Overvoltage and insulation coordination for ±1100 kV UHVDC converter station

被引:0
|
作者
机构
[1] Zhou, Hao
[2] Deng, Xu
[3] Wang, Dongju
[4] Shen, Yang
[5] Chen, Xilei
[6] Sun, Ke
来源
Zhou, H. (zhouhao_ee@zju.edu.cn) | 2013年 / Science Press卷 / 39期
关键词
Power transmission - Electric insulation coordination - Busbars - Electrolysis - Surge protection - Insulation - Transformer protection - Overvoltage protection;
D O I
10.3969/j.issn.1003-6520.2013.10.022
中图分类号
学科分类号
摘要
In order to specify the overvoltage and insulation level of equipments in ±1100 kV UHVDC converter stations, the arrester configuration scheme and some basic parameters for ±1100 kV Zhundong converter station are proposed. Overvoltage of equipments in AC system, valve hall, DC busbar, and neutral busbar are also calculated in accordance with the fundamental principles of arrester configuration for UHV converter stations and the existing experiences in insulation coordination of ±800 kV UHVDC converter stations. The work is done also for specifing insulation levels for ±1100 kV UHVDC converter stations of the ±1100 kV UHVDC power transmission project from Zhundong to Sichuan in China. Thus, the recommended insulation margins that determine the insulation levels of converter station equipments are proposed: the insulation margins for thyristor valves are 10%/10%/15% for switching impulse/lightning impulse/steer front impulse; the insulation levels of lighting and swtiching impulses are recommended as 2600 kV and 2150 kV respectively for 1100 kV DC buses, and as 2250 kV and 2100 kV respectively for equipments at the valve side of high-voltage Y/Y converter transformers.
引用
收藏
相关论文
共 50 条
  • [41] Test on Electromagnetic Transient in An Operating UHVDC Converter Station
    Qiu, Wei
    Huang, Yin
    Zhang, Xiao
    Yu, Zhanqing
    He, Jinliang
    PROCEEDINGS OF 2014 IEEE WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS (WARTIA), 2014, : 1423 - 1425
  • [42] Electric field simulation and optimization of ±1100 kV HVDC converter valve in insulation type test
    Qi, Lei
    Wang, Xingxing
    Li, Chao
    Wang, Gaoyong
    Cui, Xiang
    Gao, Chong
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (04): : 1262 - 1271
  • [43] Study on noise reduce for equipment at UHVDC converter station
    Yang, Yiming
    Zhang, Xuwen
    Gaodianya Jishu/High Voltage Engineering, 2006, 32 (09): : 149 - 152
  • [44] Design and Dielectric Characteristics of the ±1100 kV UHVDC Wall Bushing in China
    Zhang, Shiling
    Peng, Zongren
    Liu, Peng
    Li, Naiyi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 409 - 419
  • [45] Research of ±1100kV UHVDC Project Simplified DC Filter
    Liu Z.
    Yu J.
    Guo X.
    Fu Y.
    Ji Y.
    Liu J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2017, 37 (21): : 6347 - 6352
  • [46] Simulation and Analysis of Operating Overvoltage of AC System at ±800 kV Converter Station Based on EMTS/EMTPE
    Ren, Zheng
    Fan, Jiaqi
    Chen, Xiaolu
    Gao, He
    Lu, Jianqiang
    Zheng, Bowen
    ADVANCES IN ARTIFICIAL SYSTEMS FOR MEDICINE AND EDUCATION II, 2020, 902 : 729 - 737
  • [47] Air clearance design for valve hall of Zhexi ±800 kV UHVDC converter station using parameter g
    Chen, Xi-Lei
    Zhou, Hao
    Wang, Dong-Ju
    Shen, Yang
    Qian, Feng
    Zhou, Zhi-Chao
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (09): : 2185 - 2189
  • [48] Study on the Aging Characteristics of Insulation Oil of UHVDC Converter Transformer
    Liu C.
    Shao S.
    Liao R.
    Yang L.
    Cheng L.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (03): : 730 - 736
  • [49] The peculiarities of insulation coordination in power network with overvoltage arresters
    Markevicius, Linas Andronis
    Navickas, Algimantas
    Stanioniene, Renata
    Daunoras, Jonas
    Ticka, Vidmantas
    PROCEEDINGS OF THE XVII INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DISTURBANCES, EMD 2007, 2007, : 247 - 249
  • [50] Study on working condition of 750 kV AC filter breaker in ± 1100 kV UHVDC system
    Zhao, Zexin
    Guo, Jie
    Yu, Fang
    Rao, Xuni
    Wu, Xiaoke
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 839 - 844