cylinder clearance of an oil-free linear compressor
    Santos, Claudio J.
    Dutra, Thiago
    Deschamps, Cesar J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 513 - 520
  • [33] Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization of cold energy
    Xuming Liu
    Xiafan Xu
    Biao Yang
    Xiaotong Xi
    Liubiao Chen
    Junjie Wang
    Yuan Zhou
    Frontiers in Energy, 2021, 15 : 345 - 357
  • [34] Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization of cold energy
    Liu, Xuming
    Xu, Xiafan
    Yang, Biao
    Xi, Xiaotong
    Chen, Liubiao
    Wang, Junjie
    Zhou, Yuan
    FRONTIERS IN ENERGY, 2021, 15 (02) : 345 - 357
  • [35] Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization of cold energy
    Xuming LIU
    Xiafan XU
    Biao YANG
    Xiaotong XI
    Liubiao CHEN
    Junjie WANG
    Yuan ZHOU
    Frontiers in Energy, 2021, (02) : 345 - 357
  • [36] RESEARCH ON SEALING PERFORMANCE IN HIGH PRESSURE OIL-FREE MINIATURE AIR COMPRESSOR
    Deng, Yipan
    Liu, Yinshui
    Li, Fan
    Tian, Pengyun
    Miao, Na
    PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2017, 2017,
  • [37] Dynamic behavior analysis of a moving coil oil-free linear compressor in refrigeration system
    Li, Chengzhan
    Zou, Huiming
    Cai, Jinghui
    Jiang, Yuyan
    Guo, Chaohong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 235 - 246
  • [38] Analysis of oil-free linear compressor operated at high pressure ratios for household refrigeration
    Liang, Kun
    ENERGY, 2018, 151 : 324 - 331
  • [39] Experimental studies on a high-efficiency pulse tube cryocooler driven by an oil-lubricated compressor
    Ren, Jia
    Hu, Jian-Ying
    Luo, Er-Cang
    Dai, Wei
    Wang, Xiao-Tao
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (11): : 1821 - 1824
  • [40] Modeling and measurement of a moving coil oil-free linear compressor performance for refrigeration application using R134a
    Jomde, Amit
    Anderson, A.
    Bhojwani, Virendra
    Kedia, Shreyans
    Jangale, Nitish
    Kolas, Kshitij
    Khedkar, Pravin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 182 - 194