New method for automatic design of intensified shell and tube heat exchanger with twisted-tape insert

被引:0
|
作者
Cui, Yi [1 ]
Li, Mengyuan [1 ]
Yang, Lu [2 ]
Li, Haidong [2 ]
Zhang, Qiqi [2 ]
Chang, Chenglin [2 ,3 ]
Wang, Yufei [1 ]
机构
[1] College of Chemical Engineering, China University of Petroleum, Beijing,102249, China
[2] School of Chemistry and Chemical Engineering, Chongqing University, Chongqing,401331, China
[3] College of Chemical and Biological Engineering, Zhejiang University, Zhejiang, Hangzhou,310027, China
关键词
Chemical industry - Cost reduction - Heat exchangers - Structural dynamics - Trimming;
D O I
10.16085/j.issn.1000-6613.2023-1410
中图分类号
学科分类号
摘要
Shell and tube heat exchangers are the most widely used heat exchangers, and optimizing their design is a crucial research topic. Most existing design methods are based on heuristic methods or commercial solvers, which are slow in solving and can’t guarantee the quality of design solutions. This paper applied set trimming to the automatic design of shell and tube heat exchangers. The outer diameter of tubes, the length of tubes, the diameter of the shell side, the number of tube sides, the pitch of twist-tapes, and the thickness of twist-tapes were defined as discrete variables and input into the program, which automatically output the design results and solutions. The automatic design optimization of shell and tube heat exchangers that intensified with twisted-tape insert was carried out by using single-objective optimization with the minimization heat exchange area, total annualized cost, and net present cost as optimization objectives. By comparison, we find that set trimming could ensure the global optimization of the design solution, and its solving time was very short. It could provide results within 0.5—2s. The results of minimizing the heat transfer area as the objective function showed that set trimming could obtain a smaller heat transfer area, which was reduced by 0.7% compared to the literature value. At the same time, the use of intensification techniques could reduce the heat transfer area. When the heat stream was distributed on the tube side, the technique reduced the heat transfer area by 7.7%, and the tube-side pressure drop increased by 16.9%. When the heat stream was distributed on the shell side, the heat transfer area was reduced by 14.6%, and the tube-side pressure drop increased by 98.7%. The optimization results with the objective of minimizing total annualized cost and net present cost showed that the cost of intensified conditions was lower than that of non-intensified states, and when the heat stream distribution was on the tube side, it was 13.1% lower. When distributed on the shell side, it was 0.57% lower. In addition, the cost of heat exchangers will also be affected by cost parameters. © 2024 Chemical Industry Press Co., Ltd.. All rights reserved.
引用
收藏
页码:4824 / 4832
相关论文
共 50 条
  • [41] Further understanding of twisted tape effects as tube insert for heat transfer enhancement
    Abu-Khader, Mazen M.
    HEAT AND MASS TRANSFER, 2006, 43 (02) : 123 - 134
  • [42] Influence of twisted tape length on the thermal performance of a heat exchanger tube
    Panda, Jyoti Prakash
    Kumar, Bipin
    Kumar, Manoj
    Patil, Anil Kumar
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 83 (06) : 650 - 663
  • [43] Optimization of thermohydraulic performance of tube heat exchanger with L twisted tape
    Shijie, Li
    Zuoqin, Qian
    Qiang, Wang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 145
  • [44] Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube
    Samutpraphut, Boonsong
    Eiamsa-ard, Smith
    Chuwattanakul, Varesa
    Thianpong, Chinaruk
    Maruyama, Naoki
    Hirota, Masafumi
    ENERGY REPORTS, 2023, 9 : 696 - 703
  • [45] HYDRODYNAMIC AND THERMAL PERFORMANCE OF TWISTED TAPE INSERT PROVIDED IN HEAT EXCHANGER TUBES: A REVIEW
    Datt, Ravi
    Kumar, Anil
    Bhist, Mangal Singh
    Kothiyal, Alok Darshan
    Maithani, Rajesh
    FRONTIERS IN HEAT AND MASS TRANSFER, 2019, 12
  • [46] Intensification of convective heat transfer and heat exchanger performance by the combined influence of a twisted tube and twisted tape
    Samruaisin, P.
    Kunlabud, S.
    Kunnarak, K.
    Chuwattanakul, V
    Eiamsa-ard, S.
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [47] TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts
    Eiamsa-ard, S.
    Ketrain, R.
    Chuwattanakul, V.
    INTERNATIONAL CONFERENCE ON NANOMATERIALS AND BIOMATERIALS (ICNB 2017), 2018, 350
  • [48] The experimental study on the heat transfer and friction factor characteristics in tube with a new kind of twisted tape insert
    Man, Changzhong
    Yao, Jinyu
    Wang, Chong
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 75 : 124 - 129
  • [49] Heat transfer enhancement and optimization of a tube fitted with twisted tape in a fin-and-tube heat exchanger
    Zahra Hajabdollahi
    Hassan Hajabdollahi
    Kyung Chun Kim
    Journal of Thermal Analysis and Calorimetry, 2020, 140 : 1015 - 1027
  • [50] Heat transfer enhancement and optimization of a tube fitted with twisted tape in a fin-and-tube heat exchanger
    Hajabdollahi, Zahra
    Hajabdollahi, Hassan
    Kim, Kyung Chun
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (03) : 1015 - 1027