Li co-doped NaI:Tl (NaIL™) is a potentially game-changing scintillation material for gamma-ray and neutron dual detection. Li co-doping introduces efficient thermal neutron detection to one of the most well-established gamma-ray scintillators while retaining the favorable scintillation properties of standard NaI:Tl. NaIL exhibits excellent neutron-gamma pulse shape discrimination (PSD) capability with PSD figure of merit between 2 and 4. Simulations show that NaIL detectors with only 1-3% of enriched6Li doping can outperform many existing neutron detection solutions such as standard3He tubes or CLYC scintillator in terms of neutron detection capability. NaIL will be the first spectral gamma-neutron dual mode detector available in large formats, i.e. multi-liter crystal sizes. Saint-Gobain Crystals is actively working on industrialization of this material. Large format NaIL prototype detectors have been fabricated and tested. © 2018 The American Ceramic Society.
引用
收藏
页码:201 / 208
页数:7
相关论文
共 50 条
  • [11] DUAL GE(LI)-DUAL NAI(TI) GAMMA-RAY SPECTROMETER
    BRAUER, FP
    KAYE, JH
    MITZLAFF, WA
    RIECK, HG
    FAGER, JE
    NUCLEAR INSTRUMENTS & METHODS, 1972, 102 (02): : 223 - +
  • [12] SuN: Summing NaI(Tl) gamma-ray detector for capture reaction measurements
    Simon, A.
    Quinn, S. J.
    Spyrou, A.
    Battaglia, A.
    Beskin, I.
    Best, A.
    Bucher, B.
    Couder, M.
    DeYoung, P. A.
    Fang, X.
    Goerres, J.
    Kontos, A.
    Li, Q.
    Liddick, S. N.
    Long, A.
    Lyons, S.
    Padmanabhan, K.
    Peace, J.
    Roberts, A.
    Robertson, D.
    Smith, K.
    Smith, M. K.
    Stech, E.
    Stefanek, B.
    Tan, W. P.
    Tang, X. D.
    Wiescher, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 16 - 21
  • [13] Deconvolution of gamma-ray spectra obtained with NAI(Tl) detector in a water tank
    Rahman, M. Sohelur
    Cho, Gyuseong
    Kang, Bo-Sun
    RADIATION PROTECTION DOSIMETRY, 2009, 135 (03) : 203 - 210
  • [14] A MULTI NAI(TL) DETECTOR ARRAY FOR MEDIUM ENERGY GAMMA-RAY SPECTROSCOPY
    AGARWAL, YK
    BABA, CVK
    CHAKRABARTY, DR
    DATAR, VM
    GOTHE, DA
    JAIN, HC
    ROY, A
    SHARAN, MK
    PRAMANA-JOURNAL OF PHYSICS, 1990, 35 (01): : 49 - 65
  • [15] Hybrid analytical method for calibrating a standard NaI(Tl) gamma-ray scintillation detector using a lateral hexagonal radioactive source
    Badawi, Mohamed S.
    Hamzawy, A.
    Thabet, Abouzeid A.
    AIP ADVANCES, 2022, 12 (06)
  • [16] A multi-detector Nai(Tl) gamma-ray spectrometry system for investigation of neutron induced capture and fission reactions
    Ruskov, I.
    Kopach, Yu. N.
    Skoy, V.
    Hambsch, F. -J.
    Oberstedt, S.
    GAMMA-2 SCIENTIFIC WORKSHOP ON THE EMISSION OF PROMPT GAMMA-RAYS IN FISSION AND RELATED TOPICS, 2014, 59 : 107 - 113
  • [17] Causes of the diurnal variation observed in gamma-ray spectrum using NaI (Tl) detector
    Datar, Gauri
    Vichare, Geeta
    Selvaraj, C.
    Bhaskar, Ankush
    Raghav, Anil
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2020, 207
  • [18] Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector
    Shi, HX
    Chen, BX
    Li, TZ
    Yun, D
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (04) : 517 - 524
  • [19] Utilizing artificial neural networks to convert gamma-ray spectra from NaI(Tl) detectors to HPGe detector gamma-ray spectra
    Saeidi, Zohreh
    Afarideh, Hossein
    Ghergherehchi, Mitra
    Annals of Nuclear Energy, 2024, 200
  • [20] Li2HfBr6 scintillator for neutron and gamma-ray dual detection
    Fujiwara, Chihaya
    Kurosawa, Shunsuke
    Yamaji, Akihiro
    Yoshikawa, Akira
    APPLIED PHYSICS EXPRESS, 2023, 16 (10)