Analysis on supply emergency management based on dual-source

被引:0
|
作者
Zhang, Wen-Jie [1 ,2 ]
Luo, Jian-Wen [2 ]
机构
[1] Shanghai Vocational Management College of Trade Union, Shanghai 201415, China
[2] Antai College of Economics and Management, Shanghai Jiaotong University, Shanghai 200052, China
关键词
Civil defense - Disasters - Profitability - Manufacture;
D O I
暂无
中图分类号
学科分类号
摘要
The problem about manufacturer's supply emergency management strategy under emergencies was studied. Based on single-source, the effects of two different strategies including risky dual-source and mixed dual-source on responding to supply disruption risk were analyzed. The optimal ordering decision and expected profit of the manufacturer in two different procurement strategies were compared, and the factors that have the impact on the manufacturer's choice of emergency strategy were analyzed. Finally, some numerical examples were used to demonstrate the impact of supply disruption probability on the procurement decision and expected profit of the manufacturer. It is shown that dual-source strategy is better than single-source in the prevention of the risk of supply disruptions. The total ordered quantity by the manufacturer in mixed dual-source is equal to that of single-source, but less than that of risky dual-source. In the case of mixed dual-source strategy, the manufacturer will increase the use of reliable supplier as the disruption probability increases, even though bear a higher purchase cost.
引用
收藏
页码:454 / 458
相关论文
共 50 条
  • [41] Dual-source backoff for enhancing language models
    Cho, SY
    COMPUTATIONAL AND INFORMATION SCIENCE, PROCEEDINGS, 2004, 3314 : 407 - 412
  • [42] Dual-Source CT in Congenital Heart Disease
    Ruehm, S.
    Lohan, D.
    Krishnam, M.
    Panknin, C.
    Lell, M. M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [43] Noise Reduction in Dual-Source CT Scanning
    Petersilka, M.
    Krauss, B.
    Stierstorfer, K.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [44] Dual-source CT for chest pain assessment
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Becker, Alexander
    Leber, Alexander W.
    Rist, Carsten
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Becker, Christoph R.
    EUROPEAN RADIOLOGY, 2008, 18 (04) : 773 - 780
  • [45] Application of a dual-source Weissenberg type diffractometer
    Borrmann, H.
    Zhang, H.
    Prots, Yu.
    Schmidt, M.
    Schnelle, W.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2004, 60 : S114 - S114
  • [46] STATIONARY PREMIXED FLAMES IN A DUAL-SOURCE SYSTEM
    BREWSTER, ME
    COMBUSTION AND FLAME, 1992, 91 (01) : 99 - 105
  • [47] TOMAHAWK MOVES TOWARD DUAL-SOURCE PRODUCTION
    KOZICHAROW, E
    AVIATION WEEK & SPACE TECHNOLOGY, 1984, 120 (06): : 56 - &
  • [48] Dual-source CT for chest pain assessment
    Thorsten R. C. Johnson
    Konstantin Nikolaou
    Alexander Becker
    Alexander W. Leber
    Carsten Rist
    Bernd J. Wintersperger
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2008, 18 : 773 - 780
  • [49] Fundamentals of Dual-Source Heating Systems.
    Kalischer, Peter
    Elektrowaerme International, 1975, 33 (A4):
  • [50] Analysis of two-plane optimal distance in noncoherent dual-source jamming
    Zhang, Xu-Dong
    Geng, Xiao-Ming
    Xiong, Hua-Gang
    Li, Ping
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2010, 30 (06): : 737 - 740