Extraction and compensation for depth-resolved phase error in spectral domain optical coherence tomography

被引:0
|
作者
Zhang, Xianling [1 ,2 ]
Gao, Wanrong [1 ]
Chen, Chaoliang [1 ]
Bian, Haiyi [1 ]
Zhu, Yue [1 ]
机构
[1] School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China
[2] School of Physics and Optoelectronic Engineering, Nanjing University of Information Science and Technology, Nanjing, Jiangsu 210044, China
来源
关键词
Frequency distributions - Medical and biological imaging - Numerical compensation - Phase error compensations - Spectral domain optical coherence tomographies - Spectral-domain optical coherence tomography - Time frequency characteristics - Windowed Fourier transforms;
D O I
10.3788/CJL201441.0204002
中图分类号
学科分类号
摘要
A windowed Fourier transform (WFT) based method is proposed for extracting and compensating depth-resolved phase error in spectral domain optical coherence tomography (SDOCT) system. Firstly, by using a WFT to the interference spectrum of the light from the sample and the reference mirror, the depth-frequency distribution of A-scan of the sample is obtained. Due to the time-frequency characteristics of the WFT, the interference spectra corresponding to different interfaces at different depths are separated. The polynomial fitting for the phase variation of each complex interference spectrum is then performed and the phase errors distribution with the change of depth is obtained. Based on these phase errors, a precise numerical compensation for the phase is carried out. This method can not only be applied for extracting and compensating of depth-resolved dispersion phase error, but also can be used for depth-varied phase error compensation resulted from uneven spectrum sampling in wave-number space. A simulation for dispersion phase error extraction is conducted. Finally, the SDOCT images of the 4-layer cover glasses and fingernail of a volunteer are obtained and then used for phase error extraction with the WFT method. The results demonstrate that the proposed method has the capability of extracting the phase errors with high precision, leading to the improvement of the depth resolution and the image quality after phase error compensation.
引用
收藏
相关论文
共 50 条
  • [21] Depth-resolved photothermal optical coherence tomography by local optical path length change measurement
    Makita, Shuichi
    Hong, Young-Joo
    Li, En
    Yoshiaki, Yasuno
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [22] RECONSTRUCTION OF DEPTH-RESOLVED FIBER ORIENTATIONS IN THE BRAIN WITH POLARIZATION SENSITIVE OPTICAL COHERENCE TOMOGRAPHY
    Wang, H.
    Boas, D.
    Akkin, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 388 - 389
  • [23] Depth-resolved attenuation coefficient estimation for skin cancer assessment with Optical Coherence Tomography
    Real, Eusebio
    Perez Paredes, Gema
    Lopez Higuera, Jose M.
    Conde, Olga M.
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA III, 2019, 11078
  • [24] Extension of depth-resolved reconstruction of attenuation coefficients in optical coherence tomography for slim samples
    Hohmann, Martin
    Lengenfelder, B.
    Kanawade, R.
    Klaempfl, F.
    Schmidt, Michael
    BIOPHOTONICS JAPAN 2015, 2015, 9792
  • [25] Depth-resolved model-based reconstruction of attenuation coefficients in optical coherence tomography
    Vermeer, K. A.
    Mo, J.
    Weda, J. J. A.
    Lemij, H. G.
    de Boer, J. F.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 322 - 337
  • [26] Automated, Depth-Resolved Estimation of the Attenuation Coefficient From Optical Coherence Tomography Data
    Smith, Gennifer T.
    Dwork, Nicholas
    O'Connor, Daniel
    Sikora, Uzair
    Lurie, Kristen L.
    Pauly, John M.
    Ellerbee, Audrey K.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) : 2592 - 2602
  • [27] Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators
    Morozov, A. N.
    Turchin, I. V.
    QUANTUM ELECTRONICS, 2013, 43 (12) : 1165 - 1169
  • [28] An Optimized Depth-Resolved Dispersion Compensation Method in Optical Coherent Tomography Signal Processing
    Zhang, Xi
    Li, Zhongliang
    Nan, Nan
    Wang, Xiangzhao
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2021, 11761
  • [29] Depth extension technique of spectral domain optical coherence tomography
    Shu Y.
    Zhao C.
    Du X.
    He X.
    Zhao H.
    Shi X.
    Ma J.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2024, 53 (04):
  • [30] Depth-Resolved Physiological Response of Retina to Transcorneal Electrical Stimulation Measured With Optical Coherence Tomography
    Sun, Pengcheng
    Li, Qian
    Li, Heng
    Di, Liqing
    Su, Xiaofan
    Chen, Jianpin
    Zheng, Hao
    Chen, Yao
    Zhou, Chuanqing
    Chai, Xinyu
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (05) : 905 - 915