Prompt Gamma Rays Detected with a BGO Block Compton Camera Reveal Range Deviations of Therapeutic Proton Beams

被引:32
|
作者
Hueso-Gonzalez F. [1 ,2 ]
Pausch G. [1 ,3 ,5 ]
Petzoldt J. [3 ,4 ,5 ]
Romer K.E. [1 ]
Enghardt W. [1 ,5 ,6 ]
机构
[1] Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology, Dresden
[2] Target Systemelektronik GmbH, Wuppertal
[3] OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[4] Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve
[5] University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden
[6] German Cancer Consortium, German Cancer Research Center
来源
| 1600年 / Institute of Electrical and Electronics Engineers Inc.卷 / 01期
基金
欧盟地平线“2020”;
关键词
BGO block detector; Compton camera; prompt gamma ray imaging; proton therapy; range verification;
D O I
10.1109/TNS.2016.2622162
中图分类号
学科分类号
摘要
The dose deposition profile of protons is interesting for tumour treatment due to the increased ionization density at the end of their track. However, the inaccurate knowledge of the proton stopping point limits the precision of the therapy. Prompt gamma rays, a by-product of the irradiation, are candidates for an indirect measurement of the particle range. Compton cameras have been proposed for prompt gamma ray imaging, but struggle with high trigger rates and low coincident efficiency. The feasibility in a clinical environment has yet to be proved. At Universitäts Protonen Therapie Dresden, two bismuth germanate (BGO) block detectors arranged face-to-face are deployed for imaging tests with a homogeneous target irradiated by a proton pencil beam. Shifts of the target, increase of its thickness and beam energy variation experiments are conducted. Each measurement lasts about 15 minutes at a low proton beam current. The effect of one centimetre proton range deviations on the backprojected images is analysed. The number of valid Compton events as well as the trigger rate expected in a realistic treatment plan with pencil beam scanning are estimated. The results support the use of a high density material despite its moderate energy resolution, in order to maximize the coincident efficiency. Nevertheless, they discourage the applicability of a two-plane Compton camera in a clinical scenario with usual beam currents. © 2017 IEEE.
引用
收藏
页码:76 / 86
页数:10
相关论文
共 50 条
  • [41] Optimization of Collimator Designs for Real-Time Proton Range Verification by Measuring Prompt Gamma Rays
    Cambraia Lopes, P.
    Pinto, M.
    Simoes, H.
    Biegun, A. K.
    Dendooven, P.
    Oxley, D. C.
    Parodi, K.
    Schaart, D. R.
    Crespo, P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3864 - 3870
  • [42] Energy- and time-resolved detection of prompt gamma-rays for proton range verification
    Verburg, Joost M.
    Riley, Kent
    Bortfeld, Thomas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20): : L37 - L49
  • [43] New algorithm to estimate proton beam range for multi-slit prompt- gamma camera
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3422 - 3428
  • [44] Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
    Nenoff, Lena
    Priegnitz, Marlen
    Janssens, Guillaume
    Petzoldt, Johannes
    Wohlfahrt, Patrick
    Trezza, Anna
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 534 - 540
  • [45] Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiaition: Initial Studies
    Polf, J.
    Brown, S.
    Mann, J.
    Mackin, D.
    Zheng, Y.
    McCleskey, M.
    Beddar, S.
    He, Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 183 - 183
  • [46] The Effects of Compton Camera Data Acquisition Timing and Readout On Prompt Gamma Images Acquired at Clinical Proton Beam Dose Rates
    Polf, J.
    Maggi, P.
    Panthi, R.
    Mackin, D.
    Peterson, S.
    Beddar, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [47] Hybrid treatment verification based on prompt gamma rays and fast neutrons: multivariate modelling for proton range determination
    Schellhammer, Sonja M.
    Meric, Ilker
    Loeck, Steffen
    Koegler, Toni
    FRONTIERS IN PHYSICS, 2023, 11
  • [48] Validation of Nuclear Reaction Models to Simulate Proton Therapy Range Verification Using Prompt Gamma-Rays
    Verburg, J.
    Shih, H.
    Seco, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3860 - 3860
  • [49] First Demonstration of a Prompt Gamma Slit-Camera for in Vivo Proton Range Verification Based On Semiconductor Detectors
    Wang, H.
    Lu, Y.
    Kuang, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E509 - E509
  • [50] REAL-TIME PROTON BEAM RANGE MONITORING BY MEANS OF PROMPT-GAMMA DETECTION WITH A COLLIMATED CAMERA
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Prieels, D.
    Ray, C.
    Richard, M. H.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S120 - S121