The optimization of the X-ray stress measurement condition on austenitic stainless tubes for electric power plants

被引:0
|
作者
Kurimura, Takayuki [1 ]
Konishi, Takashi [1 ]
机构
[1] Takasago Res. and Development Center, Mitsubishi Heavy Indust., LTD., 2-1-1 Shinhama, Arai-cho, Takasago, Hyogo, 676-8686, Japan
来源
Materials Science Research International | 2002年 / 8卷 / 4 SPEC.期
关键词
Austenite - Electric power plants - Grain size and shape - Mechanical variables measurement - Optimization - Oscillations - Particle beams - Pipe - Stress analysis - X ray diffraction;
D O I
暂无
中图分类号
学科分类号
摘要
Optimization of the rapid X-ray stress measurement method and its condition on large grain austenitic tube steel using a Kα line has been investigated. X-ray residual stress measurements were conducted using several Kα lines on several surface conditions of large grain austenitic tube steel. Using the VKα line, the measurement time can be reduced to one third compared to the CrKβ line. For a rapid measurement, a superimposing procedure of the X-ray diffraction profile from different incident beam angles (superimpose oscillation method) was also employed achieving a similar effect to that of incident beam oscillation. The best measurement condition was discussed using the above superimpose oscillation method that is an effective method for material with a large grain size.
引用
收藏
页码:175 / 180
相关论文
共 50 条
  • [1] The optimization of the X-ray stress measurement condition on austenitic stainless tubes for electric power plants
    Kurimura, T
    Konishi, T
    MATERIALS SCIENCE RESEARCH INTERNATIONAL, 2002, 8 (04): : 175 - 180
  • [2] X-Ray Residual Stress Measurement of Austenitic Stainless Steel Based on Fourier Analysis
    Miyazaki, Toshiyuki
    Sasaki, Toshihiko
    NUCLEAR TECHNOLOGY, 2016, 194 (01) : 111 - 116
  • [3] X-ray stress measurement of stainless steel
    Zhang, Yi-Liang
    Liu, Jin-Yan
    Xu, Xue-Dong
    Beijing Gongye Daxue Xuebao/Journal of Beijing University of Technology, 2010, 36 (09): : 1165 - 1173
  • [4] AN X-RAY COUNTER DIFFRACTOMETER DEVICE FOR STRESS MEASUREMENT IN AUSTENITIC STEELS
    DEVARAJAN, N
    ASUNDI, MK
    SOMASUNDARAM, S
    NDT INTERNATIONAL, 1984, 17 (02): : 67 - 72
  • [5] THERMAL STRESS MEASUREMENT OF EXPLOSIVE AUSTENITIC STAINLESS CLAD STEEL WITH X-RAY.
    Kawano, Masakazu
    Ishida, Tuyoshi
    Kamachi, Kazuyoshi
    Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan, 1980, 66 (06): : 702 - 709
  • [6] X-ray fractography studies on austenitic stainless steels
    Rajanna, K
    Pathiraj, B
    Kolster, BH
    ENGINEERING FRACTURE MECHANICS, 1996, 54 (01) : 155 - &
  • [8] The progress of stress on x-ray tubes
    Wehnelt, A
    ANNALEN DER PHYSIK, 1915, 47 (16) : 1112 - 1126
  • [9] X-RAY STRESS DETERMINATION IN AUSTENITIC STEEL
    NEILSON, JHS
    BRITISH JOURNAL OF APPLIED PHYSICS, 1960, 11 (11): : 523 - 523
  • [10] X-ray microtomographic observation of intergranular stress corrosion cracking in sensitised austenitic stainless steel
    Babout, L.
    Marrow, T. J.
    Engelberg, D.
    Withers, P. J.
    MATERIALS SCIENCE AND TECHNOLOGY, 2006, 22 (09) : 1068 - 1075