Analysis of influence factors of the total electric field distribution beneath UHVDC power lines

被引:0
|
作者
Lu, Tie-Bing [1 ]
Feng, Han [2 ]
Wang, Qi [3 ]
Cui, Xiang [1 ]
机构
[1] School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, China
[2] Zhengzhou Power Supply Company, Henan Electric Power Company, Zhengzhou 450006, China
[3] Technology Research Center, China Southern Power Grid, Guangzhou 510623, China
来源
关键词
Electric lines - Electric power distribution - Electric corona;
D O I
暂无
中图分类号
学科分类号
摘要
Total electric field should be considered during the design of UHVDC transmission lines as one of the principal environment indices. The upstream finite element method (UFEM) was applied to analyze the total ground electric field and ionic current density distributions under 800 kV UHVDC power lines. The effectiveness of the method was validated, and the Yunguang 800 kV UHVDC power lines were calculated to analyze the influences of the height, line spacing, conductor surface condition, and the polarity. The analysis results show that, increasing the height can reduce the total electric field obviously, but line spacing has little influence on the total electric field. The condition of the conductor surface should be considered to control the total ground electric field.
引用
收藏
页码:2066 / 2070
相关论文
共 50 条
  • [41] Distribution of magnetic field of power lines with different configurations
    Faiz, J.
    Tarafdar-Haque, M.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 300 - +
  • [42] Considerations on the Design of a Low-Power Electric Plant and Analysis of Influence Factors
    Setel, Aurel
    Antal, Cornel
    Bococi, Dana
    Gordan, Mircea
    2015 13TH INTERNATIONAL CONFERENCE ON ENGINEERING OF MODERN ELECTRIC SYSTEMS (EMES), 2015,
  • [43] A probabilistic approach to exposure assessment of power lines electric field
    El Din, EST
    Anis, H
    Abouelsaad, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 887 - 893
  • [44] Analysis of Error Range in Calculation of Load Electric Power Losses in Wires of Overhead Transmission Lines when Neglecting Influence of Meteorological Factors
    Shvedov, G., V
    Shchepotin, A. S.
    2019 INTERNATIONAL URAL CONFERENCE ON ELECTRICAL POWER ENGINEERING (URALCON), 2019, : 368 - 372
  • [45] MEMS Microphone for Acoustic Sensing on Overhead Power Lines: Analysis of Electric and Magnetic Field Interference
    Sattlegger, J.
    Neumayer, M.
    Bretterklieber, T.
    2022 IEEE SENSORS, 2022,
  • [46] Simulation Analysis of Electric Field and Mechanical Stress of Ceramic Supporting Insulator in UHVDC Wall Bushing
    Dong, Hao
    Yang, Zhuodong
    Yang, Xiao
    Lu, Licheng
    Zhang, Yi
    Qi, Bo
    Li, Chengrong
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 407 - 410
  • [48] Influence of Complex Terrains on Electric Field Under Overhead Lines
    Liang, Zhenguang
    Jiang, Yuze
    Hong, Jinge
    2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2018), 2018, : 275 - 279
  • [49] Calculation of Conductors' Surface Electric Field of ±800kV UHVDC Transmission Lines with Optimized Charge Simulation Method
    Hu Qin
    Shu Lichun
    Jiang Xingliang
    Xue Rong
    Yuan Qianfei
    Zhang Shikun
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 362 - +
  • [50] Modeling of the Conductive Loop Method to Mitigate the Magnetic Field Beneath Urban Power Lines
    Pedro Gonzales, S. M.
    2022 IEEE ANDESCON, 2022, : 432 - 438