The optimization of the X-ray stress measurement condition on austenitic stainless tubes for electric power plants

被引:0
|
作者
Kurimura, Takayuki [1 ]
Konishi, Takashi [1 ]
机构
[1] Takasago Res. and Development Center, Mitsubishi Heavy Indust., LTD., 2-1-1 Shinhama, Arai-cho, Takasago, Hyogo, 676-8686, Japan
来源
Materials Science Research International | 2002年 / 8卷 / 4 SPEC.期
关键词
Austenite - Electric power plants - Grain size and shape - Mechanical variables measurement - Optimization - Oscillations - Particle beams - Pipe - Stress analysis - X ray diffraction;
D O I
暂无
中图分类号
学科分类号
摘要
Optimization of the rapid X-ray stress measurement method and its condition on large grain austenitic tube steel using a Kα line has been investigated. X-ray residual stress measurements were conducted using several Kα lines on several surface conditions of large grain austenitic tube steel. Using the VKα line, the measurement time can be reduced to one third compared to the CrKβ line. For a rapid measurement, a superimposing procedure of the X-ray diffraction profile from different incident beam angles (superimpose oscillation method) was also employed achieving a similar effect to that of incident beam oscillation. The best measurement condition was discussed using the above superimpose oscillation method that is an effective method for material with a large grain size.
引用
收藏
页码:175 / 180
相关论文
共 50 条
  • [21] Measurement of residual stresses by X-ray diffraction near simulated heat affected zones in austenitic stainless steels
    Iyer, V.S.
    Hendricks, R.W.
    David, S.A.
    Proceedings of the Annual Conference on Applications of X-Ray Analysis, 1991,
  • [22] X-RAY MEASUREMENT OF STACKING-FAULT PARAMETER IN AN AUSTENITIC CR-MN-N STAINLESS STEEL
    KUTUMBARAO, VV
    RAO, PR
    CURRENT SCIENCE, 1968, 37 (24): : 696 - +
  • [23] X-ray diffraction characterization of ion-implanted austenitic stainless steel
    Marques, MJ
    Pina, J
    Dias, AM
    Lebrun, JL
    Feugeas, J
    SURFACE & COATINGS TECHNOLOGY, 2005, 195 (01): : 8 - 16
  • [24] X-ray diffraction Rietveld analysis of cold worked austenitic stainless steel
    Murugesan, S.
    Kuppusami, P.
    Mohandas, E.
    Vijayalakshmi, M.
    MATERIALS LETTERS, 2012, 67 (01) : 173 - 176
  • [25] Study of stacking faults in deformed austenitic stainless steel by x-ray diffraction
    Teng, Feng-En
    Yang, Benwei
    Wang, Yuming
    Metallurgical transactions. A, Physical metallurgy and materials science, 1992, 23 A (10): : 2859 - 2861
  • [26] Optimization of X-ray pole figure measurement
    Tarkowski, L
    Laskosz, L
    Bonarski, JT
    EUROPEAN POWDER DIFFRACTION EPDIC 8, 2004, 443-4 : 137 - 140
  • [27] MEASUREMENT OF INHERENT FILTRATION IN DIAGNOSTIC X-RAY TUBES AND EFFECT OF TARGET ANGLE ON X-RAY QUALITY
    ARDRAN, GM
    CROOKS, HE
    BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (536): : 599 - &
  • [28] MEASUREMENT OF FOCAL SPOT SIZE IN MAMMOGRAPHY X-RAY TUBES
    LAW, J
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (781): : 44 - 50
  • [29] Principle and practice of the x-ray stress measurement
    Ohya, Shin-ichi
    Keikinzoku Yosetsu/Journal of Light Metal Welding and Construction, 2002, 40 (03): : 6 - 17
  • [30] X-RAY DIFFRACTION AND STRESS MEASUREMENT.
    Maeder, Gerard
    Chemica scripta, 1985, 26 A : 23 - 31