Partial discharge monitoring and locating in substation using multiple sensors in parallel

被引:0
|
作者
Gao, Penglu [1 ]
Hu, Yue [1 ]
Liu, Bin [2 ]
Cao, Lingyu [1 ]
Jiang, Xiuchen [1 ]
Sheng, Gehao [1 ]
机构
[1] Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China
[2] Shandong Weihai Power Supply Company, Weihai 264200, China
关键词
Characteristic time - Detection signal - Insulation diagnosis - Locating algorithm - Maintenance workload - Multiple sensors - Partial discharge monitoring - Substation equipment;
D O I
暂无
中图分类号
学科分类号
摘要
Partial discharge (PD) monitoring is accepted as the most effective means for insulation diagnosis of high voltage power devices, since it can detect PD defects in early time. However, the methods for PD monitoring of substation equipment are mainly oriented to single device, which require to process on every equipment, cause to high cost, and huge maintenance workload. This paper proposed a PD monitoring system that utilizes multiple sensors connected in parallel to a single cable loop to monitoring PD signals originated by devices in substation. The PD signals are detected by the sensors and transmitted around the cable loop in both directions. A characteristic time delay exists between the measured signals on the two channels for all signals entering the cable from sensor, which is used for PD locating. This paper also focused on the structure of the proposed system, the locating algorithm and proved the feasibility of the system by experiment.
引用
收藏
页码:226 / 230
相关论文
共 50 条
  • [21] Localization Method for Multiple Partial Discharge Sources in Air-insulated Substation by Using Plane Intersection Method
    Zhu M.
    Liu Q.
    Wang Y.
    Deng J.
    Zhang G.
    Guo A.
    Zhang, Guanjun (gjzhang@mail.xjtu.edu.cn), 2018, Science Press (44): : 2970 - 2976
  • [22] Partial discharge monitoring in twisted pair using non-intrusive sensors: numerical analysis
    Billard, T.
    Lebey, T.
    Castelan, P.
    Deville, Y.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1286 - 1289
  • [23] Partial discharge monitoring for power transformers using UHF sensors - part 2: Field experience
    Judd, MD
    Yang, L
    Hunter, IBB
    IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (03) : 5 - 13
  • [24] Partial discharge and the measurement in gas insulated substation
    Han, Xiaolian
    Feng, Yunping
    Qiu, Yuchang
    Chen, Jinqing
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 1995, 29 (03): : 30 - 38
  • [25] Locating Stator Coil Dissection Sites Using Partial Discharge Probes
    Levesque, Melanie
    Provencher, Helene
    Hudon, Claude
    Simard, Alexandre
    Cloutier-Rioux, Emilie
    IEEE ELECTRICAL INSULATION MAGAZINE, 2023, 39 (01) : 17 - 25
  • [26] Partial Discharge Source Localization using UHF Sensors
    Gohil, Nidhi J.
    Kundu, Prasanta
    Chowdhury, Anandita
    2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2017, : 208 - 211
  • [27] u High Accuracy Partial Discharge Location in Power Module using Multiple Loop Sensors
    Mitsudome, Hiroshi
    Akinaga, Yuuva
    Kozako, Masahiro
    Hikita, Masayuki
    Ikeda, Yoshinori
    Taniguchi, Katsumi
    Nakamura, Yoko
    Okamoto, Kenji
    2017 IEEE INTERNATIONAL WORKSHOP ON INTEGRATED POWER PACKAGING (IWIPP), 2017,
  • [28] Partial Discharge Localization in Transformers Using UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Ao, P. L.
    Blackburn, T. R.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 64 - 68
  • [29] Application of Magnetic Materials in Inductive Sensors for Partial Discharge Activity Monitoring
    Petras, J.
    Dzmura, J.
    Kurimsky, J.
    Cimbala, R.
    Kolcunova, I
    Dolnik, B.
    Zbojovsky, J.
    ACTA PHYSICA POLONICA A, 2020, 137 (05) : 714 - 716
  • [30] Data Management for parallel partial Discharge Monitoring of large GIS Fields
    Gross, Detlev W.
    Soeller, Markus
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 104 - 107