Resistance-capacitance model of the capillary heat exchanger in subway tunnels

被引:2
|
作者
Tong Z. [1 ]
Wu H. [1 ]
Guan Y. [1 ]
Ji Y. [1 ]
Hu S. [1 ]
机构
[1] School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao
来源
Energy and Built Environment | 2024年 / 5卷 / 01期
基金
中国国家自然科学基金;
关键词
Capillary heat exchanger; Heat pump; Resistance-capacitance model; Subway tunnel;
D O I
10.1016/j.enbenv.2022.07.002
中图分类号
学科分类号
摘要
The subway operation generates a large amount of waste heat, which will lead to a disruption of the underground thermal balance. To remove the heat, a ground source heat pump system adopting capillary net as the front-end heat exchanger can be built in the tunnels to recycle the waste heat and use it for building heating. Different simulation method was used to analyze the heat transfer process in the tunnel and the surrounding rock. The existing simulation method usually takes a long time for calculation and can not be used for a real-time regulation of the system. Based on the concept of thermoelectric analogy, a resistance-capacitance (RC) model was proposed for rapid prediction and analysis on the heat transfer of the capillary net in subway tunnel. The annual thermal response in the tunnel was analyzed, and the influence of the tunnel air temperature and the capillary inlet water temperature was examined using this model. The maximum heat transfer flux of the capillary in summer (release heat) and in winter (extract heat) was 55.27 W/m2 and 38.33 W/m2, respectively. The effect of capillary inlet water temperature was more remarkable than that of the tunnel air temperature on the capillary heat exchange process. © 2022
引用
收藏
页码:1 / 8
页数:7
相关论文
共 50 条
  • [21] A revised capacitance resistance model for large diameter shallow bore ground heat exchanger
    Najib, Antash
    Zarrella, Angelo
    Narayanan, Vinod
    Grant, Peter
    Harrington, Curtis
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [22] Onsite measurement and performance analysis of capillary heat pump system used in subway tunnels
    Tong, Zhen
    Guan, Yiming
    Cao, Tingtao
    Ji, Yongming
    Hu, Songtao
    Liu, Guodan
    Liu, Nan
    Fan, Yujing
    APPLIED THERMAL ENGINEERING, 2022, 204
  • [23] RESISTANCE RECEIVERS IN RESISTANCE-CAPACITANCE FILTER NETWORKS .2.
    HAUG, A
    ARCHIV FUR TECHNISCHES MESSEN UND INDUSTRIELLE MESSTECHNIK, 1971, (427): : 167 - &
  • [24] Validation of a Resistance-Capacitance Model (RCM) for the Design of Latent Thermal Energy Storage
    Guarda, Dario
    Martelletto, Francesca
    Righetti, Giulia
    Doretti, Luca
    Zilio, Claudio
    Mancin, Simone
    14TH IIR CONFERENCE ON PHASE CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING, 2024, : 254 - 261
  • [25] Heat transfer in shallow subway tunnels
    Krasyuk, A. M.
    Lugin, I. V.
    JOURNAL OF MINING SCIENCE, 2008, 44 (06) : 622 - 627
  • [26] Heat transfer in shallow subway tunnels
    A. M. Krasyuk
    I. V. Lugin
    Journal of Mining Science, 2008, 44 : 622 - 627
  • [27] Resistance-Capacitance Gas Sensor Based on Fractal Geometry
    Yang, Taicong
    Tian, Fengchun
    Covington, James A.
    Xu, Feng
    Xu, Yi
    Jiang, Anyan
    Qian, Junhui
    Liu, Ran
    Wang, Zichen
    Huang, Yangfan
    CHEMOSENSORS, 2019, 7 (03)
  • [28] The transient process analyse of the circuit with a resistance-capacitance branch
    Wu Bing
    Wang Jianliang
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 1056 - +
  • [29] DESIGN OF PARALLEL-T RESISTANCE-CAPACITANCE NETWORKS
    OONO, Y
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1955, 43 (05): : 617 - 619
  • [30] NOTE ON A PARALLEL-T RESISTANCE-CAPACITANCE NETWORK
    WOLF, A
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1946, 34 (09): : 659 - 659