Applying power quality characteristics of wind turbines for assessing impact on voltage quality

被引:1
|
作者
Tande, John Olav Giæver [1 ]
机构
[1] SINTEF Energy Research, NOR, Trondheim,N-7465, Norway
关键词
Copyrights - Electric power system interconnection - Electric power transmission networks - Electric utilities - Power quality - Quality control - System stability - Wind farm;
D O I
10.1002/we.59
中图分类号
学科分类号
摘要
Injection of wind power into an electric grid affects the voltage quality. As the voltage quality must be within certain limits to comply with utility requirements, the effect should be assessed prior to installation. To assess the effect, knowledge about the electrical characteristics of the wind turbines is needed or else the result could easily be an inappropriate design of the grid connection. The electrical characteristics of wind turbines are manufacturer-specific but not site-specific. This means that, having the actual parameter values for a specific wind turbine, the expected impact of the wind turbine type on voltage quality when deployed at a specific site, possibly as a group of wind turbines, can be calculated. The methodology for this is explained and illustrated by case studies considering a 5 × 750 kW wind farm on a 22 kV distribution feeder. The detailed analysis suggests that the wind farm capacity can be operated at the grid without causing unacceptable voltage quality. For comparison, a simplified design criterion is considered assuming that the wind farm is only allowed to cause a voltage increment of 1%. According to this criterion, only a very limited wind power capacity would be allowed. Measurements confirm, however, the suggestion of the detailed analysis, and it is concluded that a simplified design criterion such as the ‘1% rule’ should not be used for dimensioning the grid connection of wind farms. Rather, this article suggests a systematic approach including assessment of slow voltage variations, flicker, voltage dips and harmonics, possibly supported by more detailed analyses, e.g. system stability if the wind farm is large or the grid is very weak, and impact on grid frequency in systems where wind power covers a high fraction of the load, i.e. most relevant for isolated systems. Copyright © 2002 John Wiley & Sons, Ltd. Copyright © 2002 John Wiley & Sons, Ltd.
引用
收藏
页码:37 / 52
相关论文
共 50 条
  • [1] Impact of wind turbines on voltage quality
    Tande, JOG
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 1158 - 1161
  • [2] Assessment of wind turbines impact on the power quality of autonomous weak grids
    Ladakakos, PD
    Ioannides, MG
    Koulouvari, MI
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 900 - 905
  • [3] Power quality measurements and analisys for wind turbines
    Sanz, M
    Llombart, A
    Bayod, AA
    Mur, J
    IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 1167 - 1172
  • [4] Power Quality in Weak Grids Containing Wind Turbines
    Palu, Ivo
    Agabus, Hannes
    Oidram, Remi
    PQ2008: 2008 POWER QUALITY AND SUPPLY RELIABILITY, CONFERENCE PROCEEDINGS, 2008, : 125 - 130
  • [5] Power Quality Investigation of Grid Connected Wind Turbines
    Nguyen Tung Linh
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2209 - 2213
  • [6] Grid power quality with variable speed wind turbines
    Chen, Z
    Spooner, E
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2001, 16 (02) : 148 - 154
  • [7] Power quality measurement of wind turbines based on matlab
    Wang, Xu
    Mengke, Qilao
    Zhang, Zhanqiang
    Song, Lili
    Jia, Dajiang
    Song, Weimin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (05): : 1387 - 1393
  • [8] Power Quality Assessment of Wind Turbines by Matlab/Simulink
    Su, H. J.
    Huang, H. Y.
    Chang, G. W.
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [9] Power quality measurements performed on a low-voltage grid equipped with two wind turbines
    Chalmers Univ of Technology, Goteborg, Sweden
    IEEE Trans Energy Convers, 3 (601-606):
  • [10] A Sliding Mode Approach to Enhance the Power Quality of Wind Turbines Under Unbalanced Voltage Conditions
    Mohammad Javad Morshed
    Afef Fekih
    IEEE/CAAJournalofAutomaticaSinica, 2019, 6 (02) : 566 - 574