Investigation of the performance of oil-free linear compressor with magnetic resonance spring for pulse tube cryocooler

被引:1
|
作者
Tang, Mingsheng [1 ,3 ]
Hu, Zhouhang [1 ,2 ,3 ]
Chen, Liubiao [1 ,3 ]
Wu, Yongheng [4 ]
Xiao, Jianhua [4 ]
Yuan, Qingqing [4 ]
Zou, Huiming [1 ,3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Key Lab Cryogen Sci & Technol, Beijing 100190, Peoples R China
[4] Huangshi Donper Compressor CO LTD, Huangshi 435000, Hubei, Peoples R China
关键词
Pulse tube cryocooler; Linear compressor; Magnetic spring; Gas spring; Frequency characteristic; DRIVEN;
D O I
10.1016/j.cryogenics.2024.103982
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study proposes a new type of oil-free linear compressor with a magnetic resonance spring, which uses a magnetic resonance spring to provide restoring force and adopts gas-lubricated bearings to provide support force for the piston. The frequency characteristics of the compressor, including magnetic spring stiffness, gas spring stiffness, and resonance frequency, are studied through experiments and theoretical analysis. The magnetic spring stiffness is 31403.31 N/m of the design compressor. Hooke's law and Fourier decomposition are employed for the gas spring stiffness measuring the compression pressure gauged. Meanwhile, the gas spring stiffness is also obtained from the amplitude-frequency characteristic of the compressor by the back stepping technique with an electric parameter frequency scan. The experimental results demonstrate that the three measurement methods have good consistency in measuring the gas spring stiffness. The equivalent gas spring stiffness measured using the three methods and theoretical model are 72600.92 N/m, 71275.84 N/m, 71967.15 N/m, and 71929.25 N/m at 3 MPa charged pressure measured respectively. In addition, the refrigeration performance of the pulse tube cryocooler driven by the compressor is tested and the lowest temperature obtained in the cold end is 46.3 K under different charge pressure. Furthermore, an optimal frequency exists that enhances the refrigeration performance of the pulse tube cryocooler, and this optimal frequency remains constant regardless of changes in the charge pressure.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Performance of G-M cryocooler with oil-free linear compressor
    Maddocks, J. R.
    Kashani, A.
    Helvensteijn, B. P. M.
    Hoch, D. W.
    Nellis, G. F.
    Corey, J. A.
    James, E. L.
    Rhoads, G. L.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 696 - +
  • [2] The design of linear compressor driven pulse tube cryocooler
    Jing, W
    Hou, YK
    Ju, YL
    Liang, JT
    Cai, JH
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 109 - 112
  • [3] Cooling power analysis of a small scale 4 K pulse tube cryocooler driven by an oil-free low input power Helium compressor
    Schmidt, J-A
    Schmidt, B.
    Falter, J.
    Hoehne, J.
    Dal Savio, C.
    Schaile, S.
    Schirmeisen, A.
    ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023, 2024, 1301
  • [4] Performance estimation of an oil-free linear compressor unit for a new compact 2K Gifford-McMahon cryocooler
    Hiratsuka, Y.
    Bao, Q.
    Xu, M. Y.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [5] PERFORMANCE OF AN OIL-FREE LINEAR COMPRESSOR USING R1234yf
    Li, Zhaohua
    Liang, Kun
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 194 - 202
  • [6] Thermal modelling and analysis of an oil-free linear compressor
    Oliveira, M. J.
    Diniz, M. C.
    Deschamps, C. J.
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2015, 90
  • [7] Ultrareliable pulse tube cryocooler with a flexure bearings linear drive compressor
    Curlier, P
    INFRARED TECHNOLOGY AND APPLICATIONS XXII, 1996, 2744 : 302 - 307
  • [8] Study of a 300 Hz pulse tube cryocooler driven by a linear compressor
    Wang, X.-T. (dwpeng@yahoo.com), 1600, Science Press (35):
  • [9] Numerical investigation on the thermoacoustics characteristics of thermal compressor for the pulse tube cryocooler
    Pan, Changzhao
    Wang, Jue
    Zhang, Tong
    Wang, Junjie
    Zhou, Yuan
    APPLIED THERMAL ENGINEERING, 2017, 123 : 234 - 242
  • [10] Performance analysis of a novel oil-free rotary compressor
    Farkas, Balazs
    Suda, Jeno Miklos
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2018, 232 (07) : 870 - 887