Uncertainty analysis on free-field reciprocity calibration of measurement microphones for airborne ultrasound

被引:0
|
作者
机构
[1] Takahashi, Hironobu
[2] Horiuchi, Ryuzo
来源
| 1600年 / Acoustical Society of America卷 / 144期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Airborne ultrasound has been used for various purposes, including object detection and pest repellent systems. Recently, it has been used in haptic technology for virtual reality. The safety of exposure to airborne ultrasound has been studied as its use has increased. Although airborne ultrasound cannot be directly perceived by humans, some research has found that exposure to very high sound pressure levels can harm the human body. Thus, quantitative characterization of airborne ultrasound is essential. To contribute to the safe use of airborne ultrasound, this paper established the acoustic standards in Japan in terms of sound pressure from 20 to 100 kHz. This paper evaluates the measurement uncertainty in the free-field reciprocity calibration of quarter-inch condenser microphones, following the document Guide to the Expression of Uncertainty in Measurement, and describes a few significant uncertainty components, such as deviation from the plane sound field. As a result, it is realized that the expanded uncertainty of 0.3-0.7 dB in a frequency range from 20 to 100 kHz. © 2018 Acoustical Society of America.
引用
收藏
相关论文
共 50 条
  • [21] Measurement Uncertainty in Microphone Free-Field Comparison Calibrations
    Garg, N.
    Surendran, P.
    Dhanya, M. P.
    Chandran, A. T.
    Asif, M.
    Singh, M.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2019, 34 (03): : 357 - 369
  • [22] FREE-FIELD RECIPROCITY CALIBRATION IN THE TRANSITION RANGE BETWEEN NEAR-FIELD AND FAR FIELD
    BEISSNER, K
    ACUSTICA, 1980, 46 (02): : 162 - 167
  • [23] Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 kHz
    Zuckerwar, AJ
    Herring, GC
    Elbing, BR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (01): : 320 - 329
  • [24] Measurement Uncertainty in Microphone Free-Field Comparison Calibrations
    N. Garg
    P. Surendran
    M. P. Dhanya
    A. T. Chandran
    M. Asif
    M. Singh
    MAPAN, 2019, 34 : 357 - 369
  • [25] Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 kHz
    Zuckerwar, Allan J.
    Herring, G.C.
    Elbing, Brian R.
    Journal of the Acoustical Society of America, 2006, 119 (01): : 320 - 329
  • [26] Time-selective windowing technique in free-field microphone reciprocity calibration
    Kwon, Hyu-Sang
    Cho, Wan-Ho
    Suh, Sang-Joon
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 134 (01): : 237 - 245
  • [27] Free field calibration of microphones
    West, W
    NATURE, 1938, 142 : 39 - 39
  • [28] Free field calibration of microphones
    King, AJ
    Maguire, CR
    NATURE, 1938, 141 : 1016 - 1016
  • [29] FREE-FIELD CALIBRATION OF EARPHONES
    VILLCHUR, E
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1969, 46 (6P2): : 1527 - &
  • [30] Minimizing the Effects of Reflections by Using a Virtual Pulse Method, for Free-Field Reciprocity Calibration
    Takahashi, H.
    Horiuchi, R.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2012, 27 (04): : 191 - 198