Analysis on aging condition of stator winding insulation of generator based on the moment characteristics of partial discharge

被引:0
|
作者
Zhang, Xiao-Hong [1 ]
Zhang, Liang [1 ]
Yue, Bo [1 ]
Xie, Heng-Kun [1 ]
机构
[1] Xi'an Jiaotong Univ., Xi'an 710049, China
关键词
Aging of materials - Electric generators - Method of moments - Partial discharges - Stators;
D O I
暂无
中图分类号
学科分类号
摘要
The aging mechanism of stator winding insulation of large generator is analyzed. In this paper, the dependence of skewness and kurtosis in the profile of Φ-q and Φ-n characteristic on aging time are investigated by means of PD measurement on model bars subjected different stresses. The skewness in the profile of Φ-q characteristic changes from positive to negative with aging time, which can be considered as a reference of aging course in stator winding insulation of large generator. A new phenomena is found that the maximum number of PD pulse in the profile of Φ-n appear to be at 45° and 135° in unaged specimen, at 0° and 180° in mid-aged specimen, at 90° and 270° in high-aged specimen, which is an important information to realize aging condition in stator winding insulation of large generator.
引用
收藏
页码:94 / 98
相关论文
共 50 条
  • [41] Digital measurement of partial discharges in generator stator bar insulation during aging test
    Jiang, XW
    Wang, ZH
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 322 - 325
  • [42] New estimating techniques for multi-stress aging test of large generator stator winding insulation
    Song, JC
    Yue, B
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 951 - 956
  • [43] Monitoring the Stator Winding Insulation Condition of a large Synchronous Motor
    Berry, Philip J.
    Hamdi, Essam S.
    2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [44] Partial Discharge Characteristics in the Course of Aging within XLPE Insulation
    <AuthorWANG Hongxin~1
    2. School of Electrical Engineering and Automation
    Wuhan University Journal of Natural Sciences, 2006, (02) : 389 - 393
  • [45] Partial discharge - A valuable stator winding evaluation tool
    Maughan, Clyde V.
    Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, 2006, : 388 - 391
  • [46] Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves
    Hao, YP
    Xie, HK
    Wang, GL
    Jia, ZD
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (03) : 539 - 547
  • [47] Study on Multi-factor Aging Characteristics of Stator Insulation for Wind Turbine Generator
    Ding Xiaoxia
    Liu Xuezhong
    Zhang Jianjun
    Zhang Tianlong
    Bai Yonggang
    Ren Wene
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [48] Problems with modern air-cooled generator stator winding insulation
    Griffith, G
    Tucker, S
    Milsom, J
    Stone, G
    IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (06) : 6 - 10
  • [49] Condition Monitoring of Turbine Generator Using Stator Winding Temperature
    Qian, Fang
    Feng, Yutong
    Ling, Jun
    2018 IEEE INTERNATIONAL CONFERENCE ON PROGNOSTICS AND HEALTH MANAGEMENT (ICPHM), 2018,
  • [50] Partial Discharge Modeling of Internal Discharge in Electrical Machine Stator Winding
    Khan, Qasim
    Refaat, Shady S.
    Abu-Rub, Haitham
    Toliyat, Hamid A.
    2020 IEEE KANSAS POWER AND ENERGY CONFERENCE (KPEC), 2020,