Placement standard research of auxiliary probes when measuring ground impedance

被引:0
|
作者
Kim D.-W. [1 ]
Gil H.-J. [1 ]
Kim D.-O. [1 ]
Lee K.-Y. [1 ]
Moon H.-W. [1 ]
机构
[1] University of Florida, Electrical and Computer Engineering
来源
Transactions of the Korean Institute of Electrical Engineers | 2011年 / 60卷 / 10期
关键词
Auxiliary probes; Fall-of-potential; Ground impedance; Placement standard;
D O I
10.5370/KIEE.2011.60.10.1984
中图分类号
学科分类号
摘要
Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.
引用
收藏
页码:1984 / 1991
页数:7
相关论文
共 50 条
  • [31] Theoretical research of measuring planeness by isoclinic interferometric standard ring diameter
    Guangdong Institute of Metrology, Guangzhou 510405, China
    Jiliang Xuebao, 2008, 4 (305-308):
  • [32] Research on Miniaturized and Portable Impedance-measuring Device for Structural Health Monitoring
    Zhang, Yuxiang
    Wen, Dongdong
    Li, Huacheng
    Xu, Fuhou
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY, PTS 1-3, 2011, 230-232 : 587 - 591
  • [33] A New Bioimpedance Research Device (BIRD) for Measuring the Electrical Impedance of Acupuncture Meridians
    Wong, Felix Wu Shun
    Lim, Chi Eung Danforn
    Smith, Warren
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2010, 16 (03) : 257 - 264
  • [35] Research on Fracture Mechanism of High Ground Stress Fracture Rock Tunnel and Auxiliary Construction Measures
    Ding, Fei
    3RD INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, RESOURCE AND ENVIRONMENTAL ENGINEERING (MSREE 2018), 2018, 2036
  • [36] Standard Error Biases When Using Generated Regressors in Accounting Research
    Chen, Wei
    Hribar, Paul
    Melessa, Sam
    JOURNAL OF ACCOUNTING RESEARCH, 2023, 61 (02) : 531 - 569
  • [37] When a Placebo Is Not a Placebo: Problems and Solutions to the Gold Standard in Psychotherapy Research
    Locher, Cosima
    Gaab, Jens
    Blease, Charlotte
    FRONTIERS IN PSYCHOLOGY, 2018, 9
  • [38] A Dynamic Phasor-Based Method for Measuring the Apparent Impedance of a Single-Line-to-Ground Fault
    Yu, Chi-Shan
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2011, E94A (01) : 461 - 463
  • [39] Electrode Placement in Bioimpedance Spectroscopy Evaluation of alternative positioning of electrodes when measuring relative dehydration in athletes
    Birkemose, M.
    Moller, A. J.
    Madsen, M. L.
    Brantlov, S.
    Sorensen, H.
    Overgaard, K.
    Johansen, P.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3028 - 3031
  • [40] Modeling and Research on Grounding Impedance of Large Ground Grid under Complex Geological Conditions
    Ren, Zhangao
    He, Zhiqiang
    Li, Xin
    Wang, Muxue
    Yan, Jiaying
    Song, Xianqi
    Bi, Yueqi
    Yang, Meng
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 92 - 96